Product Price Quantity Total  
CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-EQV

EQV Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold drawing EQV – Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-EQV

NQEB-XAN Sun Hydraulics Air bleed and start-up Valve – installation dimensions drawing, cavity T-3A NQEB-XAN – Sun Hydraulics Air bleed and start-up valve - Standard Material/Coating
Assembly:

NQEBXAN-CBP

CBP Sun Hydraulics ISO 05: P to T Sandwich manifold drawing CBP – Sun Hydraulics ISO 05: P to T Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

NQEBXAN-CBP

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-E9B

E9B Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold drawing E9B – Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABXNN-E9B

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-A8U

A8U Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A8U – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-A8U

CBFA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFALHN-U3D

U3D Sun Hydraulics Inline Line mount manifold drawing U3D – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFALHN-U3D

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-EDU

EDU Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing EDU – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-EDU

CWGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGALHN-ZEV

ZEV Sun Hydraulics Direct mount Line mount manifold drawing ZEV – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CWGALHN-ZEV

DOJP-LAN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DOJP-LAN – Sun Hydraulics Normally open, balanced poppet, logic element - pressure adjustable - Standard Material/Coating
Assembly:

DOJPLAN-XSR

XSR Sun Hydraulics Cross pilot with independent port 4s Line mount manifold drawing XSR – Sun Hydraulics Cross pilot with independent port 4s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DOJPLAN-XSR

CBGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGA-LHN – Sun Hydraulics 3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGALHN-HDW

HDW Sun Hydraulics Inline Line mount manifold drawing HDW – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBGALHN-HDW

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-BBB

BBB Sun Hydraulics ISO 05: On B, port 3 to A Sandwich manifold drawing BBB – Sun Hydraulics ISO 05: On B, port 3 to A Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDALHN-BBB

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-HCL

HCL Sun Hydraulics Ninety degree Line mount manifold drawing HCL – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGALHN-HCL

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-EGT

EGT Sun Hydraulics Ninety degree with shuttle Line mount manifold drawing EGT – Sun Hydraulics Ninety degree with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABXNN-EGT

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-E6T

E6T Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing E6T – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-E6T

CSAC-BXN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-13A CSAC-BXN – Sun Hydraulics Single ball shuttle valve with signal at port 2 - Standard Material/Coating
Assembly:

CSACBXN-A5J

A5J Sun Hydraulics Common port 2 with coil clearance Line mount manifold drawing A5J – Sun Hydraulics Common port 2 with coil clearance Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CSACBXN-A5J

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-BND

BND Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing BND – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDALHN-BND

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-BTC/S

BTC Sun Hydraulics On P, port 3 to T, manifold T port Sub plate manifold drawing BTC – Sun Hydraulics On P, port 3 to T, manifold T port Sub plate manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CBDCXNN-BTC/S

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-EPV

EPV Sun Hydraulics Cushion lock with make up checks Line mount manifold drawing EPV – Sun Hydraulics Cushion lock with make up checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAAXNN-EPV

DMDM-LAN Sun Hydraulics 3-way Valve – installation dimensions drawing, cavity T-11A DMDM-LAN – Sun Hydraulics 3-way, manually operated, directional spool valve - N – Buna-N
Assembly:

DMDMLAN-A7A

A7A Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A7A – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DMDMLAN-A7A

CABG-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABG-LHN – Sun Hydraulics 4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CABGLHN-E9V

E9V Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold drawing E9V – Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABGLHN-E9V

RPEP-XAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEP-XAN – Sun Hydraulics Electro-proportional pilot-operated relief valve (740 Series) - No coil
Assembly:

RPEPXAN-CBH

CBH Sun Hydraulics ISO 05: A to B or B to A Sandwich manifold drawing CBH – Sun Hydraulics ISO 05: A to B or B to A Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPEPXAN-CBH

CBFD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFDLJN-XYK

XYK Sun Hydraulics Staffa 4", 5 piston: Cross pilot Motor mount manifold drawing XYK – Sun Hydraulics Staffa 4", 5 piston: Cross pilot Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFDLJN-XYK

RBDA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RBDA-LAN – Sun Hydraulics Bi-directional, direct-acting relief valve - N – Buna-N
Assembly:

RBDALAN-YFV

YFV Sun Hydraulics Cross port Line mount manifold drawing YFV – Sun Hydraulics Cross port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RBDALAN-YFV

CBAB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAB-LHN – Sun Hydraulics 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABLHN-E2I

E2I Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing E2I – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABLHN-E2I

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-BJS/V

BJS Sun Hydraulics ISO 05 - X&Y: Load sense from A or B to Y port Sandwich manifold drawing BJS – Sun Hydraulics ISO 05 - X&Y: Load sense from A or B to Y port Sandwich manifold - /V – 6061-T651 Aluminum, Viton
Assembly:

CABKLHN-BJS/V

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-YEV

YEV Sun Hydraulics Cross pilot Line mount manifold drawing YEV – Sun Hydraulics Cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABXNN-YEV

RBAA-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RBAA-LAN – Sun Hydraulics Direct-acting relief valve - pilot capacity - Standard Material/Coating
Assembly:

RBAALAN-VNR

VNR Sun Hydraulics 3 Station, Parallel circuit with relief cavity Bar manifold manifold drawing VNR – Sun Hydraulics 3 Station, Parallel circuit with relief cavity Bar manifold manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RBAALAN-VNR

PVDA-LAN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-21A PVDA-LAN – Sun Hydraulics Pilot-operated, pressure reducing/relieving valve with drain to port 4 - Standard Material/Coating
Assembly:

PVDALAN-M4J

M4J Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4J – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PVDALAN-M4J

CBDB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBLHN-BGI

BGI Sun Hydraulics Ninety degree with shuttle Line mount manifold drawing BGI – Sun Hydraulics Ninety degree with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBLHN-BGI

CBAA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAA-LHN – Sun Hydraulics 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAALHN-E3A

E3A Sun Hydraulics Through port 2 with reverse flow check Line mount manifold drawing E3A – Sun Hydraulics Through port 2 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAALHN-E3A

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-ZTJ

ZTJ Sun Hydraulics Direct mount, cross pilot Gasket mount manifold drawing ZTJ – Sun Hydraulics Direct mount, cross pilot Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFLLJN-ZTJ

RDDA3-AN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RDDA3-AN – Sun Hydraulics Non-adjustable direct-acting relief valve - Standard Material/Coating
Assembly:

RDDA3AN-VWC

VWC Sun Hydraulics Eaton/Char-Lynn 2000: Cross port Motor mount manifold drawing VWC – Sun Hydraulics Eaton/Char-Lynn 2000: Cross port Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RDDA3AN-VWC

FPBG-XDN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-162A FPBG-XDN – Sun Hydraulics FLeX Series pilot-operated, normally closed, electro-proportional throttle with reverse flow check - flow 2-1 - No coil
Assembly:

FPBGXDN-AAJ

AAJ Sun Hydraulics Ninety degree Line mount manifold drawing AAJ – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FPBGXDN-AAJ

DFBD-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DFBD-XCN – Sun Hydraulics FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1, 3000 psi (210 bar) - No coil
Assembly:

DFBDXCN-AYB

AYB Sun Hydraulics Cross port Line mount manifold drawing AYB – Sun Hydraulics Cross port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFBDXCN-AYB

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-B8B

B8B Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold drawing B8B – Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-B8B

CBFB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFBLHN-BK2

BK2 Sun Hydraulics ISO 07: Reducer on A with reverse flow check Sandwich manifold drawing BK2 – Sun Hydraulics ISO 07: Reducer on A with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFBLHN-BK2

CABG-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABG-LHN – Sun Hydraulics 4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CABGLHN-EIU

EIU Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold drawing EIU – Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABGLHN-EIU

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-5BL

5BL Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold drawing 5BL – Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-5BL

CACH-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACH-LGN – Sun Hydraulics 10:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CACHLGN-EEU

EEU Sun Hydraulics Port 3 connected to port 1 Line mount manifold drawing EEU – Sun Hydraulics Port 3 connected to port 1 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACHLGN-EEU

FRBA-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-163A FRBA-XAN – Sun Hydraulics Fixed-orifice, bypass/restrictive, priority, flow control valve - Standard Material/Coating
Assembly:

FRBAXAN-J2B

J2B Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing J2B – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FRBAXAN-J2B

RPEC8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEC8-WN – Sun Hydraulics Pilot-operated, balanced piston relief main stage with integral T-8A control cavity - N – Buna-N
Assembly:

RPEC8WN-FGB

FGB Sun Hydraulics Through port Line mount manifold drawing FGB – Sun Hydraulics Through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPEC8WN-FGB

CBFA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFALHN-BK8

BK8 Sun Hydraulics ISO 07: Cushion lock Sandwich manifold drawing BK8 – Sun Hydraulics ISO 07: Cushion lock Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFALHN-BK8

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-EIK

EIK Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold drawing EIK – Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-EIK

RVED-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-22A RVED-LAN – Sun Hydraulics Ventable, pilot-operated, balanced piston relief valve with drain to port 4 - N – Buna-N
Assembly:

RVEDLAN-N4K

N4K Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4K – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RVEDLAN-N4K

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-E9C

E9C Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold drawing E9C – Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACKLHN-E9C

CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-YPS

YPS Sun Hydraulics Four port directional circuit using logic valves, NPT pilot ports Line mount manifold drawing YPS – Sun Hydraulics Four port directional circuit using logic valves, NPT pilot ports Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDLJN-YPS

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-BKC

BKC Sun Hydraulics ISO 07: On A, port 3 external Sandwich manifold drawing BKC – Sun Hydraulics ISO 07: On A, port 3 external Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGALHN-BKC

DKFS-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-22A DKFS-XHN – Sun Hydraulics Normally closed, balanced poppet, logic element - pilot-to-open - Standard Material/Coating
Assembly:

DKFSXHN-N4B

N4B Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4B – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DKFSXHN-N4B

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-XVM

XVM Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold drawing XVM – Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABKLHN-XVM

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-E6I

E6I Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing E6I – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-E6I

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-E9J

E9J Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold drawing E9J – Sun Hydraulics 3 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACGLGN-E9J

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-HDE

HDE Sun Hydraulics Inline Line mount manifold drawing HDE – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFLLJN-HDE

Back To Shop

Cart totals

Subtotal
Total

Main Menu