DFFA8DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2, Standard Material/Coating
Part number: DFFA8DN · DFFA8-DN · DFFA8 DN
2-way, poppet directional valve with integral T-8A control cavity – control 1-2. Cavity T-18A, capacity 120 gpm (480 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.
DFFA8-DN overview
DFFA8DN (DFFA8-DN, DFFA8 DN) is a Sun Hydraulics Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2, rated 120 gpm (480 L/min.) and installed in cavity T-18A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.
Ordering codes
Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.
| DFFA8DN/AP | Stainless Steel, PassivatedStainless Steel, Passivated |
|---|---|
| DFFA8DN | Standard Material/CoatingStandard Material/Coating |
Specifications
| Cavity | T-18A |
|---|---|
| Series | 4 |
| Capacity | 120 gpm (480 L/min.) |
| Maximum Operating Pressure | 5000 psi (350 bar) |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 10 drops/min.@5000 psi (0,7 cc/min.@350 bar) |
| Pilot Control Cavity | T-8A |
| Pilot Control Valve Installation Torque | 20 - 25 lbf ft (27 - 33 Nm) |
| Valve Hex Size | 1 5/8 in. (41,3 mm) |
| Valve Installation Torque | 350 - 375 lbf ft (474 - 508 Nm) |
| Model Weight | 1.10 lb (0,50 kg) |
| Seal kit - Cartridge | Viton: 990018006 |
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at point of use.
How to read DFFA8DN
Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so DFFA8DN, DFFA8-DN, DFFA8 DN are the same part.
| Model | DFFA8 — Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2 |
|---|---|
| Cracking Pressure | D — 50 psi (3,5 bar) |
| Seal Material | N — Buna-N |
| Material / coating | Add /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish. |
Cracking Pressure options
- D — 50 psi (3,5 bar)
Seal Material options
- N — Buna-N
- V — Viton
- E — EPDM
Material/coating options
- /AP — Stainless Steel, Passivated
- — Standard Material/Coating
Manifold & standard assemblies
Sun manifolds for cavity T-18A (102)
- LA2 Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LA2 — request assembly
- LA4 Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LA4 — request assembly
- LA5 Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LA5 — request assembly
- LA6 Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LA6 — request assembly
- LA7 Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LA7 — request assembly
- LA8 Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LA8 — request assembly
- LA9 Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LA9 — request assembly
- LAD Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LAD — request assembly
- LAE Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LAE — request assembly
- LAF Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LAF — request assembly
- LAL Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LAL — request assembly
- LAM Sun Hydraulics Ninety degree with gauge port Line mount manifoldDFFA8DN-LAM — request assembly
Technical features
- NOTE: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
- The -8 control option allows the pilot control valve to be incorporated directly into the end of the directional cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include solenoid operation, air pilot operation, and hydraulic pilot operation. See Pilot Control Cartridges.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Drawings, symbol & performance curves
Downloads
Datasheet
Technical reference sheets
CAD files
Frequently asked questions
Is DFFA8DN the same as DFFA8-DN?
Yes. Sun Hydraulics writes this part number as DFFA8DN. It is the model DFFA8 followed by the configuration code; hyphens, slashes and spaces are only dividers, so DFFA8DN, DFFA8-DN, DFFA8 DN all refer to the same product.
Do you supply DFFA8DN in the UAE, GCC and India?
Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including DFFA8DN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.
Can I get the datasheet and CAD files?
Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.
How big is a drop of hydraulic oil?
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Direct acting or pilot operated - what do I use?
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
What parts of the Sun cartridge valve are field serviceable?
Manufacturer reference: https://www.sunhydraulics.com/model/DFFA8