Product Price Quantity Total  
CAIK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAIKLHN-K25/W3

K25 Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing K25 – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /W3 – 65-45-12 Ductile Iron, Metric, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CAIKLHN-K25/W3

CXJA-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-18A CXJA-XCN – Sun Hydraulics Free flow nose to side check valve - Standard Material/Coating
Assembly:

CXJAXCN-ZJZ/Y3

ZJZ Sun Hydraulics Sandwich mount through port Line mount manifold drawing ZJZ – Sun Hydraulics Sandwich mount through port Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CXJAXCN-ZJZ/Y3

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-VWZ/Y3

VWZ Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross pilot with shuttle Motor mount manifold drawing VWZ – Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross pilot with shuttle Motor mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CAEGLGN-VWZ/Y3

CAEA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEALHN-WND/Y4

WND Sun Hydraulics Danfoss OMS: Cross pilot on B Motor mount manifold drawing WND – Sun Hydraulics Danfoss OMS: Cross pilot on B Motor mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CAEALHN-WND/Y4

CWIL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-24A CWIL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWILLGN-ZKY/Y4

ZKY Sun Hydraulics Direct mount, parallel cavities Line mount manifold drawing ZKY – Sun Hydraulics Direct mount, parallel cavities Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CWILLGN-ZKY/Y4

CNEC-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-5A CNEC-XCN – Sun Hydraulics Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check - Standard Material/Coating
Assembly:

CNECXCN-ZHG/S3

ZHG Sun Hydraulics Direct mount Line mount manifold drawing ZHG – Sun Hydraulics Direct mount Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CNECXCN-ZHG/S3

RPEN-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEN-LAN – Sun Hydraulics Electro-proportional relief valve - high pressure setting with no command (740 Series) - No coil
Assembly:

RPENLAN-WLY/Y4

WLY Sun Hydraulics Danfoss OMT: Cross port Motor mount manifold drawing WLY – Sun Hydraulics Danfoss OMT: Cross port Motor mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

RPENLAN-WLY/Y4

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-BB2/Y

BB2 Sun Hydraulics ISO 05: Reducer on A with reverse flow check Sandwich manifold drawing BB2 – Sun Hydraulics ISO 05: Reducer on A with reverse flow check Sandwich manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CBDBXNN-BB2/Y

CNFC-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-5A CNFC-XCN – Sun Hydraulics Free flow nose to side check valve with bypass orifice - Standard Material/Coating
Assembly:

CNFCXCN-ZHG/S3

ZHG Sun Hydraulics Direct mount Line mount manifold drawing ZHG – Sun Hydraulics Direct mount Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CNFCXCN-ZHG/S3

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-BB2/Y5

BB2 Sun Hydraulics ISO 05: Reducer on A with reverse flow check Sandwich manifold drawing BB2 – Sun Hydraulics ISO 05: Reducer on A with reverse flow check Sandwich manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CBDBXNN-BB2/Y5

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-BBF/Y3

BBF Sun Hydraulics ISO 05: On A or B, port 3 external Sandwich manifold drawing BBF – Sun Hydraulics ISO 05: On A or B, port 3 external Sandwich manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CAEKLHN-BBF/Y3

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-B7V/Y3

B7V Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing B7V – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDDXXN-B7V/Y3

DKJR8-HN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DKJR8-HN – Sun Hydraulics Normally closed, balanced poppet, logic element with integral T-8A control cavity - vent-to-open - N – Buna-N
Assembly:

DKJR8HN-ZKY/W5

ZKY Sun Hydraulics Direct mount, parallel cavities Line mount manifold drawing ZKY – Sun Hydraulics Direct mount, parallel cavities Line mount manifold - /W5 – 65-45-12 Ductile Iron, Metric, Viton, Electroless Nickel
Assembly:

DKJR8HN-ZKY/W5

CXID-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-18A CXID-XCN – Sun Hydraulics Free flow side to nose check valve - Standard Material/Coating
Assembly:

CXIDXCN-LN8/W3

LN8 Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing LN8 – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /W3 – 65-45-12 Ductile Iron, Metric, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CXIDXCN-LN8/W3

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-5BD/Y3

5BD Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold drawing 5BD – Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDDXXN-5BD/Y3

CNCC-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-13A CNCC-XCN – Sun Hydraulics Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check - Standard Material/Coating
Assembly:

CNCCXCN-U8W

U8W Sun Hydraulics Common port 1 with coil clearance Line mount manifold drawing U8W – Sun Hydraulics Common port 1 with coil clearance Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CNCCXCN-U8W

DFEA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - No coil
Assembly:

DFEAXCN-ZKV/Y4

ZKV Sun Hydraulics Sandwich mount through port Line mount manifold drawing ZKV – Sun Hydraulics Sandwich mount through port Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

DFEAXCN-ZKV/Y4

DFFJ-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFJ-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series) - No coil
Assembly:

DFFJXCN-LN8/W3

LN8 Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing LN8 – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /W3 – 65-45-12 Ductile Iron, Metric, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

DFFJXCN-LN8/W3

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-YAO/Y1

YAO Sun Hydraulics Direct mount, cross pilot Line mount manifold drawing YAO – Sun Hydraulics Direct mount, cross pilot Line mount manifold - /Y1 – 65-45-12 Ductile Iron, Viton, Clear Zinc Nickel with Top Sealer
Assembly:

CAEKLHN-YAO/Y1

Back To Shop

Cart totals

Subtotal
Total

Main Menu