Product Price Quantity Total  
CBFB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFBLHN-HC4

HC4 Sun Hydraulics Ninety degree Line mount manifold drawing HC4 – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFBLHN-HC4

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-VVP

VVP Sun Hydraulics 6 signal load sense shuttle body Line mount manifold drawing VVP – Sun Hydraulics 6 signal load sense shuttle body Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACKLHN-VVP

RPEN-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEN-LAN – Sun Hydraulics Electro-proportional relief valve - high pressure setting with no command (740 Series) - No coil
Assembly:

RPENLAN-YFM

YFM Sun Hydraulics Cross port Line mount manifold drawing YFM – Sun Hydraulics Cross port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPENLAN-YFM

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-YAB

YAB Sun Hydraulics Cross pilot Line mount manifold drawing YAB – Sun Hydraulics Cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDAXNN-YAB

CWGL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGLLGN-VAQ

VAQ Sun Hydraulics Cross pilot with independent port 4s Line mount manifold drawing VAQ – Sun Hydraulics Cross pilot with independent port 4s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CWGLLGN-VAQ

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-W8T

W8T Sun Hydraulics Nipple mount Line mount manifold drawing W8T – Sun Hydraulics Nipple mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-W8T

CBIA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIA-LHN – Sun Hydraulics 3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBIALHN-WYA

WYA Sun Hydraulics Sandwich mount through port Line mount manifold drawing WYA – Sun Hydraulics Sandwich mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBIALHN-WYA

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-ZFM

ZFM Sun Hydraulics Ninety degree Line mount manifold drawing ZFM – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-ZFM

CBGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGA-LHN – Sun Hydraulics 3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGALHN-HC4

HC4 Sun Hydraulics Ninety degree Line mount manifold drawing HC4 – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBGALHN-HC4

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-XAT

XAT Sun Hydraulics Inline, cross pilot Line mount manifold drawing XAT – Sun Hydraulics Inline, cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-XAT

CAGL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGLLGN-H4N

H4N Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing H4N – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGLLGN-H4N

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-XAT

XAT Sun Hydraulics Inline, cross pilot Line mount manifold drawing XAT – Sun Hydraulics Inline, cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDALHN-XAT

EVEC-XXV Sun Hydraulics Energy Harvester Valve – installation dimensions drawing, cavity T-16A EVEC-XXV – Sun Hydraulics 2-port energy harvester valve - V – Viton
Assembly:

EVECXXV-WNK

WNK Sun Hydraulics With bypass compensator Line mount manifold drawing WNK – Sun Hydraulics With bypass compensator Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

EVECXXV-WNK

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-W7W

W7W Sun Hydraulics Ninety degree, panel mount Line mount manifold drawing W7W – Sun Hydraulics Ninety degree, panel mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-W7W

DFEA8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEA8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2 - N – Buna-N
Assembly:

DFEA8DN-ZQD

ZQD Sun Hydraulics Sandwich mount through port Line mount manifold drawing ZQD – Sun Hydraulics Sandwich mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFEA8DN-ZQD

DACC-MCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-13A DACC-MCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - No coil
Assembly:

DACCMCN-GAL

GAL Sun Hydraulics Ninety degree Line mount manifold drawing GAL – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DACCMCN-GAL

CBFC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFCLHN-WHW

WHW Sun Hydraulics Nipple mount Line mount manifold drawing WHW – Sun Hydraulics Nipple mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFCLHN-WHW

CDAA-BBN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-13A CDAA-BBN – Sun Hydraulics Back-to-back check/shuttle valve with signal external - Standard Material/Coating
Assembly:

CDAABBN-XWR

XWR Sun Hydraulics Bidirectional Line mount manifold drawing XWR – Sun Hydraulics Bidirectional Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CDAABBN-XWR

RPEE-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEE-LAN – Sun Hydraulics Fast-acting, pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPEELAN-YFD

YFD Sun Hydraulics Cross port Line mount manifold drawing YFD – Sun Hydraulics Cross port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPEELAN-YFD

CABG-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABG-LHN – Sun Hydraulics 4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CABGLHN-ZFM

ZFM Sun Hydraulics Ninety degree Line mount manifold drawing ZFM – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABGLHN-ZFM

FCDC-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-5A FCDC-XAN – Sun Hydraulics Fixed-orifice pressure compensated flow control valve with reverse flow check - Standard Material/Coating
Assembly:

FCDCXAN-XWD

XWD Sun Hydraulics Bidirectional Line mount manifold drawing XWD – Sun Hydraulics Bidirectional Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FCDCXAN-XWD

DFCA8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-13A DFCA8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2 - Standard Material/Coating
Assembly:

DFCA8DN-XWR

XWR Sun Hydraulics Bidirectional Line mount manifold drawing XWR – Sun Hydraulics Bidirectional Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFCA8DN-XWR

DFEB-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEB-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 - No coil
Assembly:

DFEBXCN-YSJ

YSJ Sun Hydraulics Rectifier circuit Line mount manifold drawing YSJ – Sun Hydraulics Rectifier circuit Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFEBXCN-YSJ

DFCA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-13A DFCA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - No coil
Assembly:

DFCAXCN-XWR

XWR Sun Hydraulics Bidirectional Line mount manifold drawing XWR – Sun Hydraulics Bidirectional Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFCAXCN-XWR

DKHP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-23A DKHP-LAN – Sun Hydraulics Normally closed, balanced poppet, logic element - pressure adjustable - N – Buna-N
Assembly:

DKHPLAN-XMX

XMX Sun Hydraulics Cross pilot with common port 4s Line mount manifold drawing XMX – Sun Hydraulics Cross pilot with common port 4s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DKHPLAN-XMX

CWGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGALHN-XMN

XMN Sun Hydraulics Cross pilot with common port 4s Line mount manifold drawing XMN – Sun Hydraulics Cross pilot with common port 4s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CWGALHN-XMN

CBFG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFGLJN-H7F

H7F Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing H7F – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFGLJN-H7F

RPEC-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEC-LAN – Sun Hydraulics Pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPECLAN-Z4Z

Z4Z Sun Hydraulics Through port 1 with gauge port Line mount manifold drawing Z4Z – Sun Hydraulics Through port 1 with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPECLAN-Z4Z

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-XAT

XAT Sun Hydraulics Inline, cross pilot Line mount manifold drawing XAT – Sun Hydraulics Inline, cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-XAT

CDAC-BBN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-13A CDAC-BBN – Sun Hydraulics Back-to-back check/shuttle valve with signal at port 2 - N – Buna-N
Assembly:

CDACBBN-U9L

U9L Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing U9L – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CDACBBN-U9L

RPET-LWN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPET-LWN – Sun Hydraulics Anti-Shock, pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPETLWN-VZF

VZF Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross port Motor mount manifold drawing VZF – Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross port Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPETLWN-VZF

RBAA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBAA-LAN – Sun Hydraulics Direct-acting relief valve - pilot capacity - Standard Material/Coating
Assembly:

RBAALAN-ZBT

ZBT Sun Hydraulics Flange mount through port Line mount manifold drawing ZBT – Sun Hydraulics Flange mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RBAALAN-ZBT

Back To Shop

Cart totals

Subtotal
Total

Main Menu