Product Price Quantity Total  
DFFA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - No coil
Assembly:

DFFAXCN-U4E/T3

U4E Sun Hydraulics Sandwich mount through port Line mount manifold drawing U4E – Sun Hydraulics Sandwich mount through port Line mount manifold - /T3 – 65-45-12 Ductile Iron, Metric, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DFFAXCN-U4E/T3

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-E9C/Y5

E9C Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold drawing E9C – Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CACKLHN-E9C/Y5

CBIH-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIH-LJN – Sun Hydraulics 10:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBIHLJN-KER/S3

KER Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing KER – Sun Hydraulics Ninety degree with gauge port Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBIHLJN-KER/S3

CAIG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAIGLGN-KF6/T5

KF6 Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing KF6 – Sun Hydraulics Ninety degree with gauge port Line mount manifold - /T5 – 65-45-12 Ductile Iron, Metric, Buna-N, Electroless Nickel
Assembly:

CAIGLGN-KF6/T5

DKFS-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-22A DKFS-XHN – Sun Hydraulics Normally closed, balanced poppet, logic element - pilot-to-open - Standard Material/Coating
Assembly:

DKFSXHN-N4B/Y5

N4B Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4B – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

DKFSXHN-N4B/Y5

XZOB-XXN Sun Hydraulics Cavity Plug Valve – hydraulic schematic symbol XZOB-XXN – Sun Hydraulics Port 1 to 2 open, port 3 blocked cavity plug - Standard Material/Coating
Assembly:

XZOBXXN-J6B

J6B Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing J6B – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

XZOBXXN-J6B

DNDU-XCN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity T-31A DNDU-XCN – Sun Hydraulics 4-way, 2-position, solenoid-operated directional blocking valve (740 Series) - No coil
Assembly:

DNDUXCN-W2A/S3

W2A Sun Hydraulics Ninety degree Line mount manifold drawing W2A – Sun Hydraulics Ninety degree Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DNDUXCN-W2A/S3

RDDA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RDDA-LAN – Sun Hydraulics Direct-acting relief valve - /LH – Mild Steel, Zinc-Nickel
Assembly:

RDDALAN/LH-CBG

CBG Sun Hydraulics ISO 05: B to T Sandwich manifold drawing CBG – Sun Hydraulics ISO 05: B to T Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RDDALAN/LH-CBG

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-BBP/S5

BBP Sun Hydraulics ISO 05: On P, port 3 to T Sandwich manifold drawing BBP – Sun Hydraulics ISO 05: On P, port 3 to T Sandwich manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CBDBXNN-BBP/S5

CXGD-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-16A CXGD-XCN – Sun Hydraulics Free flow side to nose check valve - /LH – Mild Steel, Zinc-Nickel
Assembly:

CXGDXCN/LH-CDO

CDO Sun Hydraulics ISO 08: P to T Sandwich manifold drawing CDO – Sun Hydraulics ISO 08: P to T Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXGDXCN/LH-CDO

DNDC-XCN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity T-31A DNDC-XCN – Sun Hydraulics 4-way, 3-position, solenoid-operated directional spool valve - No coil
Assembly:

DNDCXCN-W2E

W2E Sun Hydraulics Ninety degree Line mount manifold drawing W2E – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DNDCXCN-W2E

DFBG-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DFBG-XCN – Sun Hydraulics FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1 - No coil
Assembly:

DFBGXCN-AGU

AGU Sun Hydraulics Ninety degree, ports 1 & 2 through Line mount manifold drawing AGU – Sun Hydraulics Ninety degree, ports 1 & 2 through Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFBGXCN-AGU

CWIL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-24A CWIL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWILLGN-XL8/S3

XL8 Sun Hydraulics Cross pilot with common port 4s Line mount manifold drawing XL8 – Sun Hydraulics Cross pilot with common port 4s Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CWILLGN-XL8/S3

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-E5U/Y

E5U Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold drawing E5U – Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CACALHN-E5U/Y

Back To Shop

Cart totals

Subtotal
Total

Main Menu