Product Price Quantity Total  
PPDB-LAN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-11A PPDB-LAN – Sun Hydraulics Pilot-operated, pressure reducing/relieving valve - Standard Material/Coating
Assembly:

PPDBLAN-A2C

A2C Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2C – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PPDBLAN-A2C

PPDL8-WN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-11A PPDL8-WN – Sun Hydraulics Pilot-operated, pressure reducing/relieving main stage with open transition and integral T-8A control cavity - N – Buna-N
Assembly:

PPDL8WN-A2A

A2A Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2A – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PPDL8WN-A2A

CBAG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAG-LJN – Sun Hydraulics 4.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAGLJN-A7C

A7C Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A7C – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAGLJN-A7C

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-H2M

H2M Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing H2M – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFLLJN-H2M

RVID-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-24A RVID-LAN – Sun Hydraulics Ventable, pilot-operated, balanced piston relief valve with drain to port 4 - Standard Material/Coating
Assembly:

RVIDLAN-Q48

Q48 Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q48 – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RVIDLAN-Q48

FVEA-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-23A FVEA-XAN – Sun Hydraulics Ventable, fixed-orifice, bypass/restrictive, priority flow control valve - Standard Material/Coating
Assembly:

FVEAXAN-P4E

P4E Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing P4E – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FVEAXAN-P4E

DFDI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-5A DFDI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFDIXCN-DAI/S

DAI Sun Hydraulics Ninety degree Line mount manifold drawing DAI – Sun Hydraulics Ninety degree Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

DFDIXCN-DAI/S

DPBM-LAN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-21A DPBM-LAN – Sun Hydraulics 2-way, pilot-operated, directional valve with drain to port 4 - normally open - Standard Material/Coating
Assembly:

DPBMLAN-M4A

M4A Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4A – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DPBMLAN-M4A

RSHS-LAN Sun Hydraulics Sequence Valve – installation dimensions drawing, cavity T-17A RSHS-LAN – Sun Hydraulics Pilot-operated, balanced poppet sequence valve - /AP – Stainless Steel, Passivated
Assembly:

RSHSLAN/AP-BKB

BKB Sun Hydraulics ISO 07: On B, port 3 to A Sandwich manifold drawing BKB – Sun Hydraulics ISO 07: On B, port 3 to A Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RSHSLAN/AP-BKB

RVCK-LJN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RVCK-LJN – Sun Hydraulics FLeX Series 2-stage, solenoid-operated adjustable relief valve, normally vented - No coil
Assembly:

RVCKLJN-CBG

CBG Sun Hydraulics ISO 05: B to T Sandwich manifold drawing CBG – Sun Hydraulics ISO 05: B to T Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RVCKLJN-CBG

RPGS-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RPGS-LAN – Sun Hydraulics Pilot-operated, balanced poppet relief valve - Standard Material/Coating
Assembly:

RPGSLAN-CEH/S5

CEH Sun Hydraulics Through port with gauge port Line mount manifold drawing CEH – Sun Hydraulics Through port with gauge port Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

RPGSLAN-CEH/S5

RPEC-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEC-LAN – Sun Hydraulics Pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPECLAN-VZD

VZD Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross port Motor mount manifold drawing VZD – Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross port Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPECLAN-VZD

PRFR-LAN Sun Hydraulics Reducing Valve – installation dimensions drawing, cavity T-2A PRFR-LAN – Sun Hydraulics Direct-acting, pressure reducing valve - /AP – Stainless Steel, Passivated
Assembly:

PRFRLAN/AP-3BC

3BC Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing 3BC – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PRFRLAN/AP-3BC

PRTS-XDN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity SC-08-03 PRTS-XDN – Sun Hydraulics Electro-proportional, direct-acting pressure reducing/relieving valve with filter screen, 3000 psi (210 bar) - common cavity - 212 – DIN 43650-Form A, 12 VDC
Assembly:

PRTSXDN212-JRC

JRC Sun Hydraulics Ninety degree Line mount manifold drawing JRC – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PRTSXDN212-JRC

PSDP-MDN Sun Hydraulics Reducing/Relieving Valve – installation dimensions drawing, cavity T-21A PSDP-MDN – Sun Hydraulics Electro-proportional, direct-acting, pressure reducing/relieving valve with drain to port 4 - No coil
Assembly:

PSDPMDN-M4I

M4I Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4I – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

PSDPMDN-M4I

DFFI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFFIXCN-LAL

LAL Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing LAL – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFFIXCN-LAL

CWIG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-24A CWIG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWIGLGN-XLM

XLM Sun Hydraulics Cross pilot with common port 4s Line mount manifold drawing XLM – Sun Hydraulics Cross pilot with common port 4s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CWIGLGN-XLM

CBIL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIL-LJN – Sun Hydraulics 2.3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBILLJN-KCX

KCX Sun Hydraulics Ninety degree Line mount manifold drawing KCX – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBILLJN-KCX

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-BAC

BAC Sun Hydraulics Ninety degree with high capacity port 3 Line mount manifold drawing BAC – Sun Hydraulics Ninety degree with high capacity port 3 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCLHN-BAC

RPEC8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEC8-WN – Sun Hydraulics Pilot-operated, balanced piston relief main stage with integral T-8A control cavity - N – Buna-N
Assembly:

RPEC8WN-VCC

VCC Sun Hydraulics Cross port with gauge ports Line mount manifold drawing VCC – Sun Hydraulics Cross port with gauge ports Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPEC8WN-VCC

RPGC-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RPGC-LAN – Sun Hydraulics Pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPGCLAN-CAH

CAH Sun Hydraulics Ninety degree Line mount manifold drawing CAH – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RPGCLAN-CAH

CBFL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFL-LJN – Sun Hydraulics 2.3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFLLJN-ZSD

ZSD Sun Hydraulics Direct mount Line mount manifold drawing ZSD – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFLLJN-ZSD

Back To Shop

Cart totals

Subtotal
Total

Main Menu