DFFI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve – flow 1-2 (740 Series)

Part number: DFFIXCN · DFFI-XCN · DFFI XCN

Brand Sun HydraulicsType 2-wayCapacity 120 gpm (480 L/min.)Cavity T-18A

2-way, 2-stage, solenoid-operated directional poppet valve – flow 1-2 (740 Series). Cavity T-18A, capacity 120 gpm (480 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: DFFI Category: Brand:

DFFI-XCN overview

DFFIXCN (DFFI-XCN, DFFI XCN) is a Sun Hydraulics Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series), rated 120 gpm (480 L/min.) and installed in cavity T-18A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

DFFIXCN No coilNo coil
DFFIXCN211 DIN 43650-Form A, 115 VACDIN 43650-Form A, 115 VAC
DFFIXCN212 DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC
DFFIXCN212D DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodesDIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes

Specifications

CavityT-18A
Series4
Capacity120 gpm (480 L/min.)
Maximum Operating Pressure5000 psi (350 bar)
Maximum Valve Leakage at 110 SUS (24 cSt)10 drops/min.@5000 psi (0,7 cc/min.@350 bar)
Check Cracking Pressure50 psi (3,5 bar)
Response Time - Typical30 ms
Switching Frequency15,000 max. cycles/hr
Solenoid Tube Diameter.63 in. (16 mm)
Valve Hex Size1 5/8 in. (41,3 mm)
Valve Installation Torque350 - 375 lbf ft (474 - 508 Nm)
Model Weight2.80 lb (1,30 kg)
Seal kit - CartridgeViton: 990018006

How to read DFFIXCN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so DFFIXCN, DFFI-XCN, DFFI XCN are the same part.

ModelDFFI — Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series)
ControlX — No Manual Override
Poppet ConfigurationC — Normally Closed
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Control options
  • D — Twist/Lock (Dual) Manual Override
  • L — Twist/Lock (Detent) Manual Override
  • M — Manual Override
  • T — Twist (Momentary) Manual Override
  • X — No Manual Override
Poppet Configuration options
  • C — Normally Closed
  • H — Normally Open
Seal Material options
  • N — Buna-N
  • V — Viton
  • E — EPDM
Coil options
  • — No coil
  • 211 — DIN 43650-Form A, 115 VAC
  • 212 — DIN 43650-Form A, 12 VDC
  • 212D — DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes
  • 212X01 — DIN 43650-Form A, 12 VDC, with XMD-01 driver
  • 212X02 — DIN 43650-Form A, 12 VDC, with XMD-02 driver
  • 214 — DIN 43650-Form A, 14 VDC
  • 214D — DIN 43650-Form A, 14 VDC, with transient voltage suppression (TVS) diodes
  • 214X01 — DIN 43650-Form A, 14 VDC, with XMD-01 driver
  • 214X02 — DIN 43650-Form A, 14 VDC, with XMD-02 driver
  • 223 — DIN 43650-Form A, 230 VAC
  • 224 — DIN 43650-Form A, 24 VDC
  • 224D — DIN 43650-Form A, 24 VDC, with transient voltage suppression (TVS) diodes
  • 224X01 — DIN 43650-Form A, 24 VDC, with XMD-01 driver
  • 224X02 — DIN 43650-Form A, 24 VDC, with XMD-02 driver
  • 228 — DIN 43650-Form A, 28 VDC
  • 228D — DIN 43650-Form A, 28 VDC, with transient voltage suppression (TVS) diodes
  • 228X01 — DIN 43650-Form A, 28 VDC, with XMD-01 driver
  • 228X02 — DIN 43650-Form A, 28 VDC, with XMD-02 driver
  • 612 — AMP Junior Timer, 12 VDC
  • 612D — AMP Junior Timer, 12 VDC, with transient voltage suppression (TVS) diodes
  • 614 — AMP Junior Timer, 14 VDC
  • 614D — AMP Junior Timer, 14 VDC, with transient voltage suppression (TVS) diodes
  • 624 — AMP Junior Timer, 24 VDC
  • 624D — AMP Junior Timer, 24 VDC, with transient voltage suppression (TVS) diodes
  • 628 — AMP Junior Timer, 28 VDC
  • 628D — AMP Junior Timer, 28 VDC, with transient voltage suppression (TVS) diodes
  • 712 — Twin Lead, 12 VDC
  • 712D — Twin Lead, 12 VDC, with transient voltage suppression (TVS) diodes
  • 714 — Twin Lead, 14 VDC
  • 714D — Twin Lead, 14 VDC, with transient voltage suppression (TVS) diodes
  • 724 — Twin Lead, 24 VDC
  • 724D — Twin Lead, 24 VDC, with transient voltage suppression (TVS) diodes
  • 728 — Twin Lead, 28 VDC
  • 728D — Twin Lead, 28 VDC, with transient voltage suppression (TVS) diodes
  • 812 — Metri-Pack, 12 VDC
  • 812D — Metri-Pack, 12 VDC, with transient voltage suppression (TVS) diodes
  • 814 — Metri-Pack, 14 VDC
  • 814D — Metri-Pack, 14 VDC, with transient voltage suppression (TVS) diodes
  • 824 — Metri-Pack, 24 VDC
  • 824D — Metri-Pack, 24 VDC, with transient voltage suppression (TVS) diodes
  • 828 — Metri-Pack, 28 VDC
  • 828D — Metri-Pack, 28 VDC, with transient voltage suppression (TVS) diodes
  • 912 — Deutsch DT04-2P, 12 VDC
  • 912D — Deutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodes
  • 912X01 — Deutsch DT04-2P, 12 VDC, with XMD-01 driver
  • 912X02 — Deutsch DT04-2P, 12 VDC, with XMD-02 driver
  • 914 — Deutsch DT04-2P, 14 VDC
  • 914D — Deutsch DT04-2P, 14 VDC, with transient voltage suppression (TVS) diodes
  • 914X01 — Deutsch DT04-2P, 14 VDC, with XMD-01 driver
  • 914X02 — Deutsch DT04-2P, 14 VDC, with XMD-02 driver
  • 924 — Deutsch DT04-2P, 24 VDC
  • 924D — Deutsch DT04-2P, 24 VDC, with transient voltage suppression (TVS) diodes
  • 924X01 — Deutsch DT04-2P, 24 VDC, with XMD-01 driver
  • 924X02 — Deutsch DT04-2P, 24 VDC, with XMD-02 driver
  • 928 — Deutsch DT04-2P, 28 VDC
  • 928D — Deutsch DT04-2P, 28 VDC, with transient voltage suppression (TVS) diodes
  • 928X01 — Deutsch DT04-2P, 28 VDC, with XMD-01 driver
  • 928X02 — Deutsch DT04-2P, 28 VDC, with XMD-02 driver
  • JM24BD — Explosion Proof, Metric (M20 X 1.5), 24 VDC, 180 Degree, CSA and ATEX Certification
  • JM24CD — Explosion Proof, Metric (M20 X 1.5), 24 VDC, 90 Degree, CSA and ATEX Certification
  • JN24BD — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 180 Degree, CSA and ATEX Certification
  • JN24CD — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 90 Degree, CSA and ATEX Certification

Manifold & standard assemblies

Sun manifolds for cavity T-18A (102)

View all 102 →

Technical features

  • The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
  • This cartridge has an option for manual override. See the CONFIGURATION section.
  • Valves exhibit extremely low leakage rates; less than 10 drops/min. @ 5000 psi (0,7 cc/min @ 350 bar).
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • The solenoid's unique magnetic design results in a high efficiency solenoid, yielding high spool actuating force per Watt expended, leading to reliable valve shifting.
  • Coils can be mounted on the tube in either direction.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Drawings, symbol & performance curves

DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFFI-XCN Sun Hydraulics 2-way Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
DFFIXCN Sun Hydraulics 2-way Valve – 2D outline drawing
2D outline drawing

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is DFFIXCN the same as DFFI-XCN?

Yes. Sun Hydraulics writes this part number as DFFIXCN. It is the model DFFI followed by the configuration code; hyphens, slashes and spaces are only dividers, so DFFIXCN, DFFI-XCN, DFFI XCN all refer to the same product.

Do you supply DFFIXCN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including DFFIXCN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct acting or pilot operated - what do I use?

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

Manufacturer reference: https://www.sunhydraulics.com/model/DFFI

See It Styled On Instagram

    No access token

Main Menu