Product Price Quantity Total  
RDFA3-AN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RDFA3-AN – Sun Hydraulics Non-adjustable direct-acting relief valve - N – Buna-N
Assembly:

RDFA3AN-VLZ/Y5

VLZ Sun Hydraulics 3 Station, Parallel circuit with relief cavity Bar manifold manifold drawing VLZ – Sun Hydraulics 3 Station, Parallel circuit with relief cavity Bar manifold manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

RDFA3AN-VLZ/Y5

CAEA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEALHN-WKR/Y5

WKR Sun Hydraulics Danfoss OMT: Cross pilot on B with shuttle Motor mount manifold drawing WKR – Sun Hydraulics Danfoss OMT: Cross pilot on B with shuttle Motor mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CAEALHN-WKR/Y5

XDCA-XXN Sun Hydraulics Cavity Plug Valve – hydraulic schematic symbol XDCA-XXN – Sun Hydraulics All ports blocked cavity plug - /LH – Mild Steel, Zinc-Nickel
Assembly:

XDCAXXN/LH-DAA

DAA Sun Hydraulics Ninety degree Line mount manifold drawing DAA – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

XDCAXXN/LH-DAA

CBGB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGB-LHN – Sun Hydraulics 1.5:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGBLHN-XC4/Y5

XC4 Sun Hydraulics Cross port with shuttle on port 3s Line mount manifold drawing XC4 – Sun Hydraulics Cross port with shuttle on port 3s Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CBGBLHN-XC4/Y5

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-WKN/Y4

WKN Sun Hydraulics Danfoss OMT: Cross pilot on A with shuttle Motor mount manifold drawing WKN – Sun Hydraulics Danfoss OMT: Cross pilot on A with shuttle Motor mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBDDXXN-WKN/Y4

VGW Sun Hydraulics Ninety degree Line mount manifold drawing VGW – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DNCAZXN224-VGW

CAEA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEALHN-ZLV/Y5

ZLV Sun Hydraulics Direct mount Line mount manifold drawing ZLV – Sun Hydraulics Direct mount Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CAEALHN-ZLV/Y5

CXFHZ-CN Sun Hydraulics Position Indication Valve – installation dimensions drawing, cavity T-5A CXFHZ-CN – Sun Hydraulics Free flow nose to side check valve with position switch - N – Buna-N
Assembly:

CXFHZCN-DND/Y

DND Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing DND – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CXFHZCN-DND/Y

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-BBI/Y5

BBI Sun Hydraulics ISO 05: On A or B, port 3 to T Sandwich manifold drawing BBI – Sun Hydraulics ISO 05: On A or B, port 3 to T Sandwich manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CBDDXXN-BBI/Y5

CAEA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEALHN-WKR/Y

WKR Sun Hydraulics Danfoss OMT: Cross pilot on B with shuttle Motor mount manifold drawing WKR – Sun Hydraulics Danfoss OMT: Cross pilot on B with shuttle Motor mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CAEALHN-WKR/Y

CBIY-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIY-LHN – Sun Hydraulics 2:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBIYLHN-ZNY/Y

ZNY Sun Hydraulics Direct mount Line mount manifold drawing ZNY – Sun Hydraulics Direct mount Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CBIYLHN-ZNY/Y

CXID-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-18A CXID-XCN – Sun Hydraulics Free flow side to nose check valve - Standard Material/Coating
Assembly:

CXIDXCN-U4E/Y3

U4E Sun Hydraulics Sandwich mount through port Line mount manifold drawing U4E – Sun Hydraulics Sandwich mount through port Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CXIDXCN-U4E/Y3

CNJC-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-18A CNJC-XCN – Sun Hydraulics Free flow nose to side check valve with bypass orifice - Standard Material/Coating
Assembly:

CNJCXCN-ZEG/T

ZEG Sun Hydraulics Direct mount Line mount manifold drawing ZEG – Sun Hydraulics Direct mount Line mount manifold - /T – 65-45-12 Ductile Iron, Metric, Buna-N, Dewatering Oil
Assembly:

CNJCXCN-ZEG/T

DFFJ-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFJ-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series) - No coil
Assembly:

DFFJXCN-U4E/Y3

U4E Sun Hydraulics Sandwich mount through port Line mount manifold drawing U4E – Sun Hydraulics Sandwich mount through port Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

DFFJXCN-U4E/Y3

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-B4C/Y3

B4C Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing B4C – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDDXXN-B4C/Y3

COBA-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-163A COBA-XCN – Sun Hydraulics Pilot-to-close check valve - Standard Material/Coating
Assembly:

COBAXCN-J2B/Y4

J2B Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing J2B – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

COBAXCN-J2B/Y4

Back To Shop

Cart totals

Subtotal
Total

Main Menu