Product Price Quantity Total  
CBFG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFGLJN-ZTV

ZTV Sun Hydraulics Direct mount Line mount manifold drawing ZTV – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFGLJN-ZTV

RBUY-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity SC-10-02 RBUY-LAN – Sun Hydraulics Bi-directional, direct-acting relief valve - common cavity - N – Buna-N
Assembly:

RBUYLAN-JND

JND Sun Hydraulics Ninety degree Line mount manifold drawing JND – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RBUYLAN-JND

CWGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGALHN-PCX/S3

PCX Sun Hydraulics Ninety degree Line mount manifold drawing PCX – Sun Hydraulics Ninety degree Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CWGALHN-PCX/S3

CBIG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIG-LJN – Sun Hydraulics 4.5:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBIGLJN-KHS

KHS Sun Hydraulics Through port 1 with gauge port Line mount manifold drawing KHS – Sun Hydraulics Through port 1 with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBIGLJN-KHS

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-X9J

X9J Sun Hydraulics Direct mount, cross pilot Line mount manifold drawing X9J – Sun Hydraulics Direct mount, cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFLLJN-X9J

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-WZU

WZU Sun Hydraulics Danfoss OMP/OMR: Cross pilot with shuttle Motor mount manifold drawing WZU – Sun Hydraulics Danfoss OMP/OMR: Cross pilot with shuttle Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-WZU

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-YVF/S5

YVF Sun Hydraulics Cross pilot Line mount manifold drawing YVF – Sun Hydraulics Cross pilot Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CBDCXNN-YVF/S5

RBAA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBAA-LAN – Sun Hydraulics Direct-acting relief valve - pilot capacity - Standard Material/Coating
Assembly:

RBAALAN-VNG/S

VNG Sun Hydraulics 1 Station, Parallel circuit with relief cavity Bar manifold manifold drawing VNG – Sun Hydraulics 1 Station, Parallel circuit with relief cavity Bar manifold manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

RBAALAN-VNG/S

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-ECC/S4

ECC Sun Hydraulics Ninety degree Line mount manifold drawing ECC – Sun Hydraulics Ninety degree Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CBABXNN-ECC/S4

CAIA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAIALHN-WAP/Y5

WAP Sun Hydraulics All gasket ports Gasket mount manifold drawing WAP – Sun Hydraulics All gasket ports Gasket mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CAIALHN-WAP/Y5

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-W6A

W6A Sun Hydraulics Direct mount Line mount manifold drawing W6A – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-W6A

RBAB-ABN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBAB-ABN – Sun Hydraulics Air-controlled, direct-acting relief valve - pilot capacity - N – Buna-N
Assembly:

RBABABN-VLF/Y

VLF Sun Hydraulics 2 Station, Parallel circuit with relief cavity Bar manifold manifold drawing VLF – Sun Hydraulics 2 Station, Parallel circuit with relief cavity Bar manifold manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

RBABABN-VLF/Y

DFCA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-13A DFCA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - No coil
Assembly:

DFCAXCN-Z5R

Z5R Sun Hydraulics Common port 2 Line mount manifold drawing Z5R – Sun Hydraulics Common port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFCAXCN-Z5R

CWGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGALHN-PCN/S3

PCN Sun Hydraulics Ninety degree Line mount manifold drawing PCN – Sun Hydraulics Ninety degree Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CWGALHN-PCN/S3

Back To Shop

Cart totals

Subtotal
Total

Main Menu