FMDBXCN212 – Sun Hydraulics Electro-proportional 3-way flow control valve, meter in, DIN 43650-Form A, 12 VDC

Part number: FMDBXCN · FMDB-XCN · FMDB XCN

Brand Sun HydraulicsType Flow ControlCapacity 6 gpm (23 L/min.)Cavity T-11A

Electro-proportional 3-way flow control valve, meter in. Cavity T-11A, capacity 6 gpm (23 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: FMDB Category: Brand:

FMDB-XCN overview

FMDBXCN (FMDB-XCN, FMDB XCN) is a Sun Hydraulics Sun Hydraulics Electro-proportional 3-way flow control valve, meter in, rated 6 gpm (23 L/min.) and installed in cavity T-11A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

FMDBXCN No coilNo coil
FMDBXCN212 DIN 43650-Form A, 12 VDCDIN 43650-Form A, 12 VDC
FMDBXCN212N DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodesDIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes
FMDBXCN212NX01 DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driverDIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver

Specifications

CavityT-11A
Series1
Capacity6 gpm (23 L/min.)
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi (30 cc/min.@70 bar)
Manual Override Force Requirement5 lbs/1000 psi @ Port 1 (33 N/100 bar @ Port 1)
Manual Override Stroke.10 in. (2,5 mm)
Solenoid Tube Diameter.75 in. (19 mm)
Valve Hex Size7/8 in. (22,2 mm)
Valve Installation Torque30 - 35 lbf ft (41 - 47 Nm)
Model Weight (with coil)1.10 lb (0,50 kg)
Seal kit - CartridgeViton: 990411006
Seal and nut kit - CoilViton: 990770006

Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.

How to read FMDBXCN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so FMDBXCN, FMDB-XCN, FMDB XCN are the same part.

ModelFMDB — Sun Hydraulics Electro-proportional 3-way flow control valve, meter in
ControlX — No Manual Override
Flow RateC — .1 - 6 gpm (0,4 - 23 L/min.)
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Control options
  • D — Twist/Lock (Dual) Manual Override
  • E — Twist (Extended) Manual Override
  • L — Twist/Lock (Detent) Manual Override
  • M — Manual Override
  • T — Twist (Momentary) Manual Override
  • X — No Manual Override
Flow Rate options
  • A — .1 - 1.6 gpm (0,4 - 6.1 L/min.)
  • B — .1 - 4 gpm (0,4 - 15 L/min.)
  • C — .1 - 6 gpm (0,4 - 23 L/min.)
Seal Material options
  • N — Buna-N
  • V — Viton
Coil options
  • — No coil
  • 212 — DIN 43650-Form A, 12 VDC
  • 212N — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes
  • 212NX01 — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 212NX02 — DIN 43650-Form A, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 214N — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes
  • 214NX01 — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 214NX02 — DIN 43650-Form A, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 224 — DIN 43650-Form A, 24 VDC
  • 224N — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes
  • 224NX01 — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 224NX02 — DIN 43650-Form A, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 2B12A — DIN 43650-Form A, command common on fourth pin, 12 VDC, 0-20 mA
  • 2B12B — DIN 43650-Form A, command common on fourth pin, 12 VDC, Bluetooth
  • 2B12V — DIN 43650-Form A, command common on fourth pin, 12 VDC, 0-10V
  • 2B24A — DIN 43650-Form A, command common on fourth pin, 24 VDC, 0-20 mA
  • 2B24B — DIN 43650-Form A, command common on fourth pin, 24 VDC, Bluetooth
  • 2B24V — DIN 43650-Form A, command common on fourth pin, 24 VDC, 0-10V
  • 2C12V — DIN 43650-Form A, +5V reference on fourth pin, 12 VDC, 0-10V
  • 2C24V — DIN 43650-Form A, +5V reference on fourth pin, 24 VDC, 0-10V
  • 2D12A — DIN 43650-Form A, enable input on fourth pin, 12 VDC, 0-20 mA
  • 2D24A — DIN 43650-Form A, enable input on fourth pin, 24 VDC, 0-20 mA
  • 2D24V — DIN 43650-Form A, enable input on fourth pin, 24 VDC, 0-10V
  • 2F12V — DIN 43650-Form A, programmable ramps, separate rise and fall, 12 VDC
  • 2F24V — DIN 43650-Form A, programmable ramps, separate rise and fall, 24 VDC
  • 4A12A — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, 0-20 mA
  • 4A12B — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, Bluetooth
  • 4A12V — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 12 VDC, 0-10V
  • 4A24A — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, 0-20 mA
  • 4A24B — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, Bluetooth
  • 4A24V — Deutsch DT04-6P, all functions enabled (separate command common, 5 v reference, and an enable), 24 VDC, 0-10V
  • 4F12V — Deutsch DT04-6P, programmable ramps, separate rise and fall, 12 VDC
  • 4F24V — Deutsch DT04-6P, programmable ramps, separate rise and fall, 24 VDC
  • 812 — Metri-Pack, 12 VDC
  • 912 — Deutsch DT04-2P, 12 VDC
  • 912N — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes
  • 912NX01 — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 912NX02 — Deutsch DT04-2P, 12 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 914 — Deutsch DT04-2P, 14 VDC
  • 914N — Deutsch DT04-2P, 14 VDC, no transient voltage suppression (TVS) diodes
  • 914NX01 — Deutsch DT04-2P, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 914NX02 — Deutsch DT04-2P, 14 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • 924 — Deutsch DT04-2P, 24 VDC
  • 924N — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes
  • 924NX01 — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-01 driver
  • 924NX02 — Deutsch DT04-2P, 24 VDC, no transient voltage suppression (TVS) diodes, with XMD-02 driver
  • HN24AA — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 10 feet twin lead, ATEX Certification Ex mb IIC T3 Gb.
  • HN24AB — Explosion Proof, 1/2 inch NPT mechanical conduit, 24 VDC, 10 feet twin lead, CSA Certification

Manifold & standard assemblies

Sun manifolds for cavity T-11A (583)

View all 583 →

Technical features

  • The transition between positions is closed.
  • Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
  • These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
  • The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
  • All ports will accept 5000 psi (350 bar).
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Drawings, symbol & performance curves

FMDB-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDB-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDB-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDB-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDB-XCN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FMDB-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDB-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDB-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDB-XCN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FMDBXCN Sun Hydraulics Flow Control Valve – 2D outline drawing
2D outline drawing

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is FMDBXCN the same as FMDB-XCN?

Yes. Sun Hydraulics writes this part number as FMDBXCN. It is the model FMDB followed by the configuration code; hyphens, slashes and spaces are only dividers, so FMDBXCN, FMDB-XCN, FMDB XCN all refer to the same product.

Do you supply FMDBXCN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including FMDBXCN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

What happens if I block the bypass port on a priority flow control?

The valve acts as a 2 port restrictive flow control.

What is the compensating pressure of Sun's flow controls?

The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.

How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

What is the pressure drop through a flow control?

In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.

How accurate are Sun's flow controls?

We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.

I have a heat problem, will Sun's priority flow control help?

I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.

What happens if I block the control flow (priority) port?

All flow is blocked, hence the term priority. The priority flow has to be satisfied.

What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

Manufacturer reference: https://www.sunhydraulics.com/model/FMDB

See It Styled On Instagram

    No access token

Main Menu