Product Price Quantity Total  
DFFA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - 211 – DIN 43650-Form A, 115 VAC
Assembly:

DFFAXCN211-LA7

LA7 Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing LA7 – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFFAXCN211-LA7

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-ZTS

ZTS Sun Hydraulics Nipple mount Line mount manifold drawing ZTS – Sun Hydraulics Nipple mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAAXNN-ZTS

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-BNV

BNV Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing BNV – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-BNV

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-XBB

XBB Sun Hydraulics Cross port with shuttle on port 3s Line mount manifold drawing XBB – Sun Hydraulics Cross port with shuttle on port 3s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDAXNN-XBB

DAAH-BCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-8A DAAH-BCN – Sun Hydraulics 2-way, hydraulically operated, spool directional valve - pilot capacity - Standard Material/Coating
Assembly:

DAAHBCN-WFN/S5

WFN Sun Hydraulics Ninety degree Line mount manifold drawing WFN – Sun Hydraulics Ninety degree Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

DAAHBCN-WFN/S5

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-E8I

E8I Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold drawing E8I – Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-E8I

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-C6K

C6K Sun Hydraulics Ninety degree with high capacity port 3, gauge port, accepts standard and weatherized coils Line mount manifold drawing C6K – Sun Hydraulics Ninety degree with high capacity port 3, gauge port, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABXNN-C6K

CBGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGA-LHN – Sun Hydraulics 3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGALHN-WED

WED Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold drawing WED – Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBGALHN-WED

CBHA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHALHN-VFT

VFT Sun Hydraulics Sandwich mount through port Line mount manifold drawing VFT – Sun Hydraulics Sandwich mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBHALHN-VFT

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-B6D

B6D Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing B6D – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-B6D

CABN-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABN-LHN – Sun Hydraulics 7:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CABNLHN-C3C

C3C Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing C3C – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABNLHN-C3C

CWEL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-22A CWEL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWELLGN-N4C

N4C Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4C – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CWELLGN-N4C

CBDB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBLHN-ZSA

ZSA Sun Hydraulics Flange mount through port Line mount manifold drawing ZSA – Sun Hydraulics Flange mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBLHN-ZSA

PVDA-LAN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-21A PVDA-LAN – Sun Hydraulics Pilot-operated, pressure reducing/relieving valve with drain to port 4 - Standard Material/Coating
Assembly:

PVDALAN-M4U

M4U Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4U – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PVDALAN-M4U

LOJOZ-DN Sun Hydraulics Position Indication Valve – installation dimensions drawing, cavity T-19A LOJOZ-DN – Sun Hydraulics Pilot-to-close, spring-biased open, unbalanced poppet logic element with position switch - V – Viton
Assembly:

LOJOZDV-K26

K26 Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K26 – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LOJOZDV-K26

PPJB-LAN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-19A PPJB-LAN – Sun Hydraulics Pilot-operated, pressure reducing/relieving valve - Standard Material/Coating
Assembly:

PPJBLAN-K2F

K2F Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2F – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PPJBLAN-K2F

CAEA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEALHN-XVB

XVB Sun Hydraulics Eaton/Char-Lynn 2000-2speed: Cross pilot with shuttle Motor mount manifold drawing XVB – Sun Hydraulics Eaton/Char-Lynn 2000-2speed: Cross pilot with shuttle Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEALHN-XVB

DFEI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFEIXCN-CDD/W

CDD Sun Hydraulics ISO 08: B to T Sandwich manifold drawing CDD – Sun Hydraulics ISO 08: B to T Sandwich manifold - /W – 65-45-12 Ductile Iron, Metric, Viton, Dewatering Oil
Assembly:

DFEIXCN-CDD/W

CVIV-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-24A CVIV-XCN – Sun Hydraulics Vented pilot-to-open check valve - Standard Material/Coating
Assembly:

CVIVXCN-QAE

QAE Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing QAE – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CVIVXCN-QAE

CNKC-XAN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-18AU CNKC-XAN – Sun Hydraulics Free flow nose to side check valve with bypass orifice - N – Buna-N
Assembly:

CNKCXAN-LBR

LBR Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing LBR – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CNKCXAN-LBR

RBAA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBAA-LAN – Sun Hydraulics Direct-acting relief valve - pilot capacity - Standard Material/Coating
Assembly:

RBAALAN-ZKA/S3

ZKA Sun Hydraulics Flange mount through port Line mount manifold drawing ZKA – Sun Hydraulics Flange mount through port Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RBAALAN-ZKA/S3

RPEC-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEC-LAN – Sun Hydraulics Pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPECLAN-FAU/S3

FAU Sun Hydraulics Ninety degree Line mount manifold drawing FAU – Sun Hydraulics Ninety degree Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RPECLAN-FAU/S3

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-B7K

B7K Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing B7K – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-B7K

CBFG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFGLJN-ZEK

ZEK Sun Hydraulics Ninety degree Line mount manifold drawing ZEK – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFGLJN-ZEK

MAEP-DHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A MAEP-DHN – Sun Hydraulics Atmospherically referenced LoadMatch™ counterbalance valve - Standard Material/Coating
Assembly:

MAEPDHN-4BK

4BK Sun Hydraulics Cushion lock with make up checks Line mount manifold drawing 4BK – Sun Hydraulics Cushion lock with make up checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

MAEPDHN-4BK

RGFA-LCN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RGFA-LCN – Sun Hydraulics Low-pressure-range, direct-acting relief valve - Standard Material/Coating
Assembly:

RGFALCN-CCX

CCX Sun Hydraulics P to T, manifold P and T ports Sub plate manifold drawing CCX – Sun Hydraulics P to T, manifold P and T ports Sub plate manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RGFALCN-CCX

RPEE-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEE-LAN – Sun Hydraulics Fast-acting, pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPEELAN-FEZ

FEZ Sun Hydraulics Through port with gauge port Line mount manifold drawing FEZ – Sun Hydraulics Through port with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPEELAN-FEZ

DCEC-XCN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity T-63A DCEC-XCN – Sun Hydraulics 4-way, 3-position, pilot-to-shift directional valve - Standard Material/Coating
Assembly:

DCECXCN-PPD/S

PPD Sun Hydraulics Ninety degree Line mount manifold drawing PPD – Sun Hydraulics Ninety degree Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

DCECXCN-PPD/S

DKFS-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-22A DKFS-XHN – Sun Hydraulics Normally closed, balanced poppet, logic element - pilot-to-open - Standard Material/Coating
Assembly:

DKFSXHN-XIL/S3

XIL Sun Hydraulics Cross pilot with common port 4s Line mount manifold drawing XIL – Sun Hydraulics Cross pilot with common port 4s Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DKFSXHN-XIL/S3

FPBN-XDN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-162A FPBN-XDN – Sun Hydraulics FLeX Series pilot-operated, normally open, electro-proportional throttle with reverse flow check - flow 2-1 - 3000 psi (210 bar) - 212L – DIN 43650-Form A, 12 VDC, low power
Assembly:

FPBNXDN212L-ABA

ABA Sun Hydraulics ISO 02: P to T Sandwich manifold drawing ABA – Sun Hydraulics ISO 02: P to T Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FPBNXDN212L-ABA

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-EEU

EEU Sun Hydraulics Port 3 connected to port 1 Line mount manifold drawing EEU – Sun Hydraulics Port 3 connected to port 1 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABKLHN-EEU

CBFG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFGLJN-H4E

H4E Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing H4E – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFGLJN-H4E

RDFA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RDFA-LAN – Sun Hydraulics Direct-acting relief valve - /AP – Stainless Steel, Passivated
Assembly:

RDFALAN/AP-CA5

CA5 Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing CA5 – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RDFALAN/AP-CA5

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-BDJ

BDJ Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing BDJ – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDALHN-BDJ

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-BTV

BTV Sun Hydraulics On P, port 3 to T, manifold T port Sub plate manifold drawing BTV – Sun Hydraulics On P, port 3 to T, manifold T port Sub plate manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDAXNN-BTV

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-YAO/S3

YAO Sun Hydraulics Direct mount, cross pilot Line mount manifold drawing YAO – Sun Hydraulics Direct mount, cross pilot Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDCLHN-YAO/S3

RPEE-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEE-LAN – Sun Hydraulics Fast-acting, pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPEELAN-FNT

FNT Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing FNT – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPEELAN-FNT

DFEB-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEB-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 - No coil
Assembly:

DFEBXCN-ICN/S3

ICN Sun Hydraulics Inline Line mount manifold drawing ICN – Sun Hydraulics Inline Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DFEBXCN-ICN/S3

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-C2K

C2K Sun Hydraulics Ninety degree with high capacity port 3, accepts standard and weatherized coils Line mount manifold drawing C2K – Sun Hydraulics Ninety degree with high capacity port 3, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAAXNN-C2K

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-B6B

B6B Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing B6B – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDALHN-B6B

CBAA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAA-LHN – Sun Hydraulics 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAALHN-EDU

EDU Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing EDU – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAALHN-EDU

CXJA-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-18A CXJA-XCN – Sun Hydraulics Free flow nose to side check valve - Standard Material/Coating
Assembly:

CXJAXCN-LE8

LE8 Sun Hydraulics Through port with gauge port Line mount manifold drawing LE8 – Sun Hydraulics Through port with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXJAXCN-LE8

RPET-LWN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPET-LWN – Sun Hydraulics Anti-Shock, pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPETLWN-X5N

X5N Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing X5N – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPETLWN-X5N

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-X4D

X4D Sun Hydraulics Through port 3 Line mount manifold drawing X4D – Sun Hydraulics Through port 3 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-X4D

RBUY-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity SC-10-02 RBUY-LAN – Sun Hydraulics Bi-directional, direct-acting relief valve - common cavity - V – Viton
Assembly:

RBUYLAV-JNC

JNC Sun Hydraulics Ninety degree Line mount manifold drawing JNC – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RBUYLAV-JNC

DFCA8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-13A DFCA8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2 - Standard Material/Coating
Assembly:

DFCA8DN-XWL

XWL Sun Hydraulics Bidirectional Line mount manifold drawing XWL – Sun Hydraulics Bidirectional Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFCA8DN-XWL

DFEI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFEIXCN-CKD/S3

CKD Sun Hydraulics ISO 07: A to T with gage port Sandwich manifold drawing CKD – Sun Hydraulics ISO 07: A to T with gage port Sandwich manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DFEIXCN-CKD/S3

CAEA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEALHN-WPC

WPC Sun Hydraulics All gasket ports Gasket mount manifold drawing WPC – Sun Hydraulics All gasket ports Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEALHN-WPC

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-E9U

E9U Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold drawing E9U – Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-E9U

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-XEJ

XEJ Sun Hydraulics Inline, cross pilot Line mount manifold drawing XEJ – Sun Hydraulics Inline, cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-XEJ

Back To Shop

Cart totals

Subtotal
Total

Main Menu