Product Price Quantity Total  
LRJA-XHN Sun Hydraulics Modulating Spool Valve – installation dimensions drawing, cavity T-19A LRJA-XHN – Sun Hydraulics Normally closed, modulating element with pilot source from port 1 - Standard Material/Coating
Assembly:

LRJAXHN-K2D

K2D Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2D – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LRJAXHN-K2D

LPBA-XHN Sun Hydraulics Modulating Spool Valve – installation dimensions drawing, cavity T-163A LPBA-XHN – Sun Hydraulics Normally open, modulating element with pilot source from port 1 - V – Viton
Assembly:

LPBAXHV-J6B

J6B Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing J6B – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LPBAXHV-J6B

LRJA-XHN Sun Hydraulics Modulating Spool Valve – installation dimensions drawing, cavity T-19A LRJA-XHN – Sun Hydraulics Normally closed, modulating element with pilot source from port 1 - Standard Material/Coating
Assembly:

LRJAXHN-K2M

K2M Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2M – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LRJAXHN-K2M

DRAY-LAN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-21A DRAY-LAN – Sun Hydraulics 2-way, pilot-to-shift directional valve with drain to port 4 - normally open - Standard Material/Coating
Assembly:

DRAYLAN-M4V

M4V Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4V – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DRAYLAN-M4V

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-BKB/S

BKB Sun Hydraulics ISO 07: On B, port 3 to A Sandwich manifold drawing BKB – Sun Hydraulics ISO 07: On B, port 3 to A Sandwich manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CBFLLJN-BKB/S

RDDA3-AN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RDDA3-AN – Sun Hydraulics Non-adjustable direct-acting relief valve - Standard Material/Coating
Assembly:

RDDA3AN-FGI

FGI Sun Hydraulics Through port Line mount manifold drawing FGI – Sun Hydraulics Through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RDDA3AN-FGI

RDFA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RDFA-LAN – Sun Hydraulics Direct-acting relief valve - Standard Material/Coating
Assembly:

RDFALAN-CKA/S3

CKA Sun Hydraulics ISO 07: A to T with gage port Sandwich manifold drawing CKA – Sun Hydraulics ISO 07: A to T with gage port Sandwich manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RDFALAN-CKA/S3

DFDB8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-5A DFDB8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 2-1 - N – Buna-N
Assembly:

DFDB8DN-WBW/S3

WBW Sun Hydraulics Sandwich mount through port Line mount manifold drawing WBW – Sun Hydraulics Sandwich mount through port Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DFDB8DN-WBW/S3

RBFA-LWN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBFA-LWN – Sun Hydraulics Bi-directional direct-acting relief valve - N – Buna-N
Assembly:

RBFALWN-CBP/S4

CBP Sun Hydraulics ISO 05: P to T Sandwich manifold drawing CBP – Sun Hydraulics ISO 05: P to T Sandwich manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

RBFALWN-CBP/S4

CACL-LFN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACL-LFN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACLLFN-U6U/S3

U6U Sun Hydraulics Throttle, high capacity with bypass Line mount manifold drawing U6U – Sun Hydraulics Throttle, high capacity with bypass Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CACLLFN-U6U/S3

CACL-LFN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACL-LFN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACLLFN-Z3H/S

Z3H Sun Hydraulics Direct mount Line mount manifold drawing Z3H – Sun Hydraulics Direct mount Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CACLLFN-Z3H/S

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-BLL

BLL Sun Hydraulics Ninety degree with high capacity port 3 and gauge port Line mount manifold drawing BLL – Sun Hydraulics Ninety degree with high capacity port 3 and gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCXNN-BLL

Back To Shop

Cart totals

Subtotal
Total

Main Menu