QMEH4-GN – Sun Hydraulics Cartridge-style flow meter flow control valve
Part number: QMEH4GN · QMEH4-GN · QMEH4 GN
Cartridge-style flow meter flow control valve. Cavity T-16A, capacity 50 gpm (200 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.
QMEH4-GN overview
QMEH4GN (QMEH4-GN, QMEH4 GN) is a Sun Hydraulics Sun Hydraulics Cartridge-style flow meter flow control valve, rated 50 gpm (200 L/min.) and installed in cavity T-16A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.
Ordering codes
Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.
| QMEH4GN | Buna-N sealsBuna-N |
|---|---|
| QMEH4GV | Viton sealsViton |
Specifications
| Cavity | T-16A |
|---|---|
| Series | 3 |
| Capacity | 50 gpm (200 L/min.) |
| Maximum Operating Pressure | 5000 psi (350 bar) |
| Supply Voltage | 6 - 32 VDC |
| Operating Temperature Range | -13 - 176 °F |
| Storage Temperature Range | -67 - 185 °F |
| Vibration | 6.8g Peak, 33.3 Hz |
| Shock | 49g Peak (Spec: S-367 Section 12.0) (49g Peak (Spec: S-367 Section 12.0)) |
| Termination | M12X1 4-Pin |
| Output Signal | 4 - 20 mA or 0.5 - 4.5 V |
| Response Time - Maximum (Step input from 0-100%) | 500 ms |
| Accuracy | ≤ ± 10% Error of Full Scale (FS) (≤ ± 10% Error of Full Scale (FS)) |
| Repeatability | 0.6% Full Scale (FS) (0.6% Full Scale (FS)) |
| Reverse Polarity Protection | Yes |
| EMC | IEC 61000-6-4:2018, IEC 61000-6-2:2016 |
| Valve Hex Size | 1 1/4 in. (31,8 mm) |
| Valve Installation Torque | 150 - 160 lbf ft (203 - 217 Nm) |
| Model Weight | .62 lb |
| IP Rating | IP69K |
| Certification | CE, E-Mark, E24 10R-067705 |
How to read QMEH4GN
Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so QMEH4GN, QMEH4-GN, QMEH4 GN are the same part.
| Model | QMEH4 — Sun Hydraulics Cartridge-style flow meter flow control valve |
|---|---|
| Flow Rate | G — 4 gpm 0.5-4.5 V (15 L/min.) |
| Seal Material | N — Buna-N |
| Material / coating | Add /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish. |
Flow Rate options
- A — 4 gpm 4-20 mA (15 L/min.)
- B — 8 gpm 4-20 mA (30 L/min.)
- E — 35 gpm 4-20 mA (140 L/min.)
- F — 50 gpm 4-20 mA (200 L/min.)
- G — 4 gpm 0.5-4.5 V (15 L/min.)
- H — 8 gpm 0.5-4.5 V (30 L/min.)
- L — 35 gpm 0.5-4.5 V (140 L/min.)
- M — 50 gpm 0.5-4.5 V (200 L/min.)
Seal Material options
- N — Buna-N
- V — Viton
Manifold & standard assemblies
Sun manifolds for cavity T-16A (161)
- CD4 Sun Hydraulics ISO 08: On A with reverse flow check Sandwich manifoldQMEH4GN-CD4 — request assembly
- CDC Sun Hydraulics ISO 08: A to T Sandwich manifoldQMEH4GN-CDC — request assembly
- CDD Sun Hydraulics ISO 08: B to T Sandwich manifoldQMEH4GN-CDD — request assembly
- CDO Sun Hydraulics ISO 08: P to T Sandwich manifoldQMEH4GN-CDO — request assembly
- CDV Sun Hydraulics ISO 08: T to A and B Sandwich manifoldQMEH4GN-CDV — request assembly
- CDW Sun Hydraulics ISO 08: A to B and B to A Sandwich manifoldQMEH4GN-CDW — request assembly
- CDZ Sun Hydraulics ISO 08: A and B to T Sandwich manifoldQMEH4GN-CDZ — request assembly
- CK4 Sun Hydraulics ISO 07: On A with reverse flow check Sandwich manifoldQMEH4GN-CK4 — request assembly
- CKD Sun Hydraulics ISO 07: A to T with gage port Sandwich manifoldQMEH4GN-CKD — request assembly
- IA4 Sun Hydraulics Ninety degree with gauge port Line mount manifoldQMEH4GN-IA4 — request assembly
- IA5 Sun Hydraulics Ninety degree with gauge port Line mount manifoldQMEH4GN-IA5 — request assembly
- IA6 Sun Hydraulics Ninety degree with gauge port Line mount manifoldQMEH4GN-IA6 — request assembly
Technical features
- Performance was validated using a fluid having a viscosity of 24 cSt. As the viscosity increases past 50 cSt, the maximum capacity begins to decrease. When it reaches 200 cSt a 12.5% decrease in capacity was observed. Flow at fluid viscosities higher than 200 cSt cannot be reliably measured with this flow meter.
- All ports are rated to 5000 PSI maximum operating pressure. The valve is insensitive to backpressure up to the rated pressure.
- Rated at IP69K (with IP69K rated mating connector).
- Position sensor (US Patent # 12,484,150) is CE and E-Mark approved.
- The performance of the 50 GPM and 35 GPM versions is sensitive to the size of the port hit diameter at Port 2. Optimal performance is achieved with a port hit diameter larger than 1 inch. Some recommended three-letter bodies are model code IA* with a port size designation larger than 1 inch (SAE 16).
- When powered and there is no flow, the resting output of the sensor is 0.5V/4mA and increases to 4.5V/20mA as the flow increases, up to the upper limit of the flow range. Flow rates above the upper limit of the flow range will not cause the signal output to go higher than 4.5v/20mA . Therefore, flows higher than the published range cannot be measured and will output the maximum of either 4.5v/20mA.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Drawings, symbol & performance curves
Downloads
Datasheet
Technical reference sheets
CAD files
Frequently asked questions
Is QMEH4GN the same as QMEH4-GN?
Yes. Sun Hydraulics writes this part number as QMEH4GN. It is the model QMEH4 followed by the configuration code; hyphens, slashes and spaces are only dividers, so QMEH4GN, QMEH4-GN, QMEH4 GN all refer to the same product.
Do you supply QMEH4GN in the UAE, GCC and India?
Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including QMEH4GN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.
Can I get the datasheet and CAD files?
Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.
What happens if I overflow the sensor past the upper end of the range?
I'm using a port hit diameter smaller than 1 inch on a 35 gpm/50 gpm range. What should I expect?
Can the sensor be calibrated under the conditions specific to my application?
Manufacturer reference: https://www.sunhydraulics.com/model/QMEH4