Product Price Quantity Total  
RPGC8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RPGC8-WN – Sun Hydraulics Pilot-operated, balanced piston relief main stage with integral T-8A control cavity - N – Buna-N
Assembly:

RPGC8WN-CJB/Y3

CJB Sun Hydraulics ISO 05 - X&Y: B to T Sandwich manifold drawing CJB – Sun Hydraulics ISO 05 - X&Y: B to T Sandwich manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

RPGC8WN-CJB/Y3

DPBB-LAN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-11A DPBB-LAN – Sun Hydraulics 2-way, pilot-operated, directional valve with internal drain to port 3 - normally closed - Standard Material/Coating
Assembly:

DPBBLAN-A2K

A2K Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2K – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DPBBLAN-A2K

PRHB-LAN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-17A PRHB-LAN – Sun Hydraulics Direct-acting, pressure reducing/relieving valve - Standard Material/Coating
Assembly:

PRHBLAN-BK4

BK4 Sun Hydraulics ISO 07: Sequence into A with reverse flow check Sandwich manifold drawing BK4 – Sun Hydraulics ISO 07: Sequence into A with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PRHBLAN-BK4

LOJOZ-DN Sun Hydraulics Position Indication Valve – installation dimensions drawing, cavity T-19A LOJOZ-DN – Sun Hydraulics Pilot-to-close, spring-biased open, unbalanced poppet logic element with position switch - V – Viton
Assembly:

LOJOZDV-K2L

K2L Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2L – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LOJOZDV-K2L

CWEL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-22A CWEL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWELLGN-XRC/S3

XRC Sun Hydraulics Cross pilot with independent port 4s Line mount manifold drawing XRC – Sun Hydraulics Cross pilot with independent port 4s Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CWELLGN-XRC/S3

CAGL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGLLGN-XYM/S5

XYM Sun Hydraulics Staffa 4", 5 piston: Cross pilot Motor mount manifold drawing XYM – Sun Hydraulics Staffa 4", 5 piston: Cross pilot Motor mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CAGLLGN-XYM/S5

RPES-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPES-LAN – Sun Hydraulics Pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPESLAN-FAW/S3

FAW Sun Hydraulics Ninety degree Line mount manifold drawing FAW – Sun Hydraulics Ninety degree Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RPESLAN-FAW/S3

CAEL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAELLGN-WPC

WPC Sun Hydraulics All gasket ports Gasket mount manifold drawing WPC – Sun Hydraulics All gasket ports Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAELLGN-WPC

NFFD-LIN Sun Hydraulics Needle Valve – installation dimensions drawing, cavity T-18A NFFD-LIN – Sun Hydraulics Fully adjustable needle valve - Standard Material/Coating
Assembly:

NFFDLIN-LAE

LAE Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing LAE – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

NFFDLIN-LAE

DFBE-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DFBE-XCN – Sun Hydraulics FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1, 3000 psi (210 bar) - No coil
Assembly:

DFBEXCN-ABS

ABS Sun Hydraulics ISO 03 - 30mm: Out of T Sandwich manifold drawing ABS – Sun Hydraulics ISO 03 - 30mm: Out of T Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFBEXCN-ABS

MWDP-DHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-21A MWDP-DHN – Sun Hydraulics Vented LoadMatch™ counterbalance valve - Standard Material/Coating
Assembly:

MWDPDHN-MAB

MAB Sun Hydraulics Ninety degree Line mount manifold drawing MAB – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

MWDPDHN-MAB

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-XVS

XVS Sun Hydraulics 4 signal load sense shuttle body Line mount manifold drawing XVS – Sun Hydraulics 4 signal load sense shuttle body Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACKLHN-XVS

MBGG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A MBGG-LJN – Sun Hydraulics 4.5:1 pilot ratio, load reactive, load control valve - Standard Material/Coating
Assembly:

MBGGLJN-BK9

BK9 Sun Hydraulics ISO 07: Reducer on A and B with reverse flow check Sandwich manifold drawing BK9 – Sun Hydraulics ISO 07: Reducer on A and B with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

MBGGLJN-BK9

RBAA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBAA-LAN – Sun Hydraulics Direct-acting relief valve - pilot capacity - Standard Material/Coating
Assembly:

RBAALAN-VMK/S3

VMK Sun Hydraulics 2 Station, Parallel circuit with relief cavity Bar manifold manifold drawing VMK – Sun Hydraulics 2 Station, Parallel circuit with relief cavity Bar manifold manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RBAALAN-VMK/S3

DODP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-21A DODP-LAN – Sun Hydraulics Normally open, balanced poppet, logic element - pressure adjustable - N – Buna-N
Assembly:

DODPLAN-WDB/S3

WDB Sun Hydraulics Direct mount, cross pilot Gasket mount manifold drawing WDB – Sun Hydraulics Direct mount, cross pilot Gasket mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DODPLAN-WDB/S3

RSDS8-WN Sun Hydraulics Sequence Valve – installation dimensions drawing, cavity T-11A RSDS8-WN – Sun Hydraulics Pilot-operated, balanced poppet sequence main stage with integral T-8A control cavity - N – Buna-N
Assembly:

RSDS8WN-A2U

A2U Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2U – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RSDS8WN-A2U

LODC-XDN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-11A LODC-XDN – Sun Hydraulics Pilot-to-close, spring-biased closed, unbalanced poppet logic element - Standard Material/Coating
Assembly:

LODCXDN-A2U

A2U Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2U – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LODCXDN-A2U

FXDA-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-5A FXDA-XAN – Sun Hydraulics Fixed-orifice, pressure compensated flow control valve - Standard Material/Coating
Assembly:

FXDAXAN-DAA

DAA Sun Hydraulics Ninety degree Line mount manifold drawing DAA – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FXDAXAN-DAA

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-3BL

3BL Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing 3BL – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-3BL

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-ZML/S4

ZML Sun Hydraulics Sandwich mount through port Line mount manifold drawing ZML – Sun Hydraulics Sandwich mount through port Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CACKLHN-ZML/S4

CBAA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAA-LHN – Sun Hydraulics 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAALHN-A7J

A7J Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A7J – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAALHN-A7J

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-BLD

BLD Sun Hydraulics Ninety degree with high capacity port 3 and gauge port Line mount manifold drawing BLD – Sun Hydraulics Ninety degree with high capacity port 3 and gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCXNN-BLD

DOFS-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-22A DOFS-XHN – Sun Hydraulics Normally open, balanced poppet, logic element - pilot-to-close - Standard Material/Coating
Assembly:

DOFSXHN-N4A

N4A Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4A – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DOFSXHN-N4A

DOJP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DOJP-LAN – Sun Hydraulics Normally open, balanced poppet, logic element - pressure adjustable - Standard Material/Coating
Assembly:

DOJPLAN-Q4R

Q4R Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4R – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DOJPLAN-Q4R

PVJA8-WN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-24A PVJA8-WN – Sun Hydraulics Pilot-operated, pressure reducing/relieving main stage with integral T-8A control cavity and drain to port 4 - N – Buna-N
Assembly:

PVJA8WN-Q4L

Q4L Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4L – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PVJA8WN-Q4L

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-B7C

B7C Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing B7C – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-B7C

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-A8B

A8B Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A8B – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-A8B

DFFA8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFA8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2 - Standard Material/Coating
Assembly:

DFFA8DN-LNN

LNN Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing LNN – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFFA8DN-LNN

DFDI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-5A DFDI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFDIXCN-VFG/S3

VFG Sun Hydraulics Inline Line mount manifold drawing VFG – Sun Hydraulics Inline Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DFDIXCN-VFG/S3

LRHA-XHN Sun Hydraulics Modulating Spool Valve – installation dimensions drawing, cavity T-17A LRHA-XHN – Sun Hydraulics Normally closed, modulating element with pilot source from port 1 - Standard Material/Coating
Assembly:

LRHAXHN-BK7

BK7 Sun Hydraulics ISO 07: Sequence out of B with reverse flow check Sandwich manifold drawing BK7 – Sun Hydraulics ISO 07: Sequence out of B with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LRHAXHN-BK7

CBAB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAB-LHN – Sun Hydraulics 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABLHN-C3H

C3H Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing C3H – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABLHN-C3H

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-C3A

C3A Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing C3A – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACKLHN-C3A

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-EET

EET Sun Hydraulics Port 3 connected to port 1 Line mount manifold drawing EET – Sun Hydraulics Port 3 connected to port 1 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-EET

RPID-BBN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-16A RPID-BBN – Sun Hydraulics Air-controlled, pilot-operated, balanced piston relief valve - N – Buna-N
Assembly:

RPIDBBN-CDW

CDW Sun Hydraulics ISO 08: A to B and B to A Sandwich manifold drawing CDW – Sun Hydraulics ISO 08: A to B and B to A Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPIDBBN-CDW

DRBM-LAN Sun Hydraulics 2-way Valve – hydraulic schematic symbol DRBM-LAN – Sun Hydraulics 2-way, direct-acting, directional valve with drain to port 4 - normally open - Standard Material/Coating
Assembly:

DRBMLAN-M4C

M4C Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4C – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DRBMLAN-M4C

CBEL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBEL-LJN – Sun Hydraulics 2.3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBELLJN-3BK

3BK Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing 3BK – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBELLJN-3BK

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-BDW

BDW Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing BDW – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDAXNN-BDW

DRBO-LAN Sun Hydraulics 3-way Valve – hydraulic schematic symbol DRBO-LAN – Sun Hydraulics 3-way, direct-acting, directional valve with drain to port 4 (1 blocked, 2 to 3 open) - Standard Material/Coating
Assembly:

DRBOLAN-M4I

M4I Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4I – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DRBOLAN-M4I

PVDA-LAN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-21A PVDA-LAN – Sun Hydraulics Pilot-operated, pressure reducing/relieving valve with drain to port 4 - Standard Material/Coating
Assembly:

PVDALAN-M4T

M4T Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4T – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PVDALAN-M4T

MBGG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A MBGG-LJN – Sun Hydraulics 4.5:1 pilot ratio, load reactive, load control valve - Standard Material/Coating
Assembly:

MBGGLJN-BK6

BK6 Sun Hydraulics ISO 07: Sequence out of A with reverse flow check Sandwich manifold drawing BK6 – Sun Hydraulics ISO 07: Sequence out of A with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

MBGGLJN-BK6

FKDB-XCN Sun Hydraulics Throttle Valve – installation dimensions drawing, cavity T-22A FKDB-XCN – Sun Hydraulics 2-way, pilot-shifted, proportional throttle with bleed down - V – Viton
Assembly:

FKDBXCV-N4B

N4B Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4B – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FKDBXCV-N4B

RDDA3-AN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RDDA3-AN – Sun Hydraulics Non-adjustable direct-acting relief valve - Standard Material/Coating
Assembly:

RDDA3AN-FAW

FAW Sun Hydraulics Ninety degree Line mount manifold drawing FAW – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RDDA3AN-FAW

CBFA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFALHN-BKA/S3

BKA Sun Hydraulics ISO 07: On A, port 3 to B Sandwich manifold drawing BKA – Sun Hydraulics ISO 07: On A, port 3 to B Sandwich manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBFALHN-BKA/S3

DMDM-LAN Sun Hydraulics 3-way Valve – installation dimensions drawing, cavity T-11A DMDM-LAN – Sun Hydraulics 3-way, manually operated, directional spool valve - N – Buna-N
Assembly:

DMDMLAN-A2U

A2U Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2U – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DMDMLAN-A2U

DFFI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFFIXCN-YLS/S5

YLS Sun Hydraulics Cross port with gauge ports Line mount manifold drawing YLS – Sun Hydraulics Cross port with gauge ports Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

DFFIXCN-YLS/S5

LRHC-XHN Sun Hydraulics Modulating Spool Valve – installation dimensions drawing, cavity T-17A LRHC-XHN – Sun Hydraulics Normally closed, modulating element - Standard Material/Coating
Assembly:

LRHCXHN-BK8

BK8 Sun Hydraulics ISO 07: Cushion lock Sandwich manifold drawing BK8 – Sun Hydraulics ISO 07: Cushion lock Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LRHCXHN-BK8

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-3BD

3BD Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing 3BD – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-3BD

Back To Shop

Cart totals

Subtotal
Total

Main Menu