RVEA-LAN – Sun Hydraulics Ventable, pilot-operated, balanced piston relief valve
Part number: RVEALAN · RVEA-LAN · RVEA LAN
Ventable, pilot-operated, balanced piston relief valve. Cavity T-2A, capacity 30 gpm (120 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.
RVEA-LAN overview
RVEALAN (RVEA-LAN, RVEA LAN) is a Sun Hydraulics Sun Hydraulics Ventable, pilot-operated, balanced piston relief valve, rated 30 gpm (120 L/min.) and installed in cavity T-2A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.
Ordering codes
Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.
| RVEALAN/AP | Stainless Steel, PassivatedStainless Steel, Passivated |
|---|---|
| RVEALAN/LH | Mild Steel, Zinc-NickelMild Steel, Zinc-Nickel |
| RVEALAN | Standard Material/CoatingStandard Material/Coating |
Specifications
| Cavity | T-2A |
|---|---|
| Series | 2 |
| Capacity | 30 gpm (120 L/min.) |
| Maximum Operating Pressure | 5000 psi (350 bar) |
| Factory Pressure Settings Established at | 4 gpm (15 L/min.) |
| Control Pilot Flow | 10 - 15 in³/min. (0,16 - 0,25 L/min.) |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 3 in³/min.@1000 psi (50 cc/min.@70 bar) |
| Response Time - Typical | 10 ms |
| Adjustment - No. of CW Turns from Min. to Max. setting | 5 |
| Valve Hex Size | 1 1/8 in. (28,6 mm) |
| Valve Installation Torque | 45 - 50 lbf ft (61 - 68 Nm) |
| Adjustment Screw Internal Hex Size | 5/32 in. (4 mm) |
| Locknut Hex Size | 9/16 in. (15 mm) |
| Locknut Torque | 80 - 90 lbf in. (9 - 10 Nm) |
| Model Weight | .70 lb (0,30 kg) |
| Seal kit - Cartridge | Viton: 990202006 |
For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
How to read RVEALAN
Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so RVEALAN, RVEA-LAN, RVEA LAN are the same part.
| Model | RVEA — Sun Hydraulics Ventable, pilot-operated, balanced piston relief valve |
|---|---|
| Control | L — Standard Screw Adjustment |
| Adjustment Range | A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting |
| Seal Material | N — Buna-N |
| Material / coating | Add /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish. |
Control options
- L — Standard Screw Adjustment
- C — Tamper Resistant - Factory Set
- K — Handknob
- O — Handknob with Panel Mount
- W — Hex Wrench Adjustment
- Y — Tri-Grip Handknob
- M — Capped Screw Adjustment with Lockwire Holes
- Q — Capped and Lockwired
Adjustment Range options
- A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting
- W — 150 - 4500 psi (10,5 - 315 bar), 1000 psi (70 bar) Standard Setting
- B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting
- C — 150 - 6000 psi (10,5 - 420 bar), 1000 psi (70 bar) Standard Setting
- D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting
- E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting
- F — 75 - 6000 psi (5 - 420 bar), 1000 psi (70 bar) Standard Setting
- G — 60 - 3000 psi (4 - 210 bar), 1000 psi (70 bar) Standard Setting
- H — 30 - 3000 psi (2 - 210 bar), 1000 psi (70 bar) Standard Setting
- I — 15 - 1500 psi (1 - 105 bar), 1000 psi (70 bar) Standard Setting
- J — 25 - 1500 psi (1,7 - 105 bar), 1000 psi (70 bar) Standard Setting
- K — 75 - 1500 psi (5 - 105 bar), 1000 psi (70 bar) Standard Setting
- L — 15 - 800 psi (1 - 55 bar), 400 psi (28 bar) Standard Setting
- M — 40 - 800 psi (2,8 - 55 bar), 400 psi (28 bar) Standard Setting
- N — 60 - 800 psi (4 - 55 bar), 400 psi (28 bar) Standard Setting
- O — 15 - 400 psi (1 - 28 bar), 200 psi (14 bar) Standard Setting
- P — 40 - 400 psi (2,8 - 28 bar), 200 psi (14 bar) Standard Setting
- Q — 60 - 400 psi (4 - 28 bar), 200 psi (14 bar) Standard Setting
- R — 15 - 200 psi (1 - 14 bar), 100 psi (7 bar) Standard Setting
- S — 25 - 200 psi (1,7 - 14 bar), 100 psi (7 bar) Standard Setting
- T — 40 - 200 psi (2,8 - 14 bar), 100 psi (7 bar) Standard Setting
- U — 60 - 200 psi (4 - 14 bar), 100 psi (7 bar) Standard Setting
- V — 150 - 800 psi (10,5 - 55 bar), 400 psi (28 bar) Standard Setting
- Y — 30 - 4500 psi (2 - 315 bar), 1000 psi (70 bar) Standard Setting
Seal Material options
- N — Buna-N
- V — Viton
- E — EPDM
Material/coating options
- /AP — Stainless Steel, Passivated
- /LH — Mild Steel, Zinc-Nickel
- — Standard Material/Coating
Manifold & standard assemblies
Sun manifolds for cavity T-2A (544)
- 3BC Sun Hydraulics Cushion lock with shuttle Line mount manifoldRVEALAN-3BC — request assembly
- 3BD Sun Hydraulics Cushion lock with shuttle Line mount manifoldRVEALAN-3BD — request assembly
- 3BK Sun Hydraulics Cushion lock with shuttle Line mount manifoldRVEALAN-3BK — request assembly
- 3BL Sun Hydraulics Cushion lock with shuttle Line mount manifoldRVEALAN-3BL — request assembly
- 3BV Sun Hydraulics Cushion lock with shuttle Line mount manifoldRVEALAN-3BV — request assembly
- 3BW Sun Hydraulics Cushion lock with shuttle Line mount manifoldRVEALAN-3BW — request assembly
- 4BC Sun Hydraulics Cushion lock with make up checks Line mount manifoldRVEALAN-4BC — request assembly
- 4BD Sun Hydraulics Cushion lock with make up checks Line mount manifoldRVEALAN-4BD — request assembly
- 4BK Sun Hydraulics Cushion lock with make up checks Line mount manifoldRVEALAN-4BK — request assembly
- 4BL Sun Hydraulics Cushion lock with make up checks Line mount manifoldRVEALAN-4BL — request assembly
- 4BV Sun Hydraulics Cushion lock with make up checks Line mount manifoldRVEALAN-4BV — request assembly
- 4BW Sun Hydraulics Cushion lock with make up checks Line mount manifoldRVEALAN-4BW — request assembly
Technical features
- A remote pilot relief on port 3 (vent) will control the valve below its own setting.
- Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
- Main stage orifice is protected by a 150-micron stainless steel screen.
- Not suitable for use in load holding applications due to spool leakage.
- Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Drawings, symbol & performance curves
Downloads
Datasheet
Technical reference sheets
- 999-901-334 (PDF 344 KB)
- FloatingStyleScrewInCartridge2 (PDF 1 MB)
- TT_US_Cavity-New (PDF 522 KB)
- TT_US_Relief-N (PDF 656 KB)
CAD files
Frequently asked questions
Is RVEALAN the same as RVEA-LAN?
Yes. Sun Hydraulics writes this part number as RVEALAN. It is the model RVEA followed by the configuration code; hyphens, slashes and spaces are only dividers, so RVEALAN, RVEA-LAN, RVEA LAN all refer to the same product.
Do you supply RVEALAN in the UAE, GCC and India?
Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including RVEALAN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.
Can I get the datasheet and CAD files?
Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.
Direct acting or pilot operated - what do I use?
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
Where would I use a kick-down relief?
One graphic example is on a portable grain auger for silos. When the farmer gets caught in the auger the kick-down relief trips and allows him to escape.
What are the tolerances on pressure settings for Sun's pressure control valves?
Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page.
How big is a drop of hydraulic oil?
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Can I use a kick-down relief for my system relief?
Maybe not. We build in a good amount of overlap in the kick-down reliefs to prevent false tripping. This means they are not as fast as our standard pilot-operated reliefs. A direct-acting relief valve set just above the kick-down relief valve would be good insurance.
What parts of the Sun cartridge valve are field serviceable?
Manufacturer reference: https://www.sunhydraulics.com/model/RVEA