Product Price Quantity Total  
CBDB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBLHN-ZEN/S3

ZEN Sun Hydraulics Ninety degree Line mount manifold drawing ZEN – Sun Hydraulics Ninety degree Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDBLHN-ZEN/S3

DKJP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DKJP-LAN – Sun Hydraulics Normally closed, balanced poppet, logic element - pressure adjustable - Standard Material/Coating
Assembly:

DKJPLAN-Q4M/S4

Q4M Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4M – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

DKJPLAN-Q4M/S4

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-WRC

WRC Sun Hydraulics Direct mount, through port 2 Line mount manifold drawing WRC – Sun Hydraulics Direct mount, through port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDXXN-WRC

DFEI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFEIXCN-CDO/W5

CDO Sun Hydraulics ISO 08: P to T Sandwich manifold drawing CDO – Sun Hydraulics ISO 08: P to T Sandwich manifold - /W5 – 65-45-12 Ductile Iron, Metric, Viton, Electroless Nickel
Assembly:

DFEIXCN-CDO/W5

CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-BBA/W

BBA Sun Hydraulics ISO 05: On A, port 3 to B Sandwich manifold drawing BBA – Sun Hydraulics ISO 05: On A, port 3 to B Sandwich manifold - /W – 65-45-12 Ductile Iron, Metric, Viton, Dewatering Oil
Assembly:

CBDDLJN-BBA/W

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-YQS

YQS Sun Hydraulics Four port directional circuit using logic valves, NPT pilot ports Line mount manifold drawing YQS – Sun Hydraulics Four port directional circuit using logic valves, NPT pilot ports Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGALHN-YQS

DOJD-EHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-19A DOJD-EHN – Sun Hydraulics Normally open, balanced poppet, logic element - vent-to-close - N – Buna-N
Assembly:

DOJDEHN-K2D

K2D Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2D – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DOJDEHN-K2D

CBIY-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIY-LHN – Sun Hydraulics 2:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBIYLHN-KFR

KFR Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing KFR – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBIYLHN-KFR

NQEB-XAN Sun Hydraulics Air bleed and start-up Valve – installation dimensions drawing, cavity T-3A NQEB-XAN – Sun Hydraulics Air bleed and start-up valve - Standard Material/Coating
Assembly:

NQEBXAN-CKB/W3

CKB Sun Hydraulics ISO 07: B to T Sandwich manifold drawing CKB – Sun Hydraulics ISO 07: B to T Sandwich manifold - /W3 – 65-45-12 Ductile Iron, Metric, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

NQEBXAN-CKB/W3

CWEA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-22A CWEA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWEALHN-NAU/S

NAU Sun Hydraulics Ninety degree Line mount manifold drawing NAU – Sun Hydraulics Ninety degree Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CWEALHN-NAU/S

CABN-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABN-LHN – Sun Hydraulics 7:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CABNLHN-C3H/S4

C3H Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing C3H – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CABNLHN-C3H/S4

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-U9E/S

U9E Sun Hydraulics Danfoss OMV: Cross pilot with shuttle Motor mount manifold drawing U9E – Sun Hydraulics Danfoss OMV: Cross pilot with shuttle Motor mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CBDBXNN-U9E/S

DKJP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DKJP-LAN – Sun Hydraulics Normally closed, balanced poppet, logic element - pressure adjustable - Standard Material/Coating
Assembly:

DKJPLAN-Q4R/S3

Q4R Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4R – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DKJPLAN-Q4R/S3

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-EFB/S3

EFB Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing EFB – Sun Hydraulics Ninety degree with gauge port Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CABKLHN-EFB/S3

DKJR-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DKJR-XHN – Sun Hydraulics Normally closed, balanced poppet, logic element - vent-to-open - V – Viton
Assembly:

DKJRXHV-Q4M

Q4M Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4M – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DKJRXHV-Q4M

CVGV-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-23A CVGV-XCN – Sun Hydraulics Vented pilot-to-open check valve - Standard Material/Coating
Assembly:

CVGVXCN-ZEV

ZEV Sun Hydraulics Direct mount Line mount manifold drawing ZEV – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CVGVXCN-ZEV

Back To Shop

Cart totals

Subtotal
Total

Main Menu