Product Price Quantity Total  
CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-BND/Y4

BND Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing BND – Sun Hydraulics Cushion lock with shuttle Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CAEGLGN-BND/Y4

CAEL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAELLGN-BGB/S3

BGB Sun Hydraulics Ninety degree with shuttle Line mount manifold drawing BGB – Sun Hydraulics Ninety degree with shuttle Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CAELLGN-BGB/S3

CNDC-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-13A CNDC-XCN – Sun Hydraulics Free flow nose to side check valve with bypass orifice - Standard Material/Coating
Assembly:

CNDCXCN-A6A/S3

A6A Sun Hydraulics Common port 1, accepts standard and weatherized coils Line mount manifold drawing A6A – Sun Hydraulics Common port 1, accepts standard and weatherized coils Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CNDCXCN-A6A/S3

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-ZJH/Y

ZJH Sun Hydraulics Direct mount Line mount manifold drawing ZJH – Sun Hydraulics Direct mount Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CAGALHN-ZJH/Y

DTBF-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DTBF-XCN – Sun Hydraulics FLeX Series 2-way, direct-acting, solenoid-operated directional blocking poppet valve - No coil
Assembly:

DTBFXCN-AGH

AGH Sun Hydraulics Ninety degree, ports 1 & 2 through Line mount manifold drawing AGH – Sun Hydraulics Ninety degree, ports 1 & 2 through Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DTBFXCN-AGH

CBGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGA-LHN – Sun Hydraulics 3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGALHN-H7E/Y3

H7E Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing H7E – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBGALHN-H7E/Y3

CAEA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEALHN-3BV/Y4

3BV Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing 3BV – Sun Hydraulics Cushion lock with shuttle Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CAEALHN-3BV/Y4

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-E7V/Y3

E7V Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing E7V – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CABKLHN-E7V/Y3

DTCAZ-CN224 Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-13A DTCAZ-CN224 – Sun Hydraulics 2-way, direct-acting, solenoid-operated directional blocking poppet valve with overlap and position switch - 224 – DIN 43650-Form A, 24 VDC
Assembly:

DTCAZCN224-A3K

A3K Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing A3K – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DTCAZCN224-A3K

CAIK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAIKLHN-K25/T

K25 Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing K25 – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /T – 65-45-12 Ductile Iron, Metric, Buna-N, Dewatering Oil
Assembly:

CAIKLHN-K25/T

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-VWZ/T5

VWZ Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross pilot with shuttle Motor mount manifold drawing VWZ – Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross pilot with shuttle Motor mount manifold - /T5 – 65-45-12 Ductile Iron, Metric, Buna-N, Electroless Nickel
Assembly:

CAEGLGN-VWZ/T5

DOHR-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-23A DOHR-XHN – Sun Hydraulics Normally open, balanced poppet, logic element - vent-to-close - N – Buna-N
Assembly:

DOHRXHN-VAE/S4

VAE Sun Hydraulics Cross pilot with independent port 4s Line mount manifold drawing VAE – Sun Hydraulics Cross pilot with independent port 4s Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

DOHRXHN-VAE/S4

DTBF-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DTBF-XCN – Sun Hydraulics FLeX Series 2-way, direct-acting, solenoid-operated directional blocking poppet valve - No coil
Assembly:

DTBFXCN-AAI/S4

AAI Sun Hydraulics Ninety degree Line mount manifold drawing AAI – Sun Hydraulics Ninety degree Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

DTBFXCN-AAI/S4

DFFA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - No coil
Assembly:

DFFAXCN-U4E/Y1

U4E Sun Hydraulics Sandwich mount through port Line mount manifold drawing U4E – Sun Hydraulics Sandwich mount through port Line mount manifold - /Y1 – 65-45-12 Ductile Iron, Viton, Clear Zinc Nickel with Top Sealer
Assembly:

DFFAXCN-U4E/Y1

FCDB-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-5A FCDB-XAN – Sun Hydraulics Fixed-orifice pressure compensated flow control valve with reverse flow check - Standard Material/Coating
Assembly:

FCDBXAN-WZA/Y5

WZA Sun Hydraulics Danfoss OMP/OMR: Meter in A and B Motor mount manifold drawing WZA – Sun Hydraulics Danfoss OMP/OMR: Meter in A and B Motor mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

FCDBXAN-WZA/Y5

Back To Shop

Cart totals

Subtotal
Total

Main Menu