FVCA-XAN – Sun Hydraulics Ventable, fixed-orifice, bypass/restrictive, priority flow control valve

Part number: FVCAXAN · FVCA-XAN · FVCA XAN

Brand Sun HydraulicsType Flow ControlCapacity 6 gpm (23 L/min.)Cavity T-21A

Ventable, fixed-orifice, bypass/restrictive, priority flow control valve. Cavity T-21A, capacity 6 gpm (23 L/min.). Genuine Sun Hydraulics cartridge — MultiFlow is an authorized distributor.

Clear
SKU: FVCA Category: Brand:

FVCA-XAN overview

FVCAXAN (FVCA-XAN, FVCA XAN) is a Sun Hydraulics Sun Hydraulics Ventable, fixed-orifice, bypass/restrictive, priority flow control valve, rated 6 gpm (23 L/min.) and installed in cavity T-21A. MultiFlow supplies genuine Sun Hydraulics cartridges in the UAE, GCC and India — use Add to Enquiry above for availability and a quotation.

Ordering codes

Pick the code that matches the material and finish you need. Add it to your enquiry above, or tap a code to select it.

FVCAXAN Buna-N sealsBuna-N
FVCAXAV Viton sealsViton

Specifications

CavityT-21A
Series1
Capacity6 gpm (23 L/min.)
Maximum Operating Pressure5000 psi (350 bar)
Nominal Vent Flow46 in³/min. (0,75 L/min.)
Maximum Input Flow15 gpm (60 L/min.)
Valve Hex Size7/8 in. (22,2 mm)
Valve Installation Torque30 - 35 lbf ft (41 - 47 Nm)
Adjustment Screw Internal Hex Size5/32 in. (4 mm)
Locknut Hex Size9/16 in. (15 mm)
Locknut Torque80 - 90 lbf in. (9 - 10 Nm)
Model Weight.30 lb (0,15 kg)
Seal kit - CartridgeViton: 990021006

How to read FVCAXAN

Sun part numbers are the model followed by one code per option. Hyphens, slashes and spaces are only dividers, so FVCAXAN, FVCA-XAN, FVCA XAN are the same part.

ModelFVCA — Sun Hydraulics Ventable, fixed-orifice, bypass/restrictive, priority flow control valve
ControlX — Not Adjustable
Setting RangeA — Replaceable Orifice .1 - 6 gpm (0,4 - 23 L/min.)
Seal MaterialN — Buna-N
Material / coatingAdd /AP (stainless steel, passivated) or /LH (mild steel, zinc-nickel) to the end; no suffix is the standard finish.
Control options
  • L — Tuning Adjustment
  • X — Not Adjustable
Setting Range options
  • A — Replaceable Orifice .1 - 6 gpm (0,4 - 23 L/min.)
  • B — Permanent Orifice .1 - 6 gpm (0,4 - 23 L/min.)
Seal Material options
  • N — Buna-N
  • V — Viton

Manifold & standard assemblies

Sun manifolds for cavity T-21A (54)

View all 54 →

Technical features

  • Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting.
  • Using a pressure control on port 4 will limit the pressure at the priority port (port 3). If pressure on the bypass port (port 2) exceeds the setting of the pressure control, priority flow will be shut off and all the flow will go out the bypass port.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Both priority and bypass flow are usable up to the system operating pressure.
  • Priority remains relatively constant regardless of variation in input flow.
  • Bypass flow is not available until priority flow requirements are satisfied, except when the valve is vented. When port 4 (vent) is open, all flow diverts to port 2 if pressure at port 1 (inlet) is 150 psi (10,5 bar) or higher.
  • Pressure at the bypass port (port 2) may exceed pressure at the priority port (port 3).
  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Drawings, symbol & performance curves

FVCA-XAN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FVCA-XAN Sun Hydraulics Flow Control Valve – hydraulic schematic symbol
hydraulic schematic symbol
FVCA-XAN Sun Hydraulics Flow Control Valve – performance curve (pressure drop vs flow)
performance curve (pressure drop vs flow)
FVCAXAN Sun Hydraulics Flow Control Valve – 2D outline drawing
2D outline drawing

Downloads

Datasheet

Technical reference sheets

CAD files

Frequently asked questions

Is FVCAXAN the same as FVCA-XAN?

Yes. Sun Hydraulics writes this part number as FVCAXAN. It is the model FVCA followed by the configuration code; hyphens, slashes and spaces are only dividers, so FVCAXAN, FVCA-XAN, FVCA XAN all refer to the same product.

Do you supply FVCAXAN in the UAE, GCC and India?

Yes. MultiFlow supplies genuine Sun Hydraulics cartridges, including FVCAXAN, to customers in the UAE, the wider GCC and India. Use Add to Enquiry on this page for availability, lead time and a quotation.

Can I get the datasheet and CAD files?

Yes. The datasheet, technical reference sheets and CAD files (DXF, DWG, STP) are listed in the Downloads section of this page.

What is the pressure drop through a flow control?

In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi.

How accurate are Sun's flow controls?

We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy.

I have a heat problem, will Sun's priority flow control help?

I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat.

What happens if I block the control flow (priority) port?

All flow is blocked, hence the term priority. The priority flow has to be satisfied.

What happens if I block the bypass port on a priority flow control?

The valve acts as a 2 port restrictive flow control.

What is the compensating pressure of Sun's flow controls?

The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating.

How big is a drop of hydraulic oil?  

There are exactly 250 Sun drops in a cubic inch or 15 in a cc.

What parts of the Sun cartridge valve are field serviceable?
Only external seals are serviceable.  Sun offers replacement seal kits for all cartridge models. The applicable kit part number can be found in the product page's Technical Data table or by using our Cartridge Seal Kit search function located under Accessories. Please note: Converting the external seals from one material to another does not ensure fluid compatibility with that material due to the existence of internal seals within the cartridge.

Manufacturer reference: https://www.sunhydraulics.com/model/FVCA