FPCHXCN212 – Sun Hydraulics Electro-proportional flow control valve - normally open, DIN 43650-Form A, 12 VDC

Part number: FPCHXCN · FPCH-XCN · FPCH XCN

Brand Sun HydraulicsType Flow ControlCapacity 7 gpm (28 L/min.)Cavity T-13A

Electro-proportional flow control valve – normally open. Cavity T-13A, capacity 7 gpm (28 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: FPCH Category: Brand:

FPCH-XCN overview

FPCHXCN (FPCH-XCN, FPCH XCN) is a Sun Hydraulics Sun Hydraulics Electro-proportional flow control valve - normally open, rated 7 gpm (28 L/min.) and installed in cavity T-13A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

FPCHXCN No coilNo coil
FPCHXCN212 DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC
FPCHXCN212N DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodesDIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes
FPCHXCN212NX01 DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driverDIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver

Specifications

CavityT-13A
Series1
Capacity7 gpm (28 L/min.)
Maximum Valve Leakage at 110 SUS (24 cSt)6 in³/min.@3000 psi (100 cc/min.@210 bar)
Manual Override Force Requirement5 lbs/1000 psi @ Port 1 (33 N/100 bar @ Port 1)
Manual Override Stroke.10 in. (2,5 mm)
Solenoid Tube Diameter.75 in. (19 mm)
Valve Hex Size7/8 in. (22,2 mm)
Valve Installation Torque30 - 35 lbf ft (41 - 47 Nm)
Model Weight (with coil)1.10 lb (0,50 kg)
Seal kit - CartridgeViton: 990413006
Seal and nut kit - CoilViton: 990770006

Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.

How to read FPCHXCN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so FPCHXCN, FPCH-XCN, FPCH XCN are the same part.

ModelFPCH — Sun Hydraulics Electro-proportional flow control valve - normally open
ControlX — No Manual Override
Flow RateC — .25 - 7 gpm (1 - 28 L/min.)
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Control options
  • X — No Manual Override
  • D — Twist/Lock (Dual) Manual Override
  • E — Twist (Extended) Manual Override
  • L — Twist/Lock (Detent) Manual Override
  • M — Manual Override
  • T — Twist (Momentary) Manual Override
Flow Rate options
  • C — .25 - 7 gpm (1 - 28 L/min.)
  • A — .1 - 1.5 gpm (0,4 - 6 L/min.)
  • B — .15 - 3.5 gpm (0,6 - 14 L/min.)
Seal Material options
  • N — Buna-N
  • V — Viton
  • E — EPDM
Coil options
  • — No coil
  • 212 — DIN 43650-Form A, 12 VDC
  • 212N — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes
  • 212NX01 — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 212NX02 — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 214 — DIN 43650-Form A, 14 VDC
  • 214N — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes
  • 214NX01 — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 214NX02 — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 224 — DIN 43650-Form A, 24 VDC
  • 224N — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes
  • 224NX01 — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 224NX02 — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 2B12A — DIN 43650-Form A, command common on fourth pin, 12 VDC, 0-20 mA
  • 2B12B — DIN 43650-Form A, command common on fourth pin, 12 VDC, Bluetooth
  • 2B12V — DIN 43650-Form A, command common on fourth pin, 12 VDC, 0-10V
  • 2B24A — DIN 43650-Form A, command common on fourth pin, 24 VDC, 0-20 mA
  • 2B24B — DIN 43650-Form A, command common on fourth pin, 24 VDC, Bluetooth
  • 2B24V — DIN 43650-Form A, command common on fourth pin, 24 VDC, 0-10V
  • 2C12V — DIN 43650-Form A, +5V reference on fourth pin, 12 VDC, 0-10V
  • 2C24V — DIN 43650-Form A, +5V reference on fourth pin, 24 VDC, 0-10V
  • 2D12A — DIN 43650-Form A, enable input on fourth pin, 12 VDC, 0-20 mA
  • 2D24A — DIN 43650-Form A, enable input on fourth pin, 24 VDC, 0-20 mA
  • 2D24V — DIN 43650-Form A, enable input on fourth pin, 24 VDC, 0-10V
  • 2F12V — DIN 43650-Form A, programmable ramps, separate rise and fall, 12 VDC
  • 2F24V — DIN 43650-Form A, programmable ramps, separate rise and fall, 24 VDC
  • 4A12A — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, 0-20 mA
  • 4A12B — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, Bluetooth
  • 4A12V — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, 0-10V
  • 4A24A — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, 0-20 mA
  • 4A24B — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, Bluetooth
  • 4A24V — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, 0-10V
  • 4F12V — Deutsch DT04-6P, programmable ramps, separate rise and fall, 12 VDC
  • 4F24V — Deutsch DT04-6P, programmable ramps, separate rise and fall, 24 VDC
  • 812 — Metri-Pack, 12 VDC
  • 912 — Deutsch DT04-2P, 12 VDC
  • 912N — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes
  • 912NX01 — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 912NX02 — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 914NX01 — Deutsch DT04-2P, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 914NX02 — Deutsch DT04-2P, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 924 — Deutsch DT04-2P, 24 VDC
  • 924N — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes
  • 924NX01 — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 924NX02 — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • HN24AA — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 10 feet twin lead, ATEX Certification Ex mb IIC T3 Gb.
  • HN24AB — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 10 feet twin lead, CSA Certification

Manifold & standard assemblies

Sun manifolds for cavity T-13A (155)

View all 155 →

Technical features

  • Available in either a normally open or normally closed configuration with three different capacity ranges.
  • Capable of operating with pressures up to 5000 psi (350 bar).
  • Low leakage levels in the closed position.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • This cartridge has several manual override choices, including no manual override. See Option Configuration.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Drawings, symbol & performance curves

FPCH-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FPCH-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FPCH-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FPCH-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FPCH-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FPCH-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FPCH-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FPCH-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FPCH-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FPCH-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FPCHXCN Sun Hydraulics Flow Control Valve – 2D outline drawing
2D outline drawing

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is FPCHXCN the same as FPCH-XCN?

Yes. Sun Hydraulics writes this part number as FPCHXCN. It is the model FPCH followed by the configuration code; hyphens, slashes and spaces are only dividers, so FPCHXCN, FPCH-XCN, FPCH XCN all refer to the same product.

Do you supply FPCHXCN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including FPCHXCN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

What is the compensating pressure of Sun's flow controls?

The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.

How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

What is the pressure drop through a flow control?

In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.

How accurate are Sun's flow controls?

We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.

I have a heat problem, will Sun's priority flow control help?

I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.

What happens if I block the control flow (priority) port?

All flow is blocked, hence the term priority. The priority flow has to be satisfied.

What happens if I block the bypass port on a priority flow control?

The valve acts as a 2 port restrictive flow control.

What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.