DFDBXCN211 – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1, DIN 43650-Form A, 115 VAC

Part number: DFDBXCN · DFDB-XCN · DFDB XCN

Brand Sun HydraulicsType 2-wayCapacity 30 gpm (120 L/min.)Cavity T-5A

2-way, 2-stage, solenoid-operated directional poppet valve – flow 2-1. Cavity T-5A, capacity 30 gpm (120 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: DFDB Category: Brand:

DFDB-XCN overview

DFDBXCN (DFDB-XCN, DFDB XCN) is a Sun Hydraulics Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1, rated 30 gpm (120 L/min.) and installed in cavity T-5A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

DFDBXCN No coilNo coil
DFDBXCN211 DIN 43650-Form A, 115 VACDIN 43650-Form A, 115 VAC
DFDBXCN212 DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC
DFDBXCN212N DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodesDIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes

Specifications

CavityT-5A
Series2
Capacity30 gpm (120 L/min.)
Maximum Operating Pressure5000 psi (350 bar)
Maximum Valve Leakage at 110 SUS (24 cSt)10 drops/min.@5000 psi (0,7 cc/min.@350 bar)
Check Cracking Pressure50 psi (3,5 bar)
Response Time - Typical30 ms
Switching Frequency15,000 max. cycles/hr
Solenoid Tube Diameter.75 in. (19 mm)
Valve Hex Size1 1/8 in. (28,6 mm)
Valve Installation Torque45 - 50 lbf ft (61 - 68 Nm)
Model Weight.70 lb (0,30 kg)
Seal kit - CartridgeViton: 990203006

Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances. An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.

How to read DFDBXCN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so DFDBXCN, DFDB-XCN, DFDB XCN are the same part.

ModelDFDB — Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1
ControlX — No Manual Override
Poppet ConfigurationC — Normally Closed
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Control options
  • X — No Manual Override
  • D — Twist/Lock (Dual) Manual Override
  • L — Twist/Lock (Detent) Manual Override
  • M — Manual Override
  • T — Twist (Momentary) Manual Override
Poppet Configuration options
  • C — Normally Closed
  • H — Normally Open
Seal Material options
  • N — Buna-N
  • V — Viton
  • E — EPDM
Coil options
  • — No coil
  • 211 — DIN 43650-Form A, 115 VAC
  • 212 — DIN 43650-Form A, 12 VDC
  • 212N — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes
  • 214 — DIN 43650-Form A, 14 VDC
  • 214N — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes
  • 223 — DIN 43650-Form A, 230 VAC
  • 224 — DIN 43650-Form A, 24 VDC
  • 224N — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes
  • 228 — DIN 43650-Form A, 28 VDC
  • 812 — Metri-Pack, 12 VDC
  • 912 — Deutsch DT04-2P, 12 VDC
  • 912N — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes
  • 914 — Deutsch DT04-2P, 14 VDC
  • 914N — Deutsch DT04-2P, 14 VDC, no transient voltage suppression (TVS) diodes
  • 924 — Deutsch DT04-2P, 24 VDC
  • 924N — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes
  • 928 — Deutsch DT04-2P, 28 VDC
  • HN24AA — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 10 feet twin lead, ATEX Certification Ex mb IIC T3 Gb.
  • HN24AB — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 10 feet twin lead, CSA Certification

Manifold & standard assemblies

Sun manifolds for cavity T-5A (106)

View all 106 →

Technical features

  • The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Valves exhibit extremely low leakage rates; less than 10 drops/min. @ 5000 psi (0,7 cc/min @ 350 bar).
  • This cartridge has several manual override choices, including no manual override. See the CONFIGURATION section. Please note: Manual override functionality is not compatible with weatherized coils.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • The solenoid's unique magnetic design results in a high efficiency solenoid, yielding high spool actuating force per Watt expended, leading to reliable valve shifting.
  • Coils are interchangeable with other Sun Series 1 solenoid products and can be mounted on the tube in either direction.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details. Additional weatherized coils and kits are available for more complete environmental protection.
  • Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Drawings, symbol & performance curves

DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – hydraulic schematic symbol
hydraulic schematic symbol
DFDB-XCN Sun Hydraulics 2-way Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
DFDBXCN Sun Hydraulics 2-way Valve – 2D outline drawing
2D outline drawing

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is DFDBXCN the same as DFDB-XCN?

Yes. Sun Hydraulics writes this part number as DFDBXCN. It is the model DFDB followed by the configuration code; hyphens, slashes and spaces are only dividers, so DFDBXCN, DFDB-XCN, DFDB XCN all refer to the same product.

Do you supply DFDBXCN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including DFDBXCN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct acting or pilot operated - what do I use?

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

Manufacturer reference: https://www.sunhydraulics.com/model/DFDB

See It Styled On Instagram

    No access token

Main Menu