ZKE/S4 – Sun Hydraulics Flange mount through port Line mount manifold, ductile iron, black oxide finish, Buna-N seals

Part number: ZKE · ZKE/10 · ZKE/11 · ZKE/15 · ZKE/16 · ZKE/V · ZKE/S · ZKE/S3 · ZKE/S4 · ZKE/S5 · ZKE/Y · ZKE/Y1 · ZKE/Y3 · ZKE/Y4 · ZKE/Y5

Brand Sun HydraulicsType Line mountCavity T-3A

Flange mount through port Line mount manifold, cavity T-3A, 1 1/4″ Code 61 ports. Genuine Sun Hydraulics — MultiFlow is an authorized distributor.

Clear
SKU: ZKE Category: Brand:

ZKE overview

ZKE (ZKE/10, ZKE/11, ZKE/15, ZKE/16) is a Sun Hydraulics Sun Hydraulics Flange mount through port Line mount manifold and installed in cavity T-3A. MultiFlow supplies genuine Sun Hydraulics manifolds in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

ZKE Aluminium, Buna-N seals6061-T651 Aluminum, Buna-N
ZKE/10 Black anodized aluminium, Buna-N seals6061-T651 Aluminum, Buna-N, Black Anodize - Per MIL SPEC 8625F Type II, Class II
ZKE/11 Clear anodized aluminium, Buna-N seals6061-T651 Aluminum, Buna-N, Clear Anodize - Per MIL SPEC 8625F Type II, Class I
ZKE/15 Black anodized aluminium, Viton seals6061-T651 Aluminum, Viton, Black Anodize - Per MIL SPEC 8625F Type II, Class II
ZKE/16 Clear anodized aluminium, Viton seals6061-T651 Aluminum, Viton, Clear Anodize - Per MIL SPEC 8625F Type II, Class I
ZKE/V Aluminium, Viton seals6061-T651 Aluminum, Viton
ZKE/S Ductile iron, dewatering-oil finish, Buna-N seals65-45-12 Ductile Iron, Buna-N, Dewatering Oil
ZKE/S3 Clear zinc plated ductile iron, Buna-N seals65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
ZKE/S4 Ductile iron, black oxide finish, Buna-N seals65-45-12 Ductile Iron, Buna-N, Chem. Black
ZKE/S5 Electroless nickel plated ductile iron, Buna-N seals65-45-12 Ductile Iron, Buna-N, Electroless Nickel
ZKE/Y Ductile iron, dewatering-oil finish, Viton seals65-45-12 Ductile Iron, Viton, Dewatering Oil
ZKE/Y1 Ductile iron, Clear Zinc Nickel with Top Sealer, Viton seals65-45-12 Ductile Iron, Viton, Clear Zinc Nickel with Top Sealer
ZKE/Y3 Clear zinc plated ductile iron, Viton seals65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
ZKE/Y4 Ductile iron, black oxide finish, Viton seals65-45-12 Ductile Iron, Viton, Chem. Black
ZKE/Y5 Electroless nickel plated ductile iron, Viton seals65-45-12 Ductile Iron, Viton, Electroless Nickel

Specifications

Body TypeLine mount
Interface1.25 SAE C61
Body FeaturesFlange mount through port
Mounting Hole Diameter.47 in. (12 mm)
Mounting Hole C'bore Diameter.69 in. (17,5 mm)
Mounting Hole C'bore Depth.41 in. (10,4 mm)
Mounting Hole Quantity4
Open Cavities1
CavityT-3A
Port Size1 1/4" Code 61

Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.

How to read ZKE

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so ZKE, ZKE/10, ZKE/11, ZKE/15, ZKE/16, ZKE/V, ZKE/S, ZKE/S3, ZKE/S4, ZKE/S5, ZKE/Y, ZKE/Y1, ZKE/Y3, ZKE/Y4, ZKE/Y5 are the same part.

ModelZKE — Sun Hydraulics Flange mount through port Line mount manifold
ModifierAdd the modifier after the model, e.g. ZKE/10 = black anodized aluminium. No modifier = standard material.
Modifier options
  • — 6061-T651 Aluminum, Buna-N
  • /10 — 6061-T651 Aluminum, Buna-N, Black Anodize - Per MIL SPEC 8625F Type II, Class II
  • /11 — 6061-T651 Aluminum, Buna-N, Clear Anodize - Per MIL SPEC 8625F Type II, Class I
  • /15 — 6061-T651 Aluminum, Viton, Black Anodize - Per MIL SPEC 8625F Type II, Class II
  • /16 — 6061-T651 Aluminum, Viton, Clear Anodize - Per MIL SPEC 8625F Type II, Class I
  • /V — 6061-T651 Aluminum, Viton
  • /S — 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
  • /S3 — 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
  • /S4 — 65-45-12 Ductile Iron, Buna-N, Chem. Black
  • /S5 — 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
  • /Y — 65-45-12 Ductile Iron, Viton, Dewatering Oil
  • /Y1 — 65-45-12 Ductile Iron, Viton, Clear Zinc Nickel with Top Sealer
  • /Y3 — 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
  • /Y4 — 65-45-12 Ductile Iron, Viton, Chem. Black
  • /Y5 — 65-45-12 Ductile Iron, Viton, Electroless Nickel

Cartridges that fit this manifold

Sun cartridges for cavity T-3A (16)

View all 16 →

Ports

Modifiers Ports ZKE, /10, /11, /15, /16, /S, /S3, /V, /Y, /Y3 Flange Port 1: 1 1/4" Code 61; Threaded Ports 1 & 2: SAE 16; Gage Port: 1/4" NPTF;

Drawings, symbol & performance curves

ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing
ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing

Downloads

CAD files (from Sun Hydraulics)

Frequently asked questions

Is ZKE the same as ZKE/10?

Yes. Sun Hydraulics writes this part number as ZKE. It is the model ZKE followed by the configuration code; hyphens, slashes and spaces are only dividers, so ZKE, ZKE/10, ZKE/11, ZKE/15, ZKE/16, ZKE/V, ZKE/S, ZKE/S3, ZKE/S4, ZKE/S5, ZKE/Y, ZKE/Y1, ZKE/Y3, ZKE/Y4, ZKE/Y5 all refer to the same product.

Do you supply ZKE in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including ZKE, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

Manufacturer reference: https://www.sunhydraulics.com/model/ZKE

See It Styled On Instagram