Product Price Quantity Total  
DKFR-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-22A DKFR-XHN – Sun Hydraulics Normally closed, balanced poppet, logic element - vent-to-open - N – Buna-N
Assembly:

DKFRXHN-XRC/S5

XRC Sun Hydraulics Cross pilot with independent port 4s Line mount manifold drawing XRC – Sun Hydraulics Cross pilot with independent port 4s Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

DKFRXHN-XRC/S5

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-BHV

BHV Sun Hydraulics Through port 1 with gauge port Line mount manifold drawing BHV – Sun Hydraulics Through port 1 with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDXXN-BHV

DOHR-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-23A DOHR-XHN – Sun Hydraulics Normally open, balanced poppet, logic element - vent-to-close - N – Buna-N
Assembly:

DOHRXHN-P4X

P4X Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing P4X – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DOHRXHN-P4X

CNHC-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-16A CNHC-XCN – Sun Hydraulics Free flow nose to side check valve with bypass orifice - Standard Material/Coating
Assembly:

CNHCXCN-CDW

CDW Sun Hydraulics ISO 08: A to B and B to A Sandwich manifold drawing CDW – Sun Hydraulics ISO 08: A to B and B to A Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CNHCXCN-CDW

DFEJ-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEJ-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series) - No coil
Assembly:

DFEJXCN-ZUM

ZUM Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing ZUM – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFEJXCN-ZUM

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-4BW/S

4BW Sun Hydraulics Cushion lock with make up checks Line mount manifold drawing 4BW – Sun Hydraulics Cushion lock with make up checks Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CAEKLHN-4BW/S

CVGV-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-23A CVGV-XCN – Sun Hydraulics Vented pilot-to-open check valve - Standard Material/Coating
Assembly:

CVGVXCN-W6W

W6W Sun Hydraulics Direct mount Line mount manifold drawing W6W – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CVGVXCN-W6W

XDCA-XXN Sun Hydraulics Cavity Plug Valve – hydraulic schematic symbol XDCA-XXN – Sun Hydraulics All ports blocked cavity plug - Standard Material/Coating
Assembly:

XDCAXXN-DAK

DAK Sun Hydraulics Ninety degree Line mount manifold drawing DAK – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

XDCAXXN-DAK

CAGK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAGKLHN-YJ5

YJ5 Sun Hydraulics Cross pilot Line mount manifold drawing YJ5 – Sun Hydraulics Cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGKLHN-YJ5

CXED-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-5A CXED-XCN – Sun Hydraulics Free flow side to nose check valve - Standard Material/Coating
Assembly:

CXEDXCN-WBW

WBW Sun Hydraulics Sandwich mount through port Line mount manifold drawing WBW – Sun Hydraulics Sandwich mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXEDXCN-WBW

CBIB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIB-LHN – Sun Hydraulics 1.5:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBIBLHN-K25/S5

K25 Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing K25 – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CBIBLHN-K25/S5

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-B7J

B7J Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing B7J – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDXXN-B7J

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-U9E/S

U9E Sun Hydraulics Danfoss OMV: Cross pilot with shuttle Motor mount manifold drawing U9E – Sun Hydraulics Danfoss OMV: Cross pilot with shuttle Motor mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CAEGLGN-U9E/S