Product Price Quantity Total  
CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-B6W

B6W Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing B6W – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-B6W

CBFD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFDLJN-ZEL

ZEL Sun Hydraulics Ninety degree Line mount manifold drawing ZEL – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFDLJN-ZEL

CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-BBD

BBD Sun Hydraulics ISO 05: A to T, port 3 external Sandwich manifold drawing BBD – Sun Hydraulics ISO 05: A to T, port 3 external Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDLJN-BBD

CBFG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFGLJN-H7E

H7E Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing H7E – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFGLJN-H7E

CBAA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAA-LHN – Sun Hydraulics 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAALHN-XTT/S4

XTT Sun Hydraulics Eaton/Char-Lynn H & S: Cross pilot with shuttle Motor mount manifold drawing XTT – Sun Hydraulics Eaton/Char-Lynn H & S: Cross pilot with shuttle Motor mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CBAALHN-XTT/S4

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-E3B

E3B Sun Hydraulics Through port 2 with reverse flow check Line mount manifold drawing E3B – Sun Hydraulics Through port 2 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABXNN-E3B

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-ENB

ENB Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing ENB – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABKLHN-ENB

CAGL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGLLGN-WTI/S4

WTI Sun Hydraulics Through port 2 with high capacity port 3 and gauge port Line mount manifold drawing WTI – Sun Hydraulics Through port 2 with high capacity port 3 and gauge port Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CAGLLGN-WTI/S4

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-WSI

WSI Sun Hydraulics Through port 2 with gauge port Line mount manifold drawing WSI – Sun Hydraulics Through port 2 with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCXNN-WSI

CAGL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGLLGN-ZNW/S3

ZNW Sun Hydraulics Direct mount Line mount manifold drawing ZNW – Sun Hydraulics Direct mount Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CAGLLGN-ZNW/S3

CWGK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGKLHN-XM5

XM5 Sun Hydraulics Cross pilot with common port 4s Line mount manifold drawing XM5 – Sun Hydraulics Cross pilot with common port 4s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CWGKLHN-XM5

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-W6C

W6C Sun Hydraulics Direct mount Line mount manifold drawing W6C – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCXNN-W6C

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-XAC

XAC Sun Hydraulics Inline, cross pilot Line mount manifold drawing XAC – Sun Hydraulics Inline, cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEGLGN-XAC

RPES-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPES-LAN – Sun Hydraulics Pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPESLAN-VEV/S3

VEV Sun Hydraulics Danfoss OMS: Cross port with shuttle Motor mount manifold drawing VEV – Sun Hydraulics Danfoss OMS: Cross port with shuttle Motor mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RPESLAN-VEV/S3

PSFB-LAN Sun Hydraulics Reducing/Relieving Valve – hydraulic schematic symbol PSFB-LAN – Sun Hydraulics Direct-acting, pressure reducing/relieving valve with drain to port 4 - N – Buna-N
Assembly:

PSFBLAN-N4U

N4U Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4U – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PSFBLAN-N4U

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-VVV

VVV Sun Hydraulics 3 cylinder sequence, direct acting Line mount manifold drawing VVV – Sun Hydraulics 3 cylinder sequence, direct acting Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDALHN-VVV

CDAA-BBN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-13A CDAA-BBN – Sun Hydraulics Back-to-back check/shuttle valve with signal external - Standard Material/Coating
Assembly:

CDAABBN-Z5X

Z5X Sun Hydraulics Common port 1 Line mount manifold drawing Z5X – Sun Hydraulics Common port 1 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CDAABBN-Z5X

RDFA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RDFA-LAN – Sun Hydraulics Direct-acting relief valve - Standard Material/Coating
Assembly:

RDFALAN-CJA/T

CJA Sun Hydraulics ISO 05 - X&Y: A to T Sandwich manifold drawing CJA – Sun Hydraulics ISO 05 - X&Y: A to T Sandwich manifold - /T – 65-45-12 Ductile Iron, Metric, Buna-N, Dewatering Oil
Assembly:

RDFALAN-CJA/T

Back To Shop

Cart totals

Subtotal
Total

Main Menu