Product Price Quantity Total  
CXTA-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity SC-08-02 CXTA-XCN – Sun Hydraulics Free flow nose to side check valve - common cavity - N – Buna-N
Assembly:

CXTAXCN-JQA

JQA Sun Hydraulics Ninety degree Line mount manifold drawing JQA – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXTAXCN-JQA

CWCH-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-21A CWCH-LGN – Sun Hydraulics 10:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWCHLGN-Z3X/Y4

Z3X Sun Hydraulics Direct mount Line mount manifold drawing Z3X – Sun Hydraulics Direct mount Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CWCHLGN-Z3X/Y4

RDDA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RDDA-LAN – Sun Hydraulics Direct-acting relief valve - Standard Material/Coating
Assembly:

RDDALAN-FMU/Y5

FMU Sun Hydraulics Cross port with make up checks Line mount manifold drawing FMU – Sun Hydraulics Cross port with make up checks Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

RDDALAN-FMU/Y5

CVGV-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-23A CVGV-XCN – Sun Hydraulics Vented pilot-to-open check valve - Standard Material/Coating
Assembly:

CVGVXCN-P45/W3

P45 Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing P45 – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /W3 – 65-45-12 Ductile Iron, Metric, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CVGVXCN-P45/W3

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-X4C/Y1

X4C Sun Hydraulics Through port 3 Line mount manifold drawing X4C – Sun Hydraulics Through port 3 Line mount manifold - /Y1 – 65-45-12 Ductile Iron, Viton, Clear Zinc Nickel with Top Sealer
Assembly:

CACALHN-X4C/Y1

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-ZYB/Y1

ZYB Sun Hydraulics Direct mount Line mount manifold drawing ZYB – Sun Hydraulics Direct mount Line mount manifold - /Y1 – 65-45-12 Ductile Iron, Viton, Clear Zinc Nickel with Top Sealer
Assembly:

CACKLHN-ZYB/Y1

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-U9G/Y3

U9G Sun Hydraulics Danfoss OMV: Cross pilot with shuttle Motor mount manifold drawing U9G – Sun Hydraulics Danfoss OMV: Cross pilot with shuttle Motor mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDCLHN-U9G/Y3

CBDB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBLHN-BBE/Y3

BBE Sun Hydraulics ISO 05: B to T, port 3 external Sandwich manifold drawing BBE – Sun Hydraulics ISO 05: B to T, port 3 external Sandwich manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDBLHN-BBE/Y3

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-U9G/Y3

U9G Sun Hydraulics Danfoss OMV: Cross pilot with shuttle Motor mount manifold drawing U9G – Sun Hydraulics Danfoss OMV: Cross pilot with shuttle Motor mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDALHN-U9G/Y3

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-BBF/Y3

BBF Sun Hydraulics ISO 05: On A or B, port 3 external Sandwich manifold drawing BBF – Sun Hydraulics ISO 05: On A or B, port 3 external Sandwich manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CAEGLGN-BBF/Y3

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-W6C/Y1

W6C Sun Hydraulics Direct mount Line mount manifold drawing W6C – Sun Hydraulics Direct mount Line mount manifold - /Y1 – 65-45-12 Ductile Iron, Viton, Clear Zinc Nickel with Top Sealer
Assembly:

CBDAXNN-W6C/Y1

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-BGJ

BGJ Sun Hydraulics Ninety degree with shuttle Line mount manifold drawing BGJ – Sun Hydraulics Ninety degree with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEKLHN-BGJ

CXFHZ-CN Sun Hydraulics Position Indication Valve – installation dimensions drawing, cavity T-5A CXFHZ-CN – Sun Hydraulics Free flow nose to side check valve with position switch - N – Buna-N
Assembly:

CXFHZCN-ZHG/S

ZHG Sun Hydraulics Direct mount Line mount manifold drawing ZHG – Sun Hydraulics Direct mount Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CXFHZCN-ZHG/S

CBDB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBLHN-B8B/Y3

B8B Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold drawing B8B – Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDBLHN-B8B/Y3

CNAC-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-162A CNAC-XCN – Sun Hydraulics Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check - Standard Material/Coating
Assembly:

CNACXCN-AAH

AAH Sun Hydraulics Ninety degree Line mount manifold drawing AAH – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CNACXCN-AAH

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-B2J/Y3

B2J Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing B2J – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CAEGLGN-B2J/Y3

RPET-LWN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPET-LWN – Sun Hydraulics Anti-Shock, pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPETLWN-ZDD/Y1

ZDD Sun Hydraulics Flange mount through port Line mount manifold drawing ZDD – Sun Hydraulics Flange mount through port Line mount manifold - /Y1 – 65-45-12 Ductile Iron, Viton, Clear Zinc Nickel with Top Sealer
Assembly:

RPETLWN-ZDD/Y1

CBHG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHGLJN-K4E/Y4

K4E Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K4E – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBHGLJN-K4E/Y4

Back To Shop

Cart totals

Subtotal
Total

Main Menu