Product Price Quantity Total  
RGFA-LCN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RGFA-LCN – Sun Hydraulics Low-pressure-range, direct-acting relief valve - Standard Material/Coating
Assembly:

RGFALCN-ZKA/Y4

ZKA Sun Hydraulics Flange mount through port Line mount manifold drawing ZKA – Sun Hydraulics Flange mount through port Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

RGFALCN-ZKA/Y4

CXFA-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-5A CXFA-XCN – Sun Hydraulics Free flow nose to side check valve - Standard Material/Coating
Assembly:

CXFAXCN-ZHG/S3

ZHG Sun Hydraulics Direct mount Line mount manifold drawing ZHG – Sun Hydraulics Direct mount Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CXFAXCN-ZHG/S3

MBGBX-LV Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A MBGBX-LV – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, load reactive, load control valve - V – Viton
Assembly:

MBGBXLV-BK6

BK6 Sun Hydraulics ISO 07: Sequence out of A with reverse flow check Sandwich manifold drawing BK6 – Sun Hydraulics ISO 07: Sequence out of A with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

MBGBXLV-BK6

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-ZYG/S3

ZYG Sun Hydraulics Direct mount Line mount manifold drawing ZYG – Sun Hydraulics Direct mount Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CAEKLHN-ZYG/S3

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-WEW/Y4

WEW Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold drawing WEW – Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CAGALHN-WEW/Y4

RSHC-LAN Sun Hydraulics Sequence Valve – installation dimensions drawing, cavity T-17A RSHC-LAN – Sun Hydraulics Pilot-operated, balanced piston sequence valve - /LH – Mild Steel, Zinc-Nickel
Assembly:

RSHCLAN/LH-BK5

BK5 Sun Hydraulics ISO 07: Sequence into B with reverse flow check Sandwich manifold drawing BK5 – Sun Hydraulics ISO 07: Sequence into B with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RSHCLAN/LH-BK5

CNCC-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-13A CNCC-XCN – Sun Hydraulics Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check - Standard Material/Coating
Assembly:

CNCCXCN-XWS/S3

XWS Sun Hydraulics Eaton/Char-Lynn H & S: Meter out A and B Motor mount manifold drawing XWS – Sun Hydraulics Eaton/Char-Lynn H & S: Meter out A and B Motor mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CNCCXCN-XWS/S3

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-EMU/Y3

EMU Sun Hydraulics Cushion lock Line mount manifold drawing EMU – Sun Hydraulics Cushion lock Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBAAXNN-EMU/Y3

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-ZWK/Y3

ZWK Sun Hydraulics Direct mount Line mount manifold drawing ZWK – Sun Hydraulics Direct mount Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDCXNN-ZWK/Y3

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-XVA/Y4

XVA Sun Hydraulics Eaton/Char-Lynn 2000-2speed: Cross pilot with shuttle Motor mount manifold drawing XVA – Sun Hydraulics Eaton/Char-Lynn 2000-2speed: Cross pilot with shuttle Motor mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBDBXNN-XVA/Y4

CABN-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABN-LHN – Sun Hydraulics 7:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CABNLHN-EQB/Y3

EQB Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold drawing EQB – Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CABNLHN-EQB/Y3

CXHHZ-CN Sun Hydraulics Position Indication Valve – hydraulic schematic symbol CXHHZ-CN – Sun Hydraulics Free flow nose to side check valve with position switch - N – Buna-N
Assembly:

CXHHZCN-ICN/S3

ICN Sun Hydraulics Inline Line mount manifold drawing ICN – Sun Hydraulics Inline Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CXHHZCN-ICN/S3

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-ZYG/Y4

ZYG Sun Hydraulics Direct mount Line mount manifold drawing ZYG – Sun Hydraulics Direct mount Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBDALHN-ZYG/Y4

CBGB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGB-LHN – Sun Hydraulics 1.5:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGBLHN-ZNW

ZNW Sun Hydraulics Direct mount Line mount manifold drawing ZNW – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBGBLHN-ZNW

CAEL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAELLGN-BBD/W4

BBD Sun Hydraulics ISO 05: A to T, port 3 external Sandwich manifold drawing BBD – Sun Hydraulics ISO 05: A to T, port 3 external Sandwich manifold - /W4 – 65-45-12 Ductile Iron, Metric, Viton, Chem. Black
Assembly:

CAELLGN-BBD/W4

CBDB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBLHN-B7V/Y3

B7V Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing B7V – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDBLHN-B7V/Y3

CBAB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAB-LHN – Sun Hydraulics 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABLHN-ZVN/Y3

ZVN Sun Hydraulics Direct mount Line mount manifold drawing ZVN – Sun Hydraulics Direct mount Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBABLHN-ZVN/Y3

DKHR8-HN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-23A DKHR8-HN – Sun Hydraulics Normally closed, balanced poppet, logic element with integral T-8A control cavity - vent-to-open - N – Buna-N
Assembly:

DKHR8HN-P45/T4

P45 Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing P45 – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /T4 – 65-45-12 Ductile Iron, Metric, Buna-N, Chem. Black
Assembly:

DKHR8HN-P45/T4

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-A7C/Y4

A7C Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A7C – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBAAXNN-A7C/Y4

CBHG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHGLJN-ZNY/T5

ZNY Sun Hydraulics Direct mount Line mount manifold drawing ZNY – Sun Hydraulics Direct mount Line mount manifold - /T5 – 65-45-12 Ductile Iron, Metric, Buna-N, Electroless Nickel
Assembly:

CBHGLJN-ZNY/T5

FKGB-XCN Sun Hydraulics Throttle Valve – installation dimensions drawing, cavity T-23A FKGB-XCN – Sun Hydraulics 2-way, pilot-shifted, proportional throttle with bleed down, high capacity - N – Buna-N
Assembly:

FKGBXCN-P4D

P4D Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing P4D – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FKGBXCN-P4D

CAGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGGLGN-WEW/Y4

WEW Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold drawing WEW – Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CAGGLGN-WEW/Y4

RDFA3-AN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RDFA3-AN – Sun Hydraulics Non-adjustable direct-acting relief valve - N – Buna-N
Assembly:

RDFA3AN-VDT/S3

VDT Sun Hydraulics Cross port with gauge ports Line mount manifold drawing VDT – Sun Hydraulics Cross port with gauge ports Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RDFA3AN-VDT/S3

Back To Shop

Cart totals

Subtotal
Total

Main Menu