Product Price Quantity Total  
CAGK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAGKLHN-ZPK/S

ZPK Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing ZPK – Sun Hydraulics Ninety degree with gauge port Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CAGKLHN-ZPK/S

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-B5K/Y

B5K Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold drawing B5K – Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CBDCXNN-B5K/Y

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-ZXW/Y5

ZXW Sun Hydraulics Direct mount Line mount manifold drawing ZXW – Sun Hydraulics Direct mount Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CBDDXXN-ZXW/Y5

DKHD-EHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-17A DKHD-EHN – Sun Hydraulics Normally closed, balanced poppet, logic element - vent-to-open - V – Viton
Assembly:

DKHDEHV-BK9

BK9 Sun Hydraulics ISO 07: Reducer on A and B with reverse flow check Sandwich manifold drawing BK9 – Sun Hydraulics ISO 07: Reducer on A and B with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DKHDEHV-BK9

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-BDU/S

BDU Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing BDU – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CAEKLHN-BDU/S

CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-B8C/Y

B8C Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold drawing B8C – Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CBDDLJN-B8C/Y

CXBG-XAN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-162A CXBG-XAN – Sun Hydraulics Flush mount, free flow nose to side check valve - Standard Material/Coating
Assembly:

CXBGXAN-AAB/S3

AAB Sun Hydraulics Ninety degree Line mount manifold drawing AAB – Sun Hydraulics Ninety degree Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CXBGXAN-AAB/S3

CBFB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFBLHN-W9R/T3

W9R Sun Hydraulics Danfoss OMT: Direct mount Motor mount manifold drawing W9R – Sun Hydraulics Danfoss OMT: Direct mount Motor mount manifold - /T3 – 65-45-12 Ductile Iron, Metric, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBFBLHN-W9R/T3

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-B8C/Y3

B8C Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold drawing B8C – Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDBXNN-B8C/Y3

CBIB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIB-LHN – Sun Hydraulics 1.5:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBIBLHN-WAP/Y5

WAP Sun Hydraulics All gasket ports Gasket mount manifold drawing WAP – Sun Hydraulics All gasket ports Gasket mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CBIBLHN-WAP/Y5

CAIK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAIKLHN-K2L/S5

K2L Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2L – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CAIKLHN-K2L/S5

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-B2V/Y4

B2V Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing B2V – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBDCLHN-B2V/Y4

CXHA-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-16A CXHA-XCN – Sun Hydraulics Free flow nose to side check valve - Standard Material/Coating
Assembly:

CXHAXCN-U3E

U3E Sun Hydraulics Flange mount through port Line mount manifold drawing U3E – Sun Hydraulics Flange mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXHAXCN-U3E

DSGY-XEN Sun Hydraulics Diverter Valve – installation dimensions drawing, cavity T-33A DSGY-XEN – Sun Hydraulics 3-way, 2-position, vent-to-shift diverter valve, normally open - N – Buna-N
Assembly:

DSGYXEN-PMQ/T5

PMQ Sun Hydraulics Ninety degree Line mount manifold drawing PMQ – Sun Hydraulics Ninety degree Line mount manifold - /T5 – 65-45-12 Ductile Iron, Metric, Buna-N, Electroless Nickel
Assembly:

DSGYXEN-PMQ/T5

CBHG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHGLJN-K2L/Y3

K2L Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2L – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBHGLJN-K2L/Y3

CXDA-XAN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-13A CXDA-XAN – Sun Hydraulics Free flow nose to side check valve - Standard Material/Coating
Assembly:

CXDAXAN-VGB/S

VGB Sun Hydraulics Series circuit, 2 to 2 Line mount manifold drawing VGB – Sun Hydraulics Series circuit, 2 to 2 Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CXDAXAN-VGB/S

CXFHZ-CN Sun Hydraulics Position Indication Valve – installation dimensions drawing, cavity T-5A CXFHZ-CN – Sun Hydraulics Free flow nose to side check valve with position switch - N – Buna-N
Assembly:

CXFHZCN-DAW/S5

DAW Sun Hydraulics Ninety degree Line mount manifold drawing DAW – Sun Hydraulics Ninety degree Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CXFHZCN-DAW/S5

Back To Shop

Cart totals

Subtotal
Total