PRTSXDN – Sun Hydraulics Electro-proportional, direct-acting pressure reducing/relieving valve with filter screen, 3000 psi (210 bar) - common cavity, No coil

Part number: PRTSXDN · PRTS-XDN · PRTS XDN

Brand Sun HydraulicsType Reducing/RelievingCapacity 1 gpm (4 L/min.)Cavity SC-08-03

Electro-proportional, direct-acting pressure reducing/relieving valve with filter screen, 3000 psi (210 bar) – common cavity. Cavity SC-08-03, capacity 1 gpm (4 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: PRTS Category: Brand:

PRTS-XDN overview

PRTSXDN (PRTS-XDN, PRTS XDN) is a Sun Hydraulics Sun Hydraulics Electro-proportional, direct-acting pressure reducing/relieving valve with filter screen, 3000 psi (210 bar) - common cavity, rated 1 gpm (4 L/min.) and installed in cavity SC-08-03. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

PRTSXDN No coilNo coil
PRTSXDN212 DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC
PRTSXDN224 DIN 43650-Form A, 24 VDCDIN 43650-Form A, 24 VDC
PRTSXDN912D Deutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodesDeutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodes

Specifications

CavitySC-08-03
Series0C
Capacity1 gpm (4 L/min.)
Maximum Operating Pressure3000 psi (210 bar)
Typical Valve Leakage at 110 SUS (24cSt)0.3 in³/min.@3000 psi (4,5 mL/min.@210 bar)
Solenoid Tube Diameter.51 in.
Valve Hex Size7/8 in. (22,2 mm)
Coil Nut Torque3.5 - 3.9 lbf ft (4,8 - 5,3 Nm)
Valve Installation Torque21 - 23 lbf ft (28 - 31 Nm)
Model Weight.35 lb (0,15 kg)

How to read PRTSXDN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so PRTSXDN, PRTS-XDN, PRTS XDN are the same part.

ModelPRTS — Sun Hydraulics Electro-proportional, direct-acting pressure reducing/relieving valve with filter screen, 3000 psi (210 bar) - common cavity
ControlX — -
Adjustment RangeD — 0 - 435 psi
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Control options
  • M — -
  • X — -
Adjustment Range options
  • D — 0 - 435 psi
  • E — 0 - 290 psi
Seal Material options
  • N — Buna-N
Coil options
  • — No coil
  • 212 — DIN 43650-Form A, 12 VDC
  • 224 — DIN 43650-Form A, 24 VDC
  • 912D — Deutsch DT04-2P, 12 VDC, with transient voltage suppression (TVS) diodes
  • 924D — Deutsch DT04-2P, 24 VDC, with transient voltage suppression (TVS) diodes

Manifold & standard assemblies

Sun manifolds for cavity SC-08-03 (12)

Technical features

  • The solenoid tube assembly is fatigue rated for 3000 psi (210 bar) service.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio.
  • This valve features a filter installed on port 2 with a micron rating of 280.
  • Specified leakage is out of port 3, with 3000 psi (210 bar) at port 2 and port 1 deadheaded.
  • For best performance, an amplifier with current sensing and adjustable dither should be used. Recommended dither is 200 Hz.
  • This valve is available with a push-type manual override. There is no upper limit to the pressure setting when using the M control. The more force you exert on the manual override, the higher the resulting pressure. This option is also rated for 3000 psi (210 bar).
  • The cartridge installation torque of 22 lbf ft (30 Nm) should be respected for best performance.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • The metal coil nut is a functional feature of the valve and should be correctly installed for proper performance of the valve.
  • Coil connector options offer ratings up to IP67. See individual coil product pages for details.
  • Coils can be mounted on the tube in either direction.

Drawings, symbol & performance curves

PRTS-XDN Sun Hydraulics Reducing/Relieving Valve – hydraulic schematic symbol
hydraulic schematic symbol
PRTS-XDN Sun Hydraulics Reducing/Relieving Valve – hydraulic schematic symbol
hydraulic schematic symbol
PRTS-XDN Sun Hydraulics Reducing/Relieving Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
PRTS-XDN Sun Hydraulics Reducing/Relieving Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
PRTS-XDN Sun Hydraulics Reducing/Relieving Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
PRTSXDN Sun Hydraulics Reducing/Relieving Valve – 2D outline drawing
2D outline drawing

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is PRTSXDN the same as PRTS-XDN?

Yes. Sun Hydraulics writes this part number as PRTSXDN. It is the model PRTS followed by the configuration code; hyphens, slashes and spaces are only dividers, so PRTSXDN, PRTS-XDN, PRTS XDN all refer to the same product.

Do you supply PRTSXDN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including PRTSXDN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

What are the tolerances on pressure settings for Sun's pressure control valves?

Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page.

I need a reducer on B. Can I connect the drain to A?

Yes. If you look in the sandwich section you will see that we offer many such packages. When you are pressurizing B, A is connected to tank, allowing the reducer to do its job. When you reverse, the drain or tank port of the reducer is pressurized by A. This increases the setting of the reducer and helps keep the reducer open in the reverse flow direction.

What do you mean by maximum differential?

Our reducing valves are outside-in valves; the supply pressure on the outside of the working parts is higher than the inside. At some pressure differential, the outside (sleeve) will close in on the piston and cause the valve to stick. A D range is adjustable from 25 to 800 psi with a maximum differential of 2000 psi. This means you could set the valve at 600 psi and expect it to work correctly with a supply pressure of 2600 psi. The valve may work at higher differentials, but we do not recommend it. The W and C ranges are tested over their entire range with an inlet pressure of 5000 psi. All direct-acting valves are tested with an inlet pressure of 5000 psi.

Will your reducing/relieving valve relieve my pump to tank?

No. A reducing/relieving valve throttles a supply of oil to maintain a set pressure in a secondary circuit. The valve is open until the secondary or downstream pressure rises to the setting of the valve at which time it starts to close to limit the pressure. If the secondary or downstream pressure is caused to go above the setting, the valve shifts into relieving mode and throttles the secondary circuit back to tank to prevent over-pressure. At no time can the valve connect the supply to tank.

How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

Direct acting or pilot operated - what do I use?

Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.

Can I back flow through a reducing valve from port 1 to port 2?

Yes. A reducing or reducing/relieving valve is normally open. If the pressure in the secondary circuit is less than the setting, it will be open.

2 caveats: (1) If the valve is in the reducing mode and you suddenly reverse the flow, the valve will not have time to open and will shift into relieving mode or (2) If the back flow generates a pressure drop through the valve that exceeds the setting, the valve will shift into the relieving mode.

When in doubt, use a reverse flow check.

What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

Manufacturer reference: https://www.sunhydraulics.com/model/PRTS

See It Styled On Instagram