Product Price Quantity Total  
CBFA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFALHN-YRS

YRS Sun Hydraulics Four port directional circuit using logic valves, NPT pilot ports Line mount manifold drawing YRS – Sun Hydraulics Four port directional circuit using logic valves, NPT pilot ports Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFALHN-YRS

DMDAZ-BN224 Sun Hydraulics 3-way Valve – installation dimensions drawing, cavity T-11A DMDAZ-BN224 – Sun Hydraulics 3-way, solenoid-operated directional spool valve with position switch - 224 – DIN 43650-Form A, 24 VDC
Assembly:

DMDAZBN224-A2J

A2J Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2J – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DMDAZBN224-A2J

FCDC-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-5A FCDC-XAN – Sun Hydraulics Fixed-orifice pressure compensated flow control valve with reverse flow check - Standard Material/Coating
Assembly:

FCDCXAN-XWB

XWB Sun Hydraulics Bidirectional Line mount manifold drawing XWB – Sun Hydraulics Bidirectional Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FCDCXAN-XWB

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-BTV

BTV Sun Hydraulics On P, port 3 to T, manifold T port Sub plate manifold drawing BTV – Sun Hydraulics On P, port 3 to T, manifold T port Sub plate manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-BTV

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-VVV

VVV Sun Hydraulics 3 cylinder sequence, direct acting Line mount manifold drawing VVV – Sun Hydraulics 3 cylinder sequence, direct acting Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-VVV

RPEC-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEC-LAN – Sun Hydraulics Pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPECLAN-FMB/Y3

FMB Sun Hydraulics Cross port with make up checks Line mount manifold drawing FMB – Sun Hydraulics Cross port with make up checks Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

RPECLAN-FMB/Y3

RBAB-ABN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBAB-ABN – Sun Hydraulics Air-controlled, direct-acting relief valve - pilot capacity - N – Buna-N
Assembly:

RBABABN-VML/Y5

VML Sun Hydraulics 3 Station, Parallel circuit with relief cavity Bar manifold manifold drawing VML – Sun Hydraulics 3 Station, Parallel circuit with relief cavity Bar manifold manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

RBABABN-VML/Y5

CAIG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAIGLGN-KF8

KF8 Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing KF8 – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAIGLGN-KF8

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-ZTG

ZTG Sun Hydraulics Direct mount, cross pilot Gasket mount manifold drawing ZTG – Sun Hydraulics Direct mount, cross pilot Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-ZTG

RDDA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RDDA-LAN – Sun Hydraulics Direct-acting relief valve - Standard Material/Coating
Assembly:

RDDALAN-FNA

FNA Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing FNA – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RDDALAN-FNA

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-C6I

C6I Sun Hydraulics Ninety degree with high capacity port 3, gauge port, accepts standard and weatherized coils Line mount manifold drawing C6I – Sun Hydraulics Ninety degree with high capacity port 3, gauge port, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABXNN-C6I

DFFI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFFIXCN-LN8

LN8 Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing LN8 – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFFIXCN-LN8

FCDB-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-5A FCDB-XAN – Sun Hydraulics Fixed-orifice pressure compensated flow control valve with reverse flow check - Standard Material/Coating
Assembly:

FCDBXAN-ZLT

ZLT Sun Hydraulics Direct mount Line mount manifold drawing ZLT – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FCDBXAN-ZLT

CBAB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAB-LHN – Sun Hydraulics 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABLHN-EET

EET Sun Hydraulics Port 3 connected to port 1 Line mount manifold drawing EET – Sun Hydraulics Port 3 connected to port 1 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABLHN-EET

DNBF-XNN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity T-30A DNBF-XNN – Sun Hydraulics FLeX Series 4-way, 2-position, solenoid-operated directional spool valve - No coil
Assembly:

DNBFXNN-JKI

JKI Sun Hydraulics Ninety degree Line mount manifold drawing JKI – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DNBFXNN-JKI

CBFG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFGLJN-ZJH

ZJH Sun Hydraulics Direct mount Line mount manifold drawing ZJH – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFGLJN-ZJH

FCDB-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-5A FCDB-XAN – Sun Hydraulics Fixed-orifice pressure compensated flow control valve with reverse flow check - Standard Material/Coating
Assembly:

FCDBXAN-DAA

DAA Sun Hydraulics Ninety degree Line mount manifold drawing DAA – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FCDBXAN-DAA

DRCO-LAN Sun Hydraulics 3-way Valve – installation dimensions drawing, cavity T-22A DRCO-LAN – Sun Hydraulics 3-way, direct-acting, directional valve with drain to port 4 (1 blocked, 2 to 3 open) - N – Buna-N
Assembly:

DRCOLAN-N4I

N4I Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4I – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DRCOLAN-N4I

Back To Shop