Product Price Quantity Total  
CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-C4T

C4T Sun Hydraulics Ninety degree with gauge port, accepts standard and weatherized coils Line mount manifold drawing C4T – Sun Hydraulics Ninety degree with gauge port, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACKLHN-C4T

CAGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGGLGN-HMF

HMF Sun Hydraulics Cushion lock Line mount manifold drawing HMF – Sun Hydraulics Cushion lock Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGGLGN-HMF

DFEB-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEB-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 - 211 – DIN 43650-Form A, 115 VAC
Assembly:

DFEBXCN211-IA4

IA4 Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing IA4 – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFEBXCN211-IA4

DOHP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-23A DOHP-LAN – Sun Hydraulics Normally open, balanced poppet, logic element - pressure adjustable - Standard Material/Coating
Assembly:

DOHPLAN-PCX

PCX Sun Hydraulics Ninety degree Line mount manifold drawing PCX – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DOHPLAN-PCX

CVCV-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-21A CVCV-XCN – Sun Hydraulics Vented pilot-to-open check valve - Standard Material/Coating
Assembly:

CVCVXCN-MAC/S

MAC Sun Hydraulics Ninety degree Line mount manifold drawing MAC – Sun Hydraulics Ninety degree Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CVCVXCN-MAC/S

RPET-LWN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPET-LWN – Sun Hydraulics Anti-Shock, pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPETLWN-WVG/S4

WVG Sun Hydraulics Danfoss OMS: B to A Motor mount manifold drawing WVG – Sun Hydraulics Danfoss OMS: B to A Motor mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

RPETLWN-WVG/S4

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-U7B

U7B Sun Hydraulics Throttle, low capacity with bypass Line mount manifold drawing U7B – Sun Hydraulics Throttle, low capacity with bypass Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-U7B

CWCH-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-21A CWCH-LGN – Sun Hydraulics 10:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWCHLGN-XFC

XFC Sun Hydraulics Cross pilot with independent port 4s Line mount manifold drawing XFC – Sun Hydraulics Cross pilot with independent port 4s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CWCHLGN-XFC

CABG-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABG-LHN – Sun Hydraulics 4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CABGLHN-EFJ

EFJ Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing EFJ – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABGLHN-EFJ

CACL-LFN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACL-LFN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACLLFN-EPC/Y4

EPC Sun Hydraulics Cushion lock with make up checks Line mount manifold drawing EPC – Sun Hydraulics Cushion lock with make up checks Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CACLLFN-EPC/Y4

RPGC-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RPGC-LAN – Sun Hydraulics Pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPGCLAN-ZKA/S4

ZKA Sun Hydraulics Flange mount through port Line mount manifold drawing ZKA – Sun Hydraulics Flange mount through port Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

RPGCLAN-ZKA/S4

CSAC-BXN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-13A CSAC-BXN – Sun Hydraulics Single ball shuttle valve with signal at port 2 - Standard Material/Coating
Assembly:

CSACBXN-Z5W

Z5W Sun Hydraulics Common port 2 Line mount manifold drawing Z5W – Sun Hydraulics Common port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CSACBXN-Z5W

CABG-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABG-LHN – Sun Hydraulics 4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CABGLHN-VGY

VGY Sun Hydraulics Ninety degree Line mount manifold drawing VGY – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABGLHN-VGY

CDAC-BBN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-13A CDAC-BBN – Sun Hydraulics Back-to-back check/shuttle valve with signal at port 2 - N – Buna-N
Assembly:

CDACBBN-Z5W

Z5W Sun Hydraulics Common port 2 Line mount manifold drawing Z5W – Sun Hydraulics Common port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CDACBBN-Z5W

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-BGA

BGA Sun Hydraulics Ninety degree with shuttle Line mount manifold drawing BGA – Sun Hydraulics Ninety degree with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCXNN-BGA

DACC-MCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-13A DACC-MCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - No coil
Assembly:

DACCMCN-GCT

GCT Sun Hydraulics Inline Line mount manifold drawing GCT – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DACCMCN-GCT

CAIA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAIALHN-K68

K68 Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing K68 – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAIALHN-K68

RBAA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBAA-LAN – Sun Hydraulics Direct-acting relief valve - pilot capacity - Standard Material/Coating
Assembly:

RBAALAN-CAA/S

CAA Sun Hydraulics Ninety degree Line mount manifold drawing CAA – Sun Hydraulics Ninety degree Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

RBAALAN-CAA/S

CAGL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGLLGN-ZEK

ZEK Sun Hydraulics Ninety degree Line mount manifold drawing ZEK – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGLLGN-ZEK

DSCS-XGN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-31A DSCS-XGN – Sun Hydraulics High side, 3-position, shuttle valve - N – Buna-N
Assembly:

DSCSXGN-C8I

C8I Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing C8I – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DSCSXGN-C8I

CSAW-BXN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-162A CSAW-BXN – Sun Hydraulics Single ball shuttle valve with signal external - Standard Material/Coating
Assembly:

CSAWBXN-ACB

ACB Sun Hydraulics Inline Line mount manifold drawing ACB – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CSAWBXN-ACB

DRBMX-FN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-21A DRBMX-FN – Sun Hydraulics 2-way, direct-acting, fixed setting, directional valve with drain to port 4 - normally open - N – Buna-N
Assembly:

DRBMXFN-M4K

M4K Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4K – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DRBMXFN-M4K

CECA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CECA-LHN – Sun Hydraulics 3:1 pilot ratio, standard capacity, LoadAdaptive™ counterbalance valve - Standard Material/Coating
Assembly:

CECALHN-A2K

A2K Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2K – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CECALHN-A2K

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-XVM/S3

XVM Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold drawing XVM – Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CACGLGN-XVM/S3

RBFA-LWN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBFA-LWN – Sun Hydraulics Bi-directional direct-acting relief valve - N – Buna-N
Assembly:

RBFALWN-VML/Y5

VML Sun Hydraulics 3 Station, Parallel circuit with relief cavity Bar manifold manifold drawing VML – Sun Hydraulics 3 Station, Parallel circuit with relief cavity Bar manifold manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

RBFALWN-VML/Y5

CBAA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAA-LHN – Sun Hydraulics 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAALHN-E2I

E2I Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing E2I – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAALHN-E2I

CAIG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAIGLGN-ZLU

ZLU Sun Hydraulics Inline Line mount manifold drawing ZLU – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAIGLGN-ZLU

RPEN-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEN-LAN – Sun Hydraulics Electro-proportional relief valve - high pressure setting with no command (740 Series) - No coil
Assembly:

RPENLAN-FMU

FMU Sun Hydraulics Cross port with make up checks Line mount manifold drawing FMU – Sun Hydraulics Cross port with make up checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPENLAN-FMU

RDFA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RDFA-LAN – Sun Hydraulics Direct-acting relief valve - Standard Material/Coating
Assembly:

RDFALAN-ZKA/S4

ZKA Sun Hydraulics Flange mount through port Line mount manifold drawing ZKA – Sun Hydraulics Flange mount through port Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

RDFALAN-ZKA/S4

DFDA8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-5A DFDA8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2 - Standard Material/Coating
Assembly:

DFDA8DN-UAZ/S4

UAZ Sun Hydraulics All gasket ports Gasket mount manifold drawing UAZ – Sun Hydraulics All gasket ports Gasket mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

DFDA8DN-UAZ/S4

CABG-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABG-LHN – Sun Hydraulics 4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CABGLHN-C4A

C4A Sun Hydraulics Ninety degree with gauge port, accepts standard and weatherized coils Line mount manifold drawing C4A – Sun Hydraulics Ninety degree with gauge port, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABGLHN-C4A

RPES8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPES8-WN – Sun Hydraulics Pilot-operated, balanced poppet relief main stage with integral T-8A control cavity - Standard Material/Coating
Assembly:

RPES8WN-ZCQ

ZCQ Sun Hydraulics Flange mount through port Line mount manifold drawing ZCQ – Sun Hydraulics Flange mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPES8WN-ZCQ

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-W7X

W7X Sun Hydraulics Ninety degree, panel mount Line mount manifold drawing W7X – Sun Hydraulics Ninety degree, panel mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-W7X

RSHS-LAN Sun Hydraulics Sequence Valve – installation dimensions drawing, cavity T-17A RSHS-LAN – Sun Hydraulics Pilot-operated, balanced poppet sequence valve - Standard Material/Coating
Assembly:

RSHSLAN-BK5

BK5 Sun Hydraulics ISO 07: Sequence into B with reverse flow check Sandwich manifold drawing BK5 – Sun Hydraulics ISO 07: Sequence into B with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RSHSLAN-BK5

FQGA-XAN Sun Hydraulics Flow fuse Valve – installation dimensions drawing, cavity T-16A FQGA-XAN – Sun Hydraulics Fixed-orifice, flow fuse valve - Standard Material/Coating
Assembly:

FQGAXAN-CD4

CD4 Sun Hydraulics ISO 08: On A with reverse flow check Sandwich manifold drawing CD4 – Sun Hydraulics ISO 08: On A with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FQGAXAN-CD4

RPES8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPES8-WN – Sun Hydraulics Pilot-operated, balanced poppet relief main stage with integral T-8A control cavity - Standard Material/Coating
Assembly:

RPES8WN-ZDD

ZDD Sun Hydraulics Flange mount through port Line mount manifold drawing ZDD – Sun Hydraulics Flange mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPES8WN-ZDD

CBFB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFBLHN-WSZ

WSZ Sun Hydraulics Through port 2 with gauge port Line mount manifold drawing WSZ – Sun Hydraulics Through port 2 with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFBLHN-WSZ

FQIA-XAN Sun Hydraulics Flow fuse Valve – installation dimensions drawing, cavity T-18A FQIA-XAN – Sun Hydraulics Fixed-orifice, flow fuse valve - Standard Material/Coating
Assembly:

FQIAXAN-LAF

LAF Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing LAF – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FQIAXAN-LAF

DFFA8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFA8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2 - Standard Material/Coating
Assembly:

DFFA8DN-W2T

W2T Sun Hydraulics With bypass compensator Line mount manifold drawing W2T – Sun Hydraulics With bypass compensator Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFFA8DN-W2T

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-CBJ

CBJ Sun Hydraulics ISO 05: Meter in with restrictive compensator and LS shuttle Sandwich manifold drawing CBJ – Sun Hydraulics ISO 05: Meter in with restrictive compensator and LS shuttle Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDALHN-CBJ

FMDF-XDN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-11A FMDF-XDN – Sun Hydraulics Electro-proportional 3-way flow control valve, meter in (740 Series) - 211 – DIN 43650-Form A, 115 VAC
Assembly:

FMDFXDN211-A2B

A2B Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2B – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FMDFXDN211-A2B

CBAG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAG-LJN – Sun Hydraulics 4.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAGLJN-A2A

A2A Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2A – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAGLJN-A2A

NQEB-XAN Sun Hydraulics Air bleed and start-up Valve – installation dimensions drawing, cavity T-3A NQEB-XAN – Sun Hydraulics Air bleed and start-up valve - Standard Material/Coating
Assembly:

NQEBXAN-CAT

CAT Sun Hydraulics Ninety degree Line mount manifold drawing CAT – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

NQEBXAN-CAT

CBAA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAA-LHN – Sun Hydraulics 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAALHN-C5U

C5U Sun Hydraulics Through port 1 with gauge port, accepts standard and weatherized coils Line mount manifold drawing C5U – Sun Hydraulics Through port 1 with gauge port, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAALHN-C5U

Back To Shop

Cart totals

Subtotal
Total

Main Menu