Product Price Quantity Total  
CABN-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABN-LHN – Sun Hydraulics 7:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CABNLHN-EMC/S3

EMC Sun Hydraulics Cushion lock Line mount manifold drawing EMC – Sun Hydraulics Cushion lock Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CABNLHN-EMC/S3

NQEB-XAN Sun Hydraulics Air bleed and start-up Valve – installation dimensions drawing, cavity T-3A NQEB-XAN – Sun Hydraulics Air bleed and start-up valve - Standard Material/Coating
Assembly:

NQEBXAN-CEE/S3

CEE Sun Hydraulics Through port with gauge port Line mount manifold drawing CEE – Sun Hydraulics Through port with gauge port Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

NQEBXAN-CEE/S3

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-BDU/S

BDU Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing BDU – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CBDCXNN-BDU/S

CXID-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-18A CXID-XCN – Sun Hydraulics Free flow side to nose check valve - Standard Material/Coating
Assembly:

CXIDXCN-LEM

LEM Sun Hydraulics Through port with gauge port Line mount manifold drawing LEM – Sun Hydraulics Through port with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXIDXCN-LEM

CBAB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAB-LHN – Sun Hydraulics 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABLHN-C3A/S3

C3A Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing C3A – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBABLHN-C3A/S3

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-EDV/S3

EDV Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing EDV – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CACALHN-EDV/S3

CBFD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFDLJN-WTK/S3

WTK Sun Hydraulics Through port 2 with high capacity port 3 and gauge port Line mount manifold drawing WTK – Sun Hydraulics Through port 2 with high capacity port 3 and gauge port Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBFDLJN-WTK/S3

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-EIU/S

EIU Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold drawing EIU – Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CACKLHN-EIU/S

CBDB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBLHN-B2K/S

B2K Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing B2K – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CBDBLHN-B2K/S

CAGL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGLLGN-WPD/Y3

WPD Sun Hydraulics Direct mount, cross pilot Line mount manifold drawing WPD – Sun Hydraulics Direct mount, cross pilot Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CAGLLGN-WPD/Y3

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-BVD/S4

BVD Sun Hydraulics Inline Line mount manifold drawing BVD – Sun Hydraulics Inline Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CBDALHN-BVD/S4

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-B7C/S3

B7C Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing B7C – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDCXNN-B7C/S3

XPOC-NXN Sun Hydraulics Converter Valve – installation dimensions drawing, cavity T-23A XPOC-NXN – Sun Hydraulics T-23A cavity to T-21A cavity or T-22A cavity converter - Standard Material/Coating
Assembly:

XPOCNXN-P4M

P4M Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing P4M – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

XPOCNXN-P4M

DKJP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DKJP-LAN – Sun Hydraulics Normally closed, balanced poppet, logic element - pressure adjustable - Standard Material/Coating
Assembly:

DKJPLAN-WGT

WGT Sun Hydraulics Direct mount Line mount manifold drawing WGT – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DKJPLAN-WGT

Back To Shop

Cart totals

Subtotal
Total

Main Menu