PSDLMDN212 – Sun Hydraulics Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition and drain to port 4, DIN 43650-Form A, 12 VDC

Part number: PSDLMDN · PSDL-MDN · PSDL MDN

Brand Sun HydraulicsType Reducing/RelievingCapacity 5 gpm (20 L/min.)Cavity T-21A

Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition and drain to port 4. Cavity T-21A, capacity 5 gpm (20 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: PSDL Category: Brand:

PSDL-MDN overview

PSDLMDN (PSDL-MDN, PSDL MDN) is a Sun Hydraulics Sun Hydraulics Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition and drain to port 4, rated 5 gpm (20 L/min.) and installed in cavity T-21A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

PSDLMDN No coilNo coil
PSDLMDN212 DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC
PSDLMDN212N DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodesDIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes
PSDLMDN212NX01 DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driverDIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver

Specifications

CavityT-21A
Series1
Capacity5 gpm (20 L/min.)
Maximum Operating Pressure5000 psi (350 bar)
Maximum Valve Leakage at 110 SUS (24 cSt)20 in³/min. (330 cc/min.)
Adjustment - No. of CW Turns from Min. to Max. setting5
Solenoid Tube Diameter.75 in. (19 mm)
Valve Hex Size7/8 in. (22,2 mm)
Valve Installation Torque30 - 35 lbf ft (41 - 47 Nm)
Adjustment Screw Internal Hex Size5/32 in. (4 mm)
Locknut Hex Size9/16 in. (15 mm)
Locknut Torque80 - 90 lbf in. (9 - 10 Nm)
Model Weight (with coil)1.20 lb (0,55 kg)
Seal kit - CartridgeViton: 990021006
Seal and nut kit - CoilViton: 990770006

Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.

How to read PSDLMDN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so PSDLMDN, PSDL-MDN, PSDL MDN are the same part.

ModelPSDL — Sun Hydraulics Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition and drain to port 4
ControlM — Manual Override (Standard)
Operating RangeD — 50 - 485 psi (3,5 - 33,5 bar)
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Control options
  • L — Standard Screw Adjustment
  • M — Manual Override (Standard)
Operating Range options
  • B — 100 - 1125 psi (7 - 77,5 bar)
  • D — 50 - 485 psi (3,5 - 33,5 bar)
  • E — 25 - 250 psi (1,7 - 18 bar)
  • S — 10 - 100 psi (0,7 - 7 bar)
Seal Material options
  • N — Buna-N
  • V — Viton
Coil options
  • — No coil
  • 212 — DIN 43650-Form A, 12 VDC
  • 212N — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes
  • 212NX01 — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 212NX02 — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 214N — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes
  • 214NX01 — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 214NX02 — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 224 — DIN 43650-Form A, 24 VDC
  • 224N — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes
  • 224NX01 — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 224NX02 — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 2B12A — DIN 43650-Form A, command common on fourth pin, 12 VDC, 0-20 mA
  • 2B12B — DIN 43650-Form A, command common on fourth pin, 12 VDC, Bluetooth
  • 2B12V — DIN 43650-Form A, command common on fourth pin, 12 VDC, 0-10V
  • 2B24A — DIN 43650-Form A, command common on fourth pin, 24 VDC, 0-20 mA
  • 2B24B — DIN 43650-Form A, command common on fourth pin, 24 VDC, Bluetooth
  • 2B24V — DIN 43650-Form A, command common on fourth pin, 24 VDC, 0-10V
  • 2C12V — DIN 43650-Form A, +5V reference on fourth pin, 12 VDC, 0-10V
  • 2C24V — DIN 43650-Form A, +5V reference on fourth pin, 24 VDC, 0-10V
  • 2D12A — DIN 43650-Form A, enable input on fourth pin, 12 VDC, 0-20 mA
  • 2D24A — DIN 43650-Form A, enable input on fourth pin, 24 VDC, 0-20 mA
  • 2D24V — DIN 43650-Form A, enable input on fourth pin, 24 VDC, 0-10V
  • 2F12V — DIN 43650-Form A, programmable ramps, separate rise and fall, 12 VDC
  • 2F24V — DIN 43650-Form A, programmable ramps, separate rise and fall, 24 VDC
  • 4A12A — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, 0-20 mA
  • 4A12B — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, Bluetooth
  • 4A12V — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, 0-10V
  • 4A24A — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, 0-20 mA
  • 4A24B — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, Bluetooth
  • 4A24V — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, 0-10V
  • 4F12V — Deutsch DT04-6P, programmable ramps, separate rise and fall, 12 VDC
  • 4F24V — Deutsch DT04-6P, programmable ramps, separate rise and fall, 24 VDC
  • 812 — Metri-Pack, 12 VDC
  • 912 — Deutsch DT04-2P, 12 VDC
  • 912N — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes
  • 912NX01 — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 912NX02 — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 914NX01 — Deutsch DT04-2P, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 914NX02 — Deutsch DT04-2P, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 924 — Deutsch DT04-2P, 24 VDC
  • 924N — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes
  • 924NX01 — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 924NX02 — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • HN24AA — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 10 feet twin lead, ATEX Certification Ex mb IIC T3 Gb.
  • HN24AB — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 10 feet twin lead, CSA Certification

Manifold & standard assemblies

Sun manifolds for cavity T-21A (54)

View all 54 →

Technical features

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Uses for the 'L' manual screw adjustment include: emergency valve setting during power failure or alternatively boosting the valve setting
  • With the 'L' adjustment screw, all ranges are factory set at zero (adjustment screw fully backed out). With the coil de-energized, clockwise adjustment of the screw will increase the spring bias load up to the maximum setting for that range. With the coil energized, any mechanical pressure setting is directly additive to the coil induced value.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Drawings, symbol & performance curves

PSDL-MDN Sun Hydraulics Reducing/Relieving Valve – hydraulic schematic symbol
hydraulic schematic symbol
PSDL-MDN Sun Hydraulics Reducing/Relieving Valve – hydraulic schematic symbol
hydraulic schematic symbol
PSDL-MDN Sun Hydraulics Reducing/Relieving Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
PSDL-MDN Sun Hydraulics Reducing/Relieving Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
PSDL-MDN Sun Hydraulics Reducing/Relieving Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
PSDLMDN Sun Hydraulics Reducing/Relieving Valve – 2D outline drawing
2D outline drawing

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is PSDLMDN the same as PSDL-MDN?

Yes. Sun Hydraulics writes this part number as PSDLMDN. It is the model PSDL followed by the configuration code; hyphens, slashes and spaces are only dividers, so PSDLMDN, PSDL-MDN, PSDL MDN all refer to the same product.

Do you supply PSDLMDN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including PSDLMDN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

Direct acting or pilot operated - what do I use?

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Can I back flow through a reducing valve from port 1 to port 2?

Yes. A reducing or reducing/relieving valve is normally open. If the pressure in the secondary circuit is less than the setting, it will be open.

2 caveats: (1) If the valve is in the reducing mode and you suddenly reverse the flow, the valve will not have time to open and will shift into relieving mode or (2) If the back flow generates a pressure drop through the valve that exceeds the setting, the valve will shift into the relieving mode.

When in doubt, use a reverse flow check.

What are the tolerances on pressure settings for Sun's pressure control valves?

Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page.

I need a reducer on B. Can I connect the drain to A?

Yes. If you look in the sandwich section you will see that we offer many such packages. When you are pressurizing B, A is connected to tank, allowing the reducer to do its job. When you reverse, the drain or tank port of the reducer is pressurized by A. This increases the setting of the reducer and helps keep the reducer open in the reverse flow direction.

What do you mean by maximum differential?

Our reducing valves are outside-in valves; the supply pressure on the outside of the working parts is higher than the inside. At some pressure differential, the outside (sleeve) will close in on the piston and cause the valve to stick. A D range is adjustable from 25 to 800 psi with a maximum differential of 2000 psi. This means you could set the valve at 600 psi and expect it to work correctly with a supply pressure of 2600 psi. The valve may work at higher differentials, but we do not recommend it. The W and C ranges are tested over their entire range with an inlet pressure of 5000 psi. All direct-acting valves are tested with an inlet pressure of 5000 psi.

Will your reducing/relieving valve relieve my pump to tank?

No. A reducing/relieving valve throttles a supply of oil to maintain a set pressure in a secondary circuit. The valve is open until the secondary or downstream pressure rises to the setting of the valve at which time it starts to close to limit the pressure. If the secondary or downstream pressure is caused to go above the setting, the valve shifts into relieving mode and throttles the secondary circuit back to tank to prevent over-pressure. At no time can the valve connect the supply to tank.

How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

Manufacturer reference: https://www.sunhydraulics.com/model/PSDL