QMEH4-GN – Sun Hydraulics Cartridge-style flow meter flow control valve

Part number: QMEH4GN · QMEH4-GN · QMEH4 GN

Brand Sun HydraulicsType Flow ControlCapacity 50 gpm (200 L/min.)Cavity T-16A

Cartridge-style flow meter flow control valve. Cavity T-16A, capacity 50 gpm (200 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: QMEH4 Category: Brand:

QMEH4-GN overview

QMEH4GN (QMEH4-GN, QMEH4 GN) is a Sun Hydraulics Sun Hydraulics Cartridge-style flow meter flow control valve, rated 50 gpm (200 L/min.) and installed in cavity T-16A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

QMEH4GN Buna-N sealsBuna-N
QMEH4GV Viton sealsViton

Specifications

CavityT-16A
Series3
Capacity50 gpm (200 L/min.)
Maximum Operating Pressure5000 psi (350 bar)
Supply Voltage6 - 32 VDC
Operating Temperature Range-13 - 176 °F
Storage Temperature Range-67 - 185 °F
Vibration6.8g Peak, 33.3 Hz
Shock49g Peak (Spec: S-367 Section 12.0) (49g Peak (Spec: S-367 Section 12.0))
TerminationM12X1 4-Pin
Output Signal4 - 20 mA or 0.5 - 4.5 V
Response Time - Maximum (Step input from 0-100%)500 ms
Accuracy≤ ± 10% Error of Full Scale (FS) (≤ ± 10% Error of Full Scale (FS))
Repeatability0.6% Full Scale (FS) (0.6% Full Scale (FS))
Reverse Polarity ProtectionYes
EMCIEC 61000-6-4:2018, IEC 61000-6-2:2016
Valve Hex Size1 1/4 in. (31,8 mm)
Valve Installation Torque150 - 160 lbf ft (203 - 217 Nm)
Model Weight.62 lb
IP RatingIP69K
CertificationCE, E-Mark, E24 10R-067705

How to read QMEH4GN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so QMEH4GN, QMEH4-GN, QMEH4 GN are the same part.

ModelQMEH4 — Sun Hydraulics Cartridge-style flow meter flow control valve
Flow RateG — 4 gpm 0.5-4.5 V (15 L/min.)
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Flow Rate options
  • A — 4 gpm 4-20 mA (15 L/min.)
  • B — 8 gpm 4-20 mA (30 L/min.)
  • E — 35 gpm 4-20 mA (140 L/min.)
  • F — 50 gpm 4-20 mA (200 L/min.)
  • G — 4 gpm 0.5-4.5 V (15 L/min.)
  • H — 8 gpm 0.5-4.5 V (30 L/min.)
  • L — 35 gpm 0.5-4.5 V (140 L/min.)
  • M — 50 gpm 0.5-4.5 V (200 L/min.)
Seal Material options
  • N — Buna-N
  • V — Viton

Manifold & standard assemblies

Sun manifolds for cavity T-16A (161)

View all 161 →

Technical features

  • Performance was validated using a fluid having a viscosity of 24 cSt. As the viscosity increases past 50 cSt, the maximum capacity begins to decrease. When it reaches 200 cSt a 12.5% decrease in capacity was observed. Flow at fluid viscosities higher than 200 cSt cannot be reliably measured with this flow meter.
  • All ports are rated to 5000 PSI maximum operating pressure. The valve is insensitive to backpressure up to the rated pressure.
  • Rated at IP69K (with IP69K rated mating connector).
  • Position sensor (US Patent # 12,484,150) is CE and E-Mark approved.
  • The performance of the 50 GPM and 35 GPM versions is sensitive to the size of the port hit diameter at Port 2. Optimal performance is achieved with a port hit diameter larger than 1 inch. Some recommended three-letter bodies are model code IA* with a port size designation larger than 1 inch (SAE 16).
  • When powered and there is no flow, the resting output of the sensor is 0.5V/4mA and increases to 4.5V/20mA as the flow increases, up to the upper limit of the flow range. Flow rates above the upper limit of the flow range will not cause the signal output to go higher than 4.5v/20mA . Therefore, flows higher than the published range cannot be measured and will output the maximum of either 4.5v/20mA.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Drawings, symbol & performance curves

QMEH4-GN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
QMEH4-GN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
QMEH4-GN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
QMEH4-GN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
QMEH4-GN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
QMEH4-GN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
QMEH4-GN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
QMEH4-GN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
QMEH4-GN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is QMEH4GN the same as QMEH4-GN?

Yes. Sun Hydraulics writes this part number as QMEH4GN. It is the model QMEH4 followed by the configuration code; hyphens, slashes and spaces are only dividers, so QMEH4GN, QMEH4-GN, QMEH4 GN all refer to the same product.

Do you supply QMEH4GN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including QMEH4GN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

What happens if I overflow the sensor past the upper end of the range?
Overflowing the sensor is unlikely to cause damage. However, the output signal is saturated at the bounds which means you will be unable to rely on sensor output to inform if an overflow condition has occurred.
I'm using a port hit diameter smaller than 1 inch on a 35 gpm/50 gpm range. What should I expect?
If the port hit diameter is smaller than 1 inch, somewhat counter intuitively, the capacity increases. Instead of 50 gpm, the capacity increases to 55 gpm and instead of 35 gpm, the capacity increases to 37 gpm range. The error tolerance is then applied from the new nominal. The increase in capacity is because the local backpressure caused by the port actually reduces the stroke of the piston.
Can the sensor be calibrated under the conditions specific to my application?
It may be possible to configure the sensor output under specific customer conditions depending on the application requirements. Please submit a request through our NPI portal if you have a need for custom flow ranges or other specific operating conditions.

Manufacturer reference: https://www.sunhydraulics.com/model/QMEH4