Product Price Quantity Total  
CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-VYC/S3

VYC Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold drawing VYC – Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDDLJN-VYC/S3

CBFG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFGLJN-H6L

H6L Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing H6L – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFGLJN-H6L

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-XVL

XVL Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold drawing XVL – Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAAXNN-XVL

RPES-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPES-LAN – Sun Hydraulics Pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPESLAN-FCH/S3

FCH Sun Hydraulics Inline Line mount manifold drawing FCH – Sun Hydraulics Inline Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RPESLAN-FCH/S3

RPKS8-N Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-18A RPKS8-N – Sun Hydraulics Pilot-operated, balanced poppet relief main stage with integral T-8A control cavity - N – Buna-N
Assembly:

RPKS8N-LA2

LA2 Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing LA2 – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPKS8N-LA2

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-WPW

WPW Sun Hydraulics Inline, cross pilot Line mount manifold drawing WPW – Sun Hydraulics Inline, cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-WPW

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-WSJ

WSJ Sun Hydraulics Through port 2 with gauge port Line mount manifold drawing WSJ – Sun Hydraulics Through port 2 with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEGLGN-WSJ

DCDF-XXN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity T-62A DCDF-XXN – Sun Hydraulics 4-way, 2-position, pilot-to-shift directional valve - Standard Material/Coating
Assembly:

DCDFXXN-NPC/S3

NPC Sun Hydraulics Ninety degree Line mount manifold drawing NPC – Sun Hydraulics Ninety degree Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DCDFXXN-NPC/S3

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-B5W

B5W Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold drawing B5W – Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDAXNN-B5W

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-WFK

WFK Sun Hydraulics Ninety degree with high capacity port 3 Line mount manifold drawing WFK – Sun Hydraulics Ninety degree with high capacity port 3 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDAXNN-WFK

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-H2M/S3

H2M Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing H2M – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBFLLJN-H2M/S3

DFDI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-5A DFDI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFDIXCN-DND/S3

DND Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing DND – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DFDIXCN-DND/S3

CAGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGGLGN-HFE

HFE Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing HFE – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGGLGN-HFE

CABG-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABG-LHN – Sun Hydraulics 4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CABGLHN-C2J/S3

C2J Sun Hydraulics Ninety degree with high capacity port 3, accepts standard and weatherized coils Line mount manifold drawing C2J – Sun Hydraulics Ninety degree with high capacity port 3, accepts standard and weatherized coils Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CABGLHN-C2J/S3

RPET-LWN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPET-LWN – Sun Hydraulics Anti-Shock, pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPETLWN-FNT/S3

FNT Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing FNT – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RPETLWN-FNT/S3

RPGE-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RPGE-LAN – Sun Hydraulics Fast-acting, pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPGELAN-CFL/S3

CFL Sun Hydraulics Sandwich mount through port Line mount manifold drawing CFL – Sun Hydraulics Sandwich mount through port Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

RPGELAN-CFL/S3

DFEA8-DN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEA8-DN – Sun Hydraulics 2-way, poppet directional valve with integral T-8A control cavity - control 1-2 - N – Buna-N
Assembly:

DFEA8DN-IEQ/S

IEQ Sun Hydraulics Through port with gauge port Line mount manifold drawing IEQ – Sun Hydraulics Through port with gauge port Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

DFEA8DN-IEQ/S

CBHG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHGLJN-K2S

K2S Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2S – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBHGLJN-K2S

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-EEU/S3

EEU Sun Hydraulics Port 3 connected to port 1 Line mount manifold drawing EEU – Sun Hydraulics Port 3 connected to port 1 Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CACKLHN-EEU/S3

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-BQL/S3

BQL Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold drawing BQL – Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CAEGLGN-BQL/S3

FRBA-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-163A FRBA-XAN – Sun Hydraulics Fixed-orifice, bypass/restrictive, priority, flow control valve - Standard Material/Coating
Assembly:

FRBAXAN-JFB

JFB Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing JFB – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FRBAXAN-JFB

CAGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGGLGN-VTK/S3

VTK Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold drawing VTK – Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CAGGLGN-VTK/S3

CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-E4T

E4T Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing E4T – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACKLHN-E4T

DFDJ-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-5A DFDJ-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series) - No coil
Assembly:

DFDJXCN-XWD

XWD Sun Hydraulics Bidirectional Line mount manifold drawing XWD – Sun Hydraulics Bidirectional Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFDJXCN-XWD

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-H3F/S3

H3F Sun Hydraulics Through port 2 with reverse flow check Line mount manifold drawing H3F – Sun Hydraulics Through port 2 with reverse flow check Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBFLLJN-H3F/S3

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-HCX

HCX Sun Hydraulics Ninety degree Line mount manifold drawing HCX – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGALHN-HCX

DFBF-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DFBF-XCN – Sun Hydraulics FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1 - No coil
Assembly:

DFBFXCN-ACB/S3

ACB Sun Hydraulics Inline Line mount manifold drawing ACB – Sun Hydraulics Inline Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DFBFXCN-ACB/S3

DNDM-LNN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity T-31A DNDM-LNN – Sun Hydraulics 4-way, manually operated, directional spool valve - N – Buna-N
Assembly:

DNDMLNN-MNC

MNC Sun Hydraulics Ninety degree Line mount manifold drawing MNC – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DNDMLNN-MNC

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-H6Y

H6Y Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing H6Y – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFLLJN-H6Y

Back To Shop