Product Price Quantity Total  
CWGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGGLGN-PAW/S4

PAW Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing PAW – Sun Hydraulics Ninety degree with gauge port Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CWGGLGN-PAW/S4

DFDB8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-5A DFDB8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 2-1 - N – Buna-N
Assembly:

DFDB8DN-ZHG/Y5

ZHG Sun Hydraulics Direct mount Line mount manifold drawing ZHG – Sun Hydraulics Direct mount Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

DFDB8DN-ZHG/Y5

DNUC-XCN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity SC-10-04 DNUC-XCN – Sun Hydraulics 4-way, 3-position, solenoid-operated directional spool valve, 3600 psi (250 bar) - common cavity - No coil
Assembly:

DNUCXCN-JPD

JPD Sun Hydraulics Ninety degree Line mount manifold drawing JPD – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DNUCXCN-JPD

DOJP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DOJP-LAN – Sun Hydraulics Normally open, balanced poppet, logic element - pressure adjustable - Standard Material/Coating
Assembly:

DOJPLAN-Q4W/S4

Q4W Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4W – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

DOJPLAN-Q4W/S4

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-U3D

U3D Sun Hydraulics Inline Line mount manifold drawing U3D – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGALHN-U3D

CVEV-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-22A CVEV-XCN – Sun Hydraulics Vented pilot-to-open check valve - Standard Material/Coating
Assembly:

CVEVXCN-NAV

NAV Sun Hydraulics Ninety degree Line mount manifold drawing NAV – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CVEVXCN-NAV

CBFB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFBLHN-H4E

H4E Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing H4E – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFBLHN-H4E

CABN-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABN-LHN – Sun Hydraulics 7:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CABNLHN-E3B

E3B Sun Hydraulics Through port 2 with reverse flow check Line mount manifold drawing E3B – Sun Hydraulics Through port 2 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABNLHN-E3B

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-B6B

B6B Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing B6B – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEGLGN-B6B

CBGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGA-LHN – Sun Hydraulics 3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGALHN-WXW

WXW Sun Hydraulics Flange mount through port Line mount manifold drawing WXW – Sun Hydraulics Flange mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBGALHN-WXW

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-VGO/S3

VGO Sun Hydraulics Eaton/Char-Lynn H & S: Cross pilot Motor mount manifold drawing VGO – Sun Hydraulics Eaton/Char-Lynn H & S: Cross pilot Motor mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDAXNN-VGO/S3

DFDJ-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-5A DFDJ-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series) - No coil
Assembly:

DFDJXCN-VFG

VFG Sun Hydraulics Inline Line mount manifold drawing VFG – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFDJXCN-VFG

CBFC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFCLHN-H8Y

H8Y Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold drawing H8Y – Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFCLHN-H8Y

CBFD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFDLJN-ZJH

ZJH Sun Hydraulics Direct mount Line mount manifold drawing ZJH – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFDLJN-ZJH

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-VGN

VGN Sun Hydraulics Eaton/Char-Lynn H & S: Cross pilot Motor mount manifold drawing VGN – Sun Hydraulics Eaton/Char-Lynn H & S: Cross pilot Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-VGN

MBIGX-MN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A MBIGX-MN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, load reactive, load control valve - Standard Material/Coating
Assembly:

MBIGXMN-BKO

BKO Sun Hydraulics ISO 07: On P, port 3 to T Sandwich manifold drawing BKO – Sun Hydraulics ISO 07: On P, port 3 to T Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

MBIGXMN-BKO

RPEC8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEC8-WN – Sun Hydraulics Pilot-operated, balanced piston relief main stage with integral T-8A control cavity - N – Buna-N
Assembly:

RPEC8WN-FHB/Y3

FHB Sun Hydraulics Cross port with make up checks Line mount manifold drawing FHB – Sun Hydraulics Cross port with make up checks Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

RPEC8WN-FHB/Y3

Back To Shop

Cart totals

Subtotal
Total

Main Menu