Product Price Quantity Total  
CWGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGGLGN-VFZ

VFZ Sun Hydraulics Direct mount, cross pilot Gasket mount manifold drawing VFZ – Sun Hydraulics Direct mount, cross pilot Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CWGGLGN-VFZ

CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-VYV

VYV Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold drawing VYV – Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDLJN-VYV

RPGE-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RPGE-LAN – Sun Hydraulics Fast-acting, pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPGELAN-CAE

CAE Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing CAE – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPGELAN-CAE

DKDR-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-21A DKDR-XHN – Sun Hydraulics Normally closed, balanced poppet, logic element - vent-to-open - Standard Material/Coating
Assembly:

DKDRXHN-MAC

MAC Sun Hydraulics Ninety degree Line mount manifold drawing MAC – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DKDRXHN-MAC

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-BB3

BB3 Sun Hydraulics ISO 05: Reducer on B with reverse flow check Sandwich manifold drawing BB3 – Sun Hydraulics ISO 05: Reducer on B with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDALHN-BB3

LRDA-XHN Sun Hydraulics Modulating Spool Valve – installation dimensions drawing, cavity T-11A LRDA-XHN – Sun Hydraulics Normally closed, modulating element with pilot source from port 1 - Standard Material/Coating
Assembly:

LRDAXHN-A7A

A7A Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A7A – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LRDAXHN-A7A

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-5BD

5BD Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold drawing 5BD – Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCXNN-5BD

CBIL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIL-LJN – Sun Hydraulics 2.3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBILLJN-ZNS

ZNS Sun Hydraulics Sandwich mount through port Line mount manifold drawing ZNS – Sun Hydraulics Sandwich mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBILLJN-ZNS

DKFP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-22A DKFP-LAN – Sun Hydraulics Normally closed, balanced poppet, logic element - pressure adjustable - N – Buna-N
Assembly:

DKFPLAN-N4C

N4C Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4C – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DKFPLAN-N4C

RBAE-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-8A RBAE-LAN – Sun Hydraulics Direct-acting relief valve - pilot capacity - Standard Material/Coating
Assembly:

RBAELAN-WFM

WFM Sun Hydraulics Ninety degree Line mount manifold drawing WFM – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RBAELAN-WFM

PVFA-LAN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-22A PVFA-LAN – Sun Hydraulics Pilot-operated, pressure reducing/relieving valve with drain to port 4 - Standard Material/Coating
Assembly:

PVFALAN-N4L

N4L Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4L – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PVFALAN-N4L

QCDB-LAN Sun Hydraulics Accumulator Sense, Pump Unload Valve – installation dimensions drawing, cavity T-21A QCDB-LAN – Sun Hydraulics 20%, accumulator sense, pump unload valve with check - pilot capacity - Standard Material/Coating
Assembly:

QCDBLAN-M4J

M4J Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4J – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

QCDBLAN-M4J

DCED-XCN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity T-63A DCED-XCN – Sun Hydraulics 4-way, 2-position, pilot-to-shift, detented, directional valve - Standard Material/Coating
Assembly:

DCEDXCN-PPL

PPL Sun Hydraulics Ninety degree Line mount manifold drawing PPL – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DCEDXCN-PPL

RVBB-LAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-163A RVBB-LAN – Sun Hydraulics Normally closed modulating element valve with relief function - N – Buna-N
Assembly:

RVBBLAN-J6U

J6U Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing J6U – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RVBBLAN-J6U

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-BMD

BMD Sun Hydraulics Cushion lock Line mount manifold drawing BMD – Sun Hydraulics Cushion lock Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDAXNN-BMD

CKCS-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-11A CKCS-XCN – Sun Hydraulics 5:1 pilot ratio, pilot-to-open check valve with sealed pilot - N – Buna-N
Assembly:

CKCSXCN-A2C

A2C Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2C – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CKCSXCN-A2C

DAAH-BCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-8A DAAH-BCN – Sun Hydraulics 2-way, hydraulically operated, spool directional valve - pilot capacity - Standard Material/Coating
Assembly:

DAAHBCN-WFO

WFO Sun Hydraulics Ninety degree Line mount manifold drawing WFO – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DAAHBCN-WFO

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-E2A

E2A Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing E2A – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACKLHN-E2A

CBHA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHALHN-K2D

K2D Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2D – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBHALHN-K2D

CBDB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBLHN-ZXT

ZXT Sun Hydraulics Direct mount Line mount manifold drawing ZXT – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBLHN-ZXT

LODA8-DN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-11A LODA8-DN – Sun Hydraulics Vent-to-open, spring-biased closed, unbalanced poppet logic element with pilot source from port 1 and integral T-8A control cavity - Standard Material/Coating
Assembly:

LODA8DN-A2K

A2K Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2K – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LODA8DN-A2K

FVCA-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-21A FVCA-XAN – Sun Hydraulics Ventable, fixed-orifice, bypass/restrictive, priority flow control valve - N – Buna-N
Assembly:

FVCAXAN-MAC

MAC Sun Hydraulics Ninety degree Line mount manifold drawing MAC – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FVCAXAN-MAC

CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-BIC

BIC Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold drawing BIC – Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDLJN-BIC

Back To Shop

Cart totals

Subtotal
Total

Main Menu