PRHRLAN/LH – Sun Hydraulics Direct-acting, pressure reducing valve, Mild Steel, Zinc-Nickel
Part number: PRHRLAN · PRHR-LAN · PRHR LAN
Direct-acting, pressure reducing valve. Cavity T-17A, capacity 40 gpm (160 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.
PRHR-LAN overview
PRHRLAN (PRHR-LAN, PRHR LAN) is a Sun Hydraulics Sun Hydraulics Direct-acting, pressure reducing valve, rated 40 gpm (160 L/min.) and installed in cavity T-17A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.
Ordering codes
Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.
| PRHRLAN/AP | Stainless Steel, PassivatedStainless Steel, Passivated |
|---|---|
| PRHRLAN/LH | Mild Steel, Zinc-NickelMild Steel, Zinc-Nickel |
| PRHRLAN | Standard Material/CoatingStandard Material/Coating |
Specifications
| Cavity | T-17A |
|---|---|
| Series | 3 |
| Capacity | 40 gpm (160 L/min.) |
| Maximum Operating Pressure | 5000 psi (350 bar) |
| Factory Pressure Settings Established at | 0.25 gpm |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 4 in³/min. (65 cc/min.) |
| Adjustment - No. of CW Turns from Min. to Max. setting | 5 |
| Valve Hex Size | 1 1/4 in. (31,8 mm) |
| Valve Installation Torque | 150 - 160 lbf ft (203 - 217 Nm) |
| Adjustment Screw Internal Hex Size | 5/32 in. (4 mm) |
| Locknut Hex Size | 9/16 in. (15 mm) |
| Locknut Torque | 80 - 90 lbf in. (9 - 10 Nm) |
| Model Weight | 1.50 lb (0,70 kg) |
| Seal kit - Cartridge | Viton: 990017006 |
How to read PRHRLAN
Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so PRHRLAN, PRHR-LAN, PRHR LAN are the same part.
| Model | PRHR — Sun Hydraulics Direct-acting, pressure reducing valve |
|---|---|
| Control | L — Standard Screw Adjustment |
| Adjustment Range | A — 750 - 3000 psi (50 - 210 bar), 1000 psi (70 bar) Standard Setting |
| Seal Material | N — Buna-N |
| Material / coating | Add /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish. |
Control options
- C — Tamper Resistant - Factory Set
- K — Handknob
- L — Standard Screw Adjustment
Adjustment Range options
- A — 750 - 3000 psi (50 - 210 bar), 1000 psi (70 bar) Standard Setting
- B — 300 - 1500 psi (20 - 105 bar), 500 psi (35 bar) Standard Setting
- D — 200 - 800 psi (14 - 55 bar), 400 psi (28 bar) Standard Setting
- E — 100 - 400 psi (7 - 28 bar), 200 psi (14 bar) Standard Setting
- S — 50 - 200 psi (3,5 - 14 bar), 100 psi (7 bar) Standard Setting
- W — 1100 - 4500 psi (76 - 315 bar), 1100 psi (76 bar) Standard Setting
Seal Material options
- L — Extended Temp. Buna
- N — Buna-N
- V — Viton
- E — EPDM
Material/coating options
- /AP — Stainless Steel, Passivated
- /LH — Mild Steel, Zinc-Nickel
- — Standard Material/Coating
Manifold & standard assemblies
Sun manifolds for cavity T-17A (377)
- BJO Sun Hydraulics ISO 05 – X&Y: On P, port 3 to T Sandwich manifoldPRHRLAN/LH-BJO — request assembly
- BK2 Sun Hydraulics ISO 07: Reducer on A with reverse flow check Sandwich manifoldPRHRLAN/LH-BK2 — request assembly
- BK4 Sun Hydraulics ISO 07: Sequence into A with reverse flow check Sandwich manifoldPRHRLAN/LH-BK4 — request assembly
- BK5 Sun Hydraulics ISO 07: Sequence into B with reverse flow check Sandwich manifoldPRHRLAN/LH-BK5 — request assembly
- BK6 Sun Hydraulics ISO 07: Sequence out of A with reverse flow check Sandwich manifoldPRHRLAN/LH-BK6 — request assembly
- BK7 Sun Hydraulics ISO 07: Sequence out of B with reverse flow check Sandwich manifoldPRHRLAN/LH-BK7 — request assembly
- BK8 Sun Hydraulics ISO 07: Cushion lock Sandwich manifoldPRHRLAN/LH-BK8 — request assembly
- BK9 Sun Hydraulics ISO 07: Reducer on A and B with reverse flow check Sandwich manifoldPRHRLAN/LH-BK9 — request assembly
- BKA Sun Hydraulics ISO 07: On A, port 3 to B Sandwich manifoldPRHRLAN/LH-BKA — request assembly
- BKB Sun Hydraulics ISO 07: On B, port 3 to A Sandwich manifoldPRHRLAN/LH-BKB — request assembly
- BKC Sun Hydraulics ISO 07: On A, port 3 external Sandwich manifoldPRHRLAN/LH-BKC — request assembly
- BKJ Sun Hydraulics ISO 07: Reducer on B with reverse flow check Sandwich manifoldPRHRLAN/LH-BKJ — request assembly
Technical features
- Note: This valve has no relieving capability. It should not be used in a dead-headed application. If the reduced pressure side of the circuit has very low leakage the pressure may rise significantly. The pressure rise will vary from valve to valve.
- This type of valve, PR*R, is a good replacement for an LP*C as a normally open, restrictive compensating element if a higher pressure drop across an orifice is needed.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
- Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
- Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Drawings, symbol & performance curves
Downloads
Datasheet
Technical reference sheets
- 999-901-334 (PDF 344 KB)
- FloatingStyleScrewInCartridge2 (PDF 1 MB)
- TT_US_Cavity-New (PDF 522 KB)
- TT_US_Red-Rel (PDF 229 KB)
CAD files
Frequently asked questions
Is PRHRLAN the same as PRHR-LAN?
Yes. Sun Hydraulics writes this part number as PRHRLAN. It is the model PRHR followed by the configuration code; hyphens, slashes and spaces are only dividers, so PRHRLAN, PRHR-LAN, PRHR LAN all refer to the same product.
Do you supply PRHRLAN in the UAE, GCC and India?
Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including PRHRLAN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.
Can I get the datasheet and CAD files?
Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.
Direct acting or pilot operated - what do I use?
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
How big is a drop of hydraulic oil?
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
What are the tolerances on pressure settings for Sun's pressure control valves?
Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page.
Can I back flow through a reducing valve from port 1 to port 2?
Yes. A reducing or reducing/relieving valve is normally open. If the pressure in the secondary circuit is less than the setting, it will be open.
2 caveats: (1) If the valve is in the reducing mode and you suddenly reverse the flow, the valve will not have time to open and will shift into relieving mode or (2) If the back flow generates a pressure drop through the valve that exceeds the setting, the valve will shift into the relieving mode.
When in doubt, use a reverse flow check.
I need a reducer on B. Can I connect the drain to A?
Yes. If you look in the sandwich section you will see that we offer many such packages. When you are pressurizing B, A is connected to tank, allowing the reducer to do its job. When you reverse, the drain or tank port of the reducer is pressurized by A. This increases the setting of the reducer and helps keep the reducer open in the reverse flow direction.
What do you mean by maximum differential?
Our reducing valves are outside-in valves; the supply pressure on the outside of the working parts is higher than the inside. At some pressure differential, the outside (sleeve) will close in on the piston and cause the valve to stick. A D range is adjustable from 25 to 800 psi with a maximum differential of 2000 psi. This means you could set the valve at 600 psi and expect it to work correctly with a supply pressure of 2600 psi. The valve may work at higher differentials, but we do not recommend it. The W and C ranges are tested over their entire range with an inlet pressure of 5000 psi. All direct-acting valves are tested with an inlet pressure of 5000 psi.
What parts of the Sun cartridge valve are field serviceable?
Manufacturer reference: https://www.sunhydraulics.com/model/PRHR