FMDFXDN – Sun Hydraulics Electro-proportional 3-way flow control valve, meter in (740 Series), No coil

Part number: FMDFXDN · FMDF-XDN · FMDF XDN

Brand Sun HydraulicsType Flow ControlCapacity 9 gpm (34 L/min.)Cavity T-11A

Electro-proportional 3-way flow control valve, meter in (740 Series). Cavity T-11A, capacity 9 gpm (34 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: FMDF Category: Brand:

FMDF-XDN overview

FMDFXDN (FMDF-XDN, FMDF XDN) is a Sun Hydraulics Sun Hydraulics Electro-proportional 3-way flow control valve, meter in (740 Series), rated 9 gpm (34 L/min.) and installed in cavity T-11A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

FMDFXDN No coilNo coil
FMDFXDN211 DIN 43650-Form A, 115 VACDIN 43650-Form A, 115 VAC
FMDFXDN212 DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC
FMDFXDN212D DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodesDIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes

Specifications

CavityT-11A
Series1
Capacity9 gpm (34 L/min.)
Maximum Operating Pressure5000 psi (350 bar)
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi (30 cc/min.@70 bar)
Manual Override Force Requirement5 lbs/1000 psi @ Port 1 (33 N/100 bar @ Port 1)
Manual Override Stroke.10 in. (2,5 mm)
Solenoid Tube Diameter.63 in. (16 mm)
Valve Hex Size7/8 in. (22,2 mm)
Valve Installation Torque30 - 35 lbf ft (41 - 47 Nm)

Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances. An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.

How to read FMDFXDN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so FMDFXDN, FMDF-XDN, FMDF XDN are the same part.

ModelFMDF — Sun Hydraulics Electro-proportional 3-way flow control valve, meter in (740 Series)
ControlX — No Manual Override
Flow RateD — .1 - 9 gpm (0,4 - 34 L/min.)
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Control options
  • X — No Manual Override
  • D — Twist/Lock (Dual) Manual Override
  • L — Twist/Lock (Detent) Manual Override
  • M — Manual Override
  • T — Twist (Momentary) Manual Override
Flow Rate options
  • A — .1 - 1.6 gpm (0,4 - 6.1 L/min.)
  • B — .1 - 4 gpm (0,4 - 15 L/min.)
  • C — .1 - 6 gpm (0,4 - 23 L/min.)
  • D — .1 - 9 gpm (0,4 - 34 L/min.)
Seal Material options
  • N — Buna-N
  • V — Viton
Coil options
  • — No coil
  • 211 — DIN 43650-Form A, 115 VAC
  • 212 — DIN 43650-Form A, 12 VDC
  • 212D — DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes
  • 212X01 — DIN 43650-Form A, 12 VDC, with XMD-01 driver
  • 212X02 — DIN 43650-Form A, 12 VDC, with XMD-02 driver
  • 214 — DIN 43650-Form A, 14 VDC
  • 214D — DIN 43650-Form A, 14 VDC, with transient voltage suppression (TVS) diodes
  • 214X01 — DIN 43650-Form A, 14 VDC, with XMD-01 driver
  • 214X02 — DIN 43650-Form A, 14 VDC, with XMD-02 driver
  • 223 — DIN 43650-Form A, 230 VAC
  • 224 — DIN 43650-Form A, 24 VDC
  • 224D — DIN 43650-Form A, 24 VDC, with transient voltage suppression (TVS) diodes
  • 224X01 — DIN 43650-Form A, 24 VDC, with XMD-01 driver
  • 224X02 — DIN 43650-Form A, 24 VDC, with XMD-02 driver
  • 228 — DIN 43650-Form A, 28 VDC
  • 228D — DIN 43650-Form A, 28 VDC, with transient voltage suppression (TVS) diodes
  • 228X01 — DIN 43650-Form A, 28 VDC, with XMD-01 driver
  • 228X02 — DIN 43650-Form A, 28 VDC, with XMD-02 driver
  • 612 — AMP Junior Timer, 12 VDC
  • 612D — AMP Junior Timer, 12 VDC, with transient voltage suppression (TVS) diodes
  • 614 — AMP Junior Timer, 14 VDC
  • 614D — AMP Junior Timer, 14 VDC, with transient voltage suppression (TVS) diodes
  • 624 — AMP Junior Timer, 24 VDC
  • 624D — AMP Junior Timer, 24 VDC, with transient voltage suppression (TVS) diodes
  • 628 — AMP Junior Timer, 28 VDC
  • 628D — AMP Junior Timer, 28 VDC, with transient voltage suppression (TVS) diodes
  • 712 — Twin Lead, 12 VDC
  • 712D — Twin Lead, 12 VDC, with transient voltage suppression (TVS) diodes
  • 714 — Twin Lead, 14 VDC
  • 714D — Twin Lead, 14 VDC, with transient voltage suppression (TVS) diodes
  • 724 — Twin Lead, 24 VDC
  • 724D — Twin Lead, 24 VDC, with transient voltage suppression (TVS) diodes
  • 728 — Twin Lead, 28 VDC
  • 728D — Twin Lead, 28 VDC, with transient voltage suppression (TVS) diodes
  • 812 — Metri-Pack, 12 VDC
  • 812D — Metri-Pack, 12 VDC, with transient voltage suppression (TVS) diodes
  • 814 — Metri-Pack, 14 VDC
  • 814D — Metri-Pack, 14 VDC, with transient voltage suppression (TVS) diodes
  • 824 — Metri-Pack, 24 VDC
  • 824D — Metri-Pack, 24 VDC, with transient voltage suppression (TVS) diodes
  • 828 — Metri-Pack, 28 VDC
  • 828D — Metri-Pack, 28 VDC, with transient voltage suppression (TVS) diodes
  • 912 — Deutsch DT04-2P, 12 VDC
  • 912D — Deutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodes
  • 912LX02 — Deutsch DT04-2P, 12 VDC, low power, with XMD-02 driver
  • 912X01 — Deutsch DT04-2P, 12 VDC, with XMD-01 driver
  • 914 — Deutsch DT04-2P, 14 VDC
  • 914D — Deutsch DT04-2P, 14 VDC, with transient voltage suppression (TVS) diodes
  • 914X01 — Deutsch DT04-2P, 14 VDC, with XMD-01 driver
  • 914X02 — Deutsch DT04-2P, 14 VDC, with XMD-02 driver
  • 924 — Deutsch DT04-2P, 24 VDC
  • 924D — Deutsch DT04-2P, 24 VDC, with transient voltage suppression (TVS) diodes
  • 924X01 — Deutsch DT04-2P, 24 VDC, with XMD-01 driver
  • 924X02 — Deutsch DT04-2P, 24 VDC, with XMD-02 driver
  • 928 — Deutsch DT04-2P, 28 VDC
  • 928D — Deutsch DT04-2P, 28 VDC, with transient voltage suppression (TVS) diodes
  • 928X01 — Deutsch DT04-2P, 28 VDC, with XMD-01 driver
  • 928X02 — Deutsch DT04-2P, 28 VDC, with XMD-02 driver
  • JM24BD — Explosion Proof, Metric (M20 X 1.5), 24 VDC, 180 Degree, CSA and ATEX Certification
  • JM24CD — Explosion Proof, Metric (M20 X 1.5), 24 VDC, 90 Degree, CSA and ATEX Certification
  • JN24BD — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 180 Degree, CSA and ATEX Certification
  • JN24CD — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 90 Degree, CSA and ATEX Certification

Manifold & standard assemblies

Sun manifolds for cavity T-11A (583)

View all 583 →

Technical features

  • Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
  • The transition between positions is closed.
  • Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
  • These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
  • The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
  • For optimum performance, an amplifier with current feedback and adjustable dither (100 - 250 Hz) should be used.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Drawings, symbol & performance curves

FMDF-XDN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDF-XDN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDF-XDN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDF-XDN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDF-XDN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDF-XDN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDFXDN Sun Hydraulics Flow Control Valve – 2D outline drawing
2D outline drawing

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is FMDFXDN the same as FMDF-XDN?

Yes. Sun Hydraulics writes this part number as FMDFXDN. It is the model FMDF followed by the configuration code; hyphens, slashes and spaces are only dividers, so FMDFXDN, FMDF-XDN, FMDF XDN all refer to the same product.

Do you supply FMDFXDN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including FMDFXDN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

What is the pressure drop through a flow control?

In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.

How accurate are Sun's flow controls?

We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.

I have a heat problem, will Sun's priority flow control help?

I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.

What happens if I block the control flow (priority) port?

All flow is blocked, hence the term priority. The priority flow has to be satisfied.

What happens if I block the bypass port on a priority flow control?

The valve acts as a 2 port restrictive flow control.

What is the compensating pressure of Sun's flow controls?

The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.

How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

Manufacturer reference: https://www.sunhydraulics.com/model/FMDF

See It Styled On Instagram

    No access token