FPJP-XGN – Sun Hydraulics Pilot-operated, normally closed, electro-proportional throttle with reverse flow check – (740 Series)
Part number: FPJPXGN · FPJP-XGN · FPJP XGN
Pilot-operated, normally closed, electro-proportional throttle with reverse flow check – (740 Series). Cavity T-18A, capacity 114 gpm (431 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.
FPJP-XGN overview
FPJPXGN (FPJP-XGN, FPJP XGN) is a Sun Hydraulics Sun Hydraulics Pilot-operated, normally closed, electro-proportional throttle with reverse flow check - (740 Series), rated 114 gpm (431 L/min.) and installed in cavity T-18A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.
Ordering codes
Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.
| FPJPXGN | No coilNo coil |
|---|---|
| FPJPXGN211 | DIN 43650-Form A, 115 VACDIN 43650-Form A, 115 VAC |
| FPJPXGN212 | DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC |
| FPJPXGN212D | DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodesDIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes |
Specifications
| Cavity | T-18A |
|---|---|
| Series | 4 |
| Capacity | 114 gpm (431 L/min.) |
| Maximum Operating Pressure | 5000 psi (350 bar) |
| Recommended dither frequency | 140 Hz |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 20 drops/min.@5000 psi |
| Deadband, nominal (as a percentage of input) | 25% |
| Valve Hex Size | 1 5/8 in. (41,3 mm) |
| Valve Installation Torque | 350 - 375 lbf ft (474 - 508 Nm) |
| Model Weight | 2.36 lb |
| Seal kit - Cartridge | Viton: 990018006 |
| Seal and nut kit - Coil | Viton: 990740006 |
How to read FPJPXGN
Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so FPJPXGN, FPJP-XGN, FPJP XGN are the same part.
| Model | FPJP — Sun Hydraulics Pilot-operated, normally closed, electro-proportional throttle with reverse flow check - (740 Series) |
|---|---|
| Control | X — - |
| Flow Rate | G — Nominal 120 gpm @ 200 psi (14 bar) differential (480 L/min.) |
| Seal Material | N — Buna-N |
| Material / coating | Add /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish. |
Control options
- X — -
Flow Rate options
- B — Nominal 60 gpm @ 200 psi ( 14 bar) differential (240 L/min.)
- D — Nominal 80 gpm @ 200 psi (14 bar) differential (320 L/min.)
- G — Nominal 120 gpm @ 200 psi (14 bar) differential (480 L/min.)
Seal Material options
- N — Buna-N
- V — Viton
Coil options
- — No coil
- 211 — DIN 43650-Form A, 115 VAC
- 212 — DIN 43650-Form A, 12 VDC
- 212D — DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes
- 212X01 — DIN 43650-Form A, 12 VDC, with XMD-01 driver
- 212X02 — DIN 43650-Form A, 12 VDC, with XMD-02 driver
- 214 — DIN 43650-Form A, 14 VDC
- 214D — DIN 43650-Form A, 14 VDC, with transient voltage suppression (TVS) diodes
- 214X01 — DIN 43650-Form A, 14 VDC, with XMD-01 driver
- 214X02 — DIN 43650-Form A, 14 VDC, with XMD-02 driver
- 223 — DIN 43650-Form A, 230 VAC
- 224 — DIN 43650-Form A, 24 VDC
- 224D — DIN 43650-Form A, 24 VDC, with transient voltage suppression (TVS) diodes
- 224X01 — DIN 43650-Form A, 24 VDC, with XMD-01 driver
- 224X02 — DIN 43650-Form A, 24 VDC, with XMD-02 driver
- 228 — DIN 43650-Form A, 28 VDC
- 228D — DIN 43650-Form A, 28 VDC, with transient voltage suppression (TVS) diodes
- 228X01 — DIN 43650-Form A, 28 VDC, with XMD-01 driver
- 228X02 — DIN 43650-Form A, 28 VDC, with XMD-02 driver
- 612 — AMP Junior Timer, 12 VDC
- 612D — AMP Junior Timer, 12 VDC, with transient voltage suppression (TVS) diodes
- 614 — AMP Junior Timer, 14 VDC
- 614D — AMP Junior Timer, 14 VDC, with transient voltage suppression (TVS) diodes
- 624 — AMP Junior Timer, 24 VDC
- 624D — AMP Junior Timer, 24 VDC, with transient voltage suppression (TVS) diodes
- 628 — AMP Junior Timer, 28 VDC
- 628D — AMP Junior Timer, 28 VDC, with transient voltage suppression (TVS) diodes
- 712 — Twin Lead, 12 VDC
- 712D — Twin Lead, 12 VDC, with transient voltage suppression (TVS) diodes
- 714 — Twin Lead, 14 VDC
- 714D — Twin Lead, 14 VDC, with transient voltage suppression (TVS) diodes
- 724 — Twin Lead, 24 VDC
- 724D — Twin Lead, 24 VDC, with transient voltage suppression (TVS) diodes
- 728 — Twin Lead, 28 VDC
- 728D — Twin Lead, 28 VDC, with transient voltage suppression (TVS) diodes
- 812 — Metri-Pack, 12 VDC
- 812D — Metri-Pack, 12 VDC, with transient voltage suppression (TVS) diodes
- 814 — Metri-Pack, 14 VDC
- 814D — Metri-Pack, 14 VDC, with transient voltage suppression (TVS) diodes
- 824 — Metri-Pack, 24 VDC
- 824D — Metri-Pack, 24 VDC, with transient voltage suppression (TVS) diodes
- 828 — Metri-Pack, 28 VDC
- 828D — Metri-Pack, 28 VDC, with transient voltage suppression (TVS) diodes
- 912 — Deutsch DT04-2P, 12 VDC
- 912D — Deutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodes
- 912X01 — Deutsch DT04-2P, 12 VDC, with XMD-01 driver
- 912X02 — Deutsch DT04-2P, 12 VDC, with XMD-02 driver
- 914 — Deutsch DT04-2P, 14 VDC
- 914D — Deutsch DT04-2P, 14 VDC, with transient voltage suppression (TVS) diodes
- 914X01 — Deutsch DT04-2P, 14 VDC, with XMD-01 driver
- 914X02 — Deutsch DT04-2P, 14 VDC, with XMD-02 driver
- 924 — Deutsch DT04-2P, 24 VDC
- 924D — Deutsch DT04-2P, 24 VDC, with transient voltage suppression (TVS) diodes
- 924X01 — Deutsch DT04-2P, 24 VDC, with XMD-01 driver
- 924X02 — Deutsch DT04-2P, 24 VDC, with XMD-02 driver
- 928 — Deutsch DT04-2P, 28 VDC
- 928D — Deutsch DT04-2P, 28 VDC, with transient voltage suppression (TVS) diodes
- 928X01 — Deutsch DT04-2P, 28 VDC, with XMD-01 driver
- 928X02 — Deutsch DT04-2P, 28 VDC, with XMD-02 driver
- JM24BD — Explosion Proof, Metric (M20 X 1.5), 24 VDC, 180 Degree, CSA and ATEX Certification
- JM24CD — Explosion Proof, Metric (M20 X 1.5), 24 VDC, 90 Degree, CSA and ATEX Certification
- JN24BD — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 180 Degree, CSA and ATEX Certification
- JN24CD — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 90 Degree, CSA and ATEX Certification
Manifold & standard assemblies
Sun manifolds for cavity T-18A (102)
- LA2 Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LA2 — request assembly
- LA4 Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LA4 — request assembly
- LA5 Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LA5 — request assembly
- LA6 Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LA6 — request assembly
- LA7 Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LA7 — request assembly
- LA8 Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LA8 — request assembly
- LA9 Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LA9 — request assembly
- LAD Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LAD — request assembly
- LAE Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LAE — request assembly
- LAF Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LAF — request assembly
- LAL Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LAL — request assembly
- LAM Sun Hydraulics Ninety degree with gauge port Line mount manifoldFPJPXGN-LAM — request assembly
Technical features
- Capable of operating with pressures up to 5000 psi (350 bar).
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Capacities rated at 200 psi (14 bar) differential and maximum rated coil current.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves.
- Depending on circuit requirements, a reverse free flow check bypassing the compensator may be needed when using the FPJP with an external compensator.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Drawings, symbol & performance curves
Downloads
Datasheet
Technical reference sheets
- 999-901-334 (PDF 344 KB)
- FloatingStyleScrewInCartridge2 (PDF 1 MB)
- TT_US_Amplifier-New (PDF 2 MB)
- TT_US_Cavity-New (PDF 522 KB)
- TT_US_coils-New (PDF 975 KB)
- rel-Prop_terms-definitionsN (PDF 3 MB)
CAD files
Frequently asked questions
Is FPJPXGN the same as FPJP-XGN?
Yes. Sun Hydraulics writes this part number as FPJPXGN. It is the model FPJP followed by the configuration code; hyphens, slashes and spaces are only dividers, so FPJPXGN, FPJP-XGN, FPJP XGN all refer to the same product.
Do you supply FPJPXGN in the UAE, GCC and India?
Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including FPJPXGN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.
Can I get the datasheet and CAD files?
Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.
What is the pressure drop through a flow control?
In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.
How accurate are Sun's flow controls?
We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.
I have a heat problem, will Sun's priority flow control help?
I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.
What happens if I block the control flow (priority) port?
All flow is blocked, hence the term priority. The priority flow has to be satisfied.
What happens if I block the bypass port on a priority flow control?
The valve acts as a 2 port restrictive flow control.
What is the compensating pressure of Sun's flow controls?
The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.
How big is a drop of hydraulic oil?
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
What parts of the Sun cartridge valve are field serviceable?
Manufacturer reference: https://www.sunhydraulics.com/model/FPJP











