Subtotal:
DPCA-LAN – Sun Hydraulics 2-way, pilot-operated, directional valve with internal drain to port 3 – normally open
Part number: DPCALAN · DPCA-LAN · DPCA LAN
2-way, pilot-operated, directional valve with internal drain to port 3 – normally open. Cavity T-2A, capacity 15 gpm (60 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.
DPCA-LAN overview
DPCALAN (DPCA-LAN, DPCA LAN) is a Sun Hydraulics Sun Hydraulics 2-way, pilot-operated, directional valve with internal drain to port 3 - normally open, rated 15 gpm (60 L/min.) and installed in cavity T-2A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.
Specifications
| Cavity | T-2A |
|---|---|
| Series | 2 |
| Capacity | 15 gpm (60 L/min.) |
| Maximum Operating Pressure | 5000 psi (350 bar) |
| Factory Pressure Settings Established at | 4 gpm (15 L/min.) |
| Control Pilot Flow | 10 - 15 in³/min. (0,16 - 0,25 L/min.) |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 1 in³/min.@1000 psi (15 cc/min.@70 bar) |
| Adjustment - No. of CW Turns from Min. to Max. setting | 5 |
| Valve Hex Size | 1 1/8 in. (28,6 mm) |
| Valve Installation Torque | 45 - 50 lbf ft (61 - 68 Nm) |
| Adjustment Screw Internal Hex Size | 5/32 in. (4 mm) |
| Locknut Hex Size | 9/16 in. (15 mm) |
| Locknut Torque | 80 - 90 lbf in. (9 - 10 Nm) |
| Model Weight | .60 lb (0,30 kg) |
| Seal kit - Cartridge | Viton: 990202006 |
For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
How to read DPCALAN
Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so DPCALAN, DPCA-LAN, DPCA LAN are the same part.
| Model | DPCA — Sun Hydraulics 2-way, pilot-operated, directional valve with internal drain to port 3 - normally open |
|---|---|
| Control | L — Standard Screw Adjustment |
| Adjustment Range | A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting |
| Seal Material | N — Buna-N |
| Material / coating | Add /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish. |
Control options
- C — Tamper Resistant - Factory Set
- K — Handknob
- L — Standard Screw Adjustment
- O — Handknob with Panel Mount
Adjustment Range options
- A — 100 - 3000 psi (7 - 210 bar), 1000 psi (70 bar) Standard Setting
- B — 50 - 1500 psi (3,5 - 105 bar), 1000 psi (70 bar) Standard Setting
- C — 150 - 6000 psi (10,5 - 420 bar), 3000 psi (210 bar) Standard Setting
- D — 25 - 800 psi (1,7 - 55 bar), 400 psi (28 bar) Standard Setting
- E — 25 - 400 psi (1,7 - 28 bar), 200 psi (14 bar) Standard Setting
- W — 100 - 4500 psi (7 - 315 bar), 1000 psi (70 bar) Standard Setting
Seal Material options
- N — Buna-N
- V — Viton
Material/coating options
- — Standard Material/Coating
Manifold & standard assemblies
Sun manifolds for cavity T-2A (544)
- 3BC Sun Hydraulics Cushion lock with shuttle Line mount manifoldDPCALAN-3BC — request assembly
- 3BD Sun Hydraulics Cushion lock with shuttle Line mount manifoldDPCALAN-3BD — request assembly
- 3BK Sun Hydraulics Cushion lock with shuttle Line mount manifoldDPCALAN-3BK — request assembly
- 3BL Sun Hydraulics Cushion lock with shuttle Line mount manifoldDPCALAN-3BL — request assembly
- 3BV Sun Hydraulics Cushion lock with shuttle Line mount manifoldDPCALAN-3BV — request assembly
- 3BW Sun Hydraulics Cushion lock with shuttle Line mount manifoldDPCALAN-3BW — request assembly
- 4BC Sun Hydraulics Cushion lock with make up checks Line mount manifoldDPCALAN-4BC — request assembly
- 4BD Sun Hydraulics Cushion lock with make up checks Line mount manifoldDPCALAN-4BD — request assembly
- 4BK Sun Hydraulics Cushion lock with make up checks Line mount manifoldDPCALAN-4BK — request assembly
- 4BL Sun Hydraulics Cushion lock with make up checks Line mount manifoldDPCALAN-4BL — request assembly
- 4BV Sun Hydraulics Cushion lock with make up checks Line mount manifoldDPCALAN-4BV — request assembly
- 4BW Sun Hydraulics Cushion lock with make up checks Line mount manifoldDPCALAN-4BW — request assembly
Technical features
- Pressure at port 3 is directly additive to the setting of the valve. Because of this, port 3 may not be useable as a work port in your circuit. If this is a consideration, the 4 port version of this valve may be a solution.
- Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
- This valve is not bistable; it is capable of modulating between the two positions shown.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
- When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve setting. If this is a problem, the direct acting version of this valve would be a solution.
- Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Drawings, symbol & performance curves
Downloads
Datasheet
Technical reference sheets
- 999-901-334 (PDF 344 KB)
- FloatingStyleScrewInCartridge2 (PDF 1 MB)
- TT_US_Cavity-New (PDF 522 KB)
- TT_US_PCDirectional-New_1 (PDF 630 KB)
CAD files
Frequently asked questions
Is DPCALAN the same as DPCA-LAN?
Yes. Sun Hydraulics writes this part number as DPCALAN. It is the model DPCA followed by the configuration code; hyphens, slashes and spaces are only dividers, so DPCALAN, DPCA-LAN, DPCA LAN all refer to the same product.
Do you supply DPCALAN in the UAE, GCC and India?
Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including DPCALAN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.
Can I get the datasheet and CAD files?
Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.
How big is a drop of hydraulic oil?
There are exactly 250 Sun drops in a cubic inch or 15 in a cc.
Direct acting or pilot operated - what do I use?
Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust.
What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable. Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.
I used a DP** in a circuit but it hangs. What happened?
DP**s and DR**s are from the reducer/reliever family and are very capable of modulating. They are not bistable.
Where would I use a DR__ instead of a DP__?
In many circuits the directional cartridge is set to shift at a low pressure no matter how high the pilot pressure goes. If you use a DP__ , the pilot flow increases to significant amounts. A DR__ however will only consume a small amount of flow. A DP__ is useful when you want to block or open the pilot flow to shift the valve.
Manufacturer reference: https://www.sunhydraulics.com/model/DPCA