RVCMLJN211 – Sun Hydraulics FLeX Series 2-stage, solenoid-operated adjustable relief valve, energize to block, DIN 43650-Form A, 115 VAC
Part number: RVCMLJN · RVCM-LJN · RVCM LJN
FLeX Series 2-stage, solenoid-operated adjustable relief valve, energize to block. Cavity T-10A, capacity 25 gpm (95 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.
RVCM-LJN overview
RVCMLJN (RVCM-LJN, RVCM LJN) is a Sun Hydraulics Sun Hydraulics FLeX Series 2-stage, solenoid-operated adjustable relief valve, energize to block, rated 25 gpm (95 L/min.) and installed in cavity T-10A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.
Ordering codes
Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.
| RVCMLJN | No coilNo coil |
|---|---|
| RVCMLJN211 | DIN 43650-Form A, 115 VACDIN 43650-Form A, 115 VAC |
| RVCMLJN212 | DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC |
| RVCMLJN212D | DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodesDIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes |
Specifications
| Cavity | T-10A |
|---|---|
| Series | 1 |
| Capacity | 25 gpm (95 L/min.) |
| Maximum Operating Pressure | 5000 psi (350 bar) |
| Factory Pressure Settings Established at | 4 gpm (15 L/min.) |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 5 in³/min.@3000 psi (80 cc/min.@210 bar) |
| Response Time - Typical | 50 ms |
| Response Time - Typical (Relief) | 10 ms |
| Adjustment - No. of CW Turns from Min. to Max. setting | 3.5 |
| Valve Hex Size | 7/8 in. (22,2 mm) |
| Valve Installation Torque | 30 - 35 lbf ft (41 - 47 Nm) |
| Adjustment Screw Internal Hex Size | 1/8 in. (3,2 mm) |
| Locknut Hex Size | 7/16 in. (11,1 mm) |
| Locknut Torque | 45 - 55 lbf in. (5 - 6 Nm) |
| Model Weight | .40 lb (0,20 kg) |
| U.S. Patent # | 10,570,932 |
| Seal kit - Cartridge | Viton: 990010006 |
How to read RVCMLJN
Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so RVCMLJN, RVCM-LJN, RVCM LJN are the same part.
| Model | RVCM — Sun Hydraulics FLeX Series 2-stage, solenoid-operated adjustable relief valve, energize to block |
|---|---|
| Control | L — Standard Screw Adjustment |
| Adjustment Range | J — 300 - 5000 psi (20 - 350 bar), 1000 psi (70 bar) Standard Setting |
| Seal Material | N — Buna-N |
| Material / coating | Add /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish. |
Control options
- L — Standard Screw Adjustment
Adjustment Range options
- J — 300 - 5000 psi (20 - 350 bar), 1000 psi (70 bar) Standard Setting
Seal Material options
- N — Buna-N
- V — Viton
- E — EPDM
Coil options
- — No coil
- 211 — DIN 43650-Form A, 115 VAC
- 212 — DIN 43650-Form A, 12 VDC
- 212D — DIN 43650-Form A, 12 VDC, with transient voltage suppression (TVS) diodes
- 214 — DIN 43650-Form A, 14 VDC
- 214D — DIN 43650-Form A, 14 VDC, with transient voltage suppression (TVS) diodes
- 223 — DIN 43650-Form A, 230 VAC
- 224 — DIN 43650-Form A, 24 VDC
- 224D — DIN 43650-Form A, 24 VDC, with transient voltage suppression (TVS) diodes
- 228 — DIN 43650-Form A, 28 VDC
- 228D — DIN 43650-Form A, 28 VDC, with transient voltage suppression (TVS) diodes
- 612 — AMP Junior Timer, 12 VDC
- 612D — AMP Junior Timer, 12 VDC, with transient voltage suppression (TVS) diodes
- 614 — AMP Junior Timer, 14 VDC
- 614D — AMP Junior Timer, 14 VDC, with transient voltage suppression (TVS) diodes
- 624 — AMP Junior Timer, 24 VDC
- 624D — AMP Junior Timer, 24 VDC, with transient voltage suppression (TVS) diodes
- 628 — AMP Junior Timer, 28 VDC
- 628D — AMP Junior Timer, 28 VDC, with transient voltage suppression (TVS) diodes
- 712 — Twin Lead, 12 VDC
- 712D — Twin Lead, 12 VDC, with transient voltage suppression (TVS) diodes
- 714 — Twin Lead, 14 VDC
- 714D — Twin Lead, 14 VDC, with transient voltage suppression (TVS) diodes
- 724 — Twin Lead, 24 VDC
- 724D — Twin Lead, 24 VDC, with transient voltage suppression (TVS) diodes
- 728 — Twin Lead, 28 VDC
- 728D — Twin Lead, 28 VDC, with transient voltage suppression (TVS) diodes
- 812 — Metri-Pack, 12 VDC
- 812D — Metri-Pack, 12 VDC, with transient voltage suppression (TVS) diodes
- 814 — Metri-Pack, 14 VDC
- 814D — Metri-Pack, 14 VDC, with transient voltage suppression (TVS) diodes
- 824 — Metri-Pack, 24 VDC
- 824D — Metri-Pack, 24 VDC, with transient voltage suppression (TVS) diodes
- 828 — Metri-Pack, 28 VDC
- 828D — Metri-Pack, 28 VDC, with transient voltage suppression (TVS) diodes
- 912 — Deutsch DT04-2P, 12 VDC
- 912D — Deutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodes
- 914 — Deutsch DT04-2P, 14 VDC
- 914D — Deutsch DT04-2P, 14 VDC, with transient voltage suppression (TVS) diodes
- 924 — Deutsch DT04-2P, 24 VDC
- 924D — Deutsch DT04-2P, 24 VDC, with transient voltage suppression (TVS) diodes
- 928 — Deutsch DT04-2P, 28 VDC
- 928D — Deutsch DT04-2P, 28 VDC, with transient voltage suppression (TVS) diodes
- JM24BD — Explosion Proof, Metric (M20 X 1.5), 24 VDC, 180 Degree, CSA and ATEX Certification
- JM24CD — Explosion Proof, Metric (M20 X 1.5), 24 VDC, 90 Degree, CSA and ATEX Certification
- JN24BD — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 180 Degree, CSA and ATEX Certification
- JN24CD — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 90 Degree, CSA and ATEX Certification
Manifold & standard assemblies
Sun manifolds for cavity T-10A (293)
- CBD Sun Hydraulics ISO 05: A and B to T Sandwich manifoldRVCMLJN211-CBD — request assembly
- CBE Sun Hydraulics ISO 05: P to T Sandwich manifoldRVCMLJN211-CBE — request assembly
- CBF Sun Hydraulics ISO 05: A to T Sandwich manifoldRVCMLJN211-CBF — request assembly
- CBG Sun Hydraulics ISO 05: B to T Sandwich manifoldRVCMLJN211-CBG — request assembly
- CBH Sun Hydraulics ISO 05: A to B or B to A Sandwich manifoldRVCMLJN211-CBH — request assembly
- CBI Sun Hydraulics ISO 05: A to B and B to A Sandwich manifoldRVCMLJN211-CBI — request assembly
- CJY Sun Hydraulics ISO 05 – X&Y: A to B and B to A Sandwich manifoldRVCMLJN211-CJY — request assembly
- FA3 Sun Hydraulics Ninety degree Line mount manifoldRVCMLJN211-FA3 — request assembly
- FA4 Sun Hydraulics Ninety degree Line mount manifoldRVCMLJN211-FA4 — request assembly
- FAA Sun Hydraulics Ninety degree Line mount manifoldRVCMLJN211-FAA — request assembly
- FAB Sun Hydraulics Ninety degree Line mount manifoldRVCMLJN211-FAB — request assembly
- FAC Sun Hydraulics Ninety degree Line mount manifoldRVCMLJN211-FAC — request assembly
Technical features
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Designed and tested to 10-million operational cycles at full-rated pressure.
- Exceeds new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
- Higher flow rates than competing valves of similar size.
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
- This cartridge utilizes both 740 Series high-power and 747 Series hazardous location coils.
- Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
- Main stage orifice is protected by a 150-micron stainless steel screen.
- Will accept maximum pressure at port 2.
- All configurations of this valve are assembled with a non-removable adjust screw.
- FLeX Series relief valves are fully compatible with the XMD Expandable Mobile Drivers from Sun.
- A FULL DATA SHEET is available for this model using the link at the top of the page.
- A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Drawings, symbol & performance curves
Downloads
Datasheet
Technical reference sheets
- 747_Series_Coils_CoC-CSA (PDF 106 KB)
- 747_Series_Coils_Sira_16ATEX1091X_Iss1 (PDF 977 KB)
- 999-901-334 (PDF 344 KB)
- FloatingStyleScrewInCartridge2 (PDF 1 MB)
- TT_US_Cavity-New (PDF 522 KB)
- TT_US_Relief-N (PDF 656 KB)
CAD files
Frequently asked questions
Is RVCMLJN the same as RVCM-LJN?
Yes. Sun Hydraulics writes this part number as RVCMLJN. It is the model RVCM followed by the configuration code; hyphens, slashes and spaces are only dividers, so RVCMLJN, RVCM-LJN, RVCM LJN all refer to the same product.
Do you supply RVCMLJN in the UAE, GCC and India?
Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including RVCMLJN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.
Can I get the datasheet and CAD files?
Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.
Where would I use a kick-down relief?
One graphic example is on a portable grain auger for silos. When the farmer gets caught in the auger the kick-down relief trips and allows him to escape.
What are the tolerances on pressure settings for Sun's pressure control valves?
Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page.
How big is a drop of hydraulic oil?
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Can I use a kick-down relief for my system relief?
Maybe not. We build in a good amount of overlap in the kick-down reliefs to prevent false tripping. This means they are not as fast as our standard pilot-operated reliefs. A direct-acting relief valve set just above the kick-down relief valve would be good insurance.
Direct acting or pilot operated - what do I use?
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
What is the difference between nominal and maximum flow capacity?
What parts of the Sun cartridge valve are field serviceable?
Is the FLeX program available in QuickDesign SmartConnect?
Yes. All FLeX phase 1 valves are available in the SmartConnect schematic tool, and are also available for submittal to QuickDesign.
Do FLeX valves utilize a floating nose design?
Manufacturer reference: https://www.sunhydraulics.com/model/RVCM