RGFA-LCN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RGFA-LCN – Sun Hydraulics Low-pressure-range, direct-acting relief valve - Standard Material/Coating
Assembly:

RGFALCN-ZKA/S4

ZKA Sun Hydraulics Flange mount through port Line mount manifold drawing ZKA – Sun Hydraulics Flange mount through port Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

RGFALCN-ZKA/S4

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-YVV

YVV Sun Hydraulics Direct mount, cross pilot Gasket mount manifold drawing YVV – Sun Hydraulics Direct mount, cross pilot Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEKLHN-YVV

FCFB-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-18A FCFB-XAN – Sun Hydraulics Fixed-orifice pressure compensated flow control valve with reverse flow check - Standard Material/Coating
Assembly:

FCFBXAN-LEE/S3

LEE Sun Hydraulics Through port with gauge port Line mount manifold drawing LEE – Sun Hydraulics Through port with gauge port Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

FCFBXAN-LEE/S3

DKFS-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-22A DKFS-XHN – Sun Hydraulics Normally closed, balanced poppet, logic element - pilot-to-open - Standard Material/Coating
Assembly:

DKFSXHN-W6T/S3

W6T Sun Hydraulics Direct mount Line mount manifold drawing W6T – Sun Hydraulics Direct mount Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DKFSXHN-W6T/S3

DKJS-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-24A DKJS-XHN – Sun Hydraulics Normally closed, balanced poppet, logic element - pilot-to-open - Standard Material/Coating
Assembly:

DKJSXHN-ZEX/Y4

ZEX Sun Hydraulics Direct mount Line mount manifold drawing ZEX – Sun Hydraulics Direct mount Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

DKJSXHN-ZEX/Y4

CNAC-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-162A CNAC-XCN – Sun Hydraulics Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check - Standard Material/Coating
Assembly:

CNACXCN-ABC/S

ABC Sun Hydraulics ISO 02: A and B to T Sandwich manifold drawing ABC – Sun Hydraulics ISO 02: A and B to T Sandwich manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CNACXCN-ABC/S

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-XHW

XHW Sun Hydraulics Inline, cross pilot with shuttle Line mount manifold drawing XHW – Sun Hydraulics Inline, cross pilot with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEGLGN-XHW

CVCV-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-21A CVCV-XCN – Sun Hydraulics Vented pilot-to-open check valve - Standard Material/Coating
Assembly:

CVCVXCN-M4A/S3

M4A Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing M4A – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CVCVXCN-M4A/S3

FSEH-XAN Sun Hydraulics Flow divider-combiner Valve – installation dimensions drawing, cavity T-33A FSEH-XAN – Sun Hydraulics High capacity, closed center, flow divider-combiner valve - N – Buna-N
Assembly:

FSEHXAN-PM5/S5

PM5 Sun Hydraulics Ninety degree Line mount manifold drawing PM5 – Sun Hydraulics Ninety degree Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

FSEHXAN-PM5/S5

CBAA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAA-LHN – Sun Hydraulics 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAALHN-EGB

EGB Sun Hydraulics Ninety degree with shuttle Line mount manifold drawing EGB – Sun Hydraulics Ninety degree with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAALHN-EGB

CNGC-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-16A CNGC-XCN – Sun Hydraulics Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check - Standard Material/Coating
Assembly:

CNGCXCN-VGP

VGP Sun Hydraulics Common port 1 Line mount manifold drawing VGP – Sun Hydraulics Common port 1 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CNGCXCN-VGP

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-ZNC

ZNC Sun Hydraulics Direct mount Line mount manifold drawing ZNC – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABKLHN-ZNC

CWGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGGLGN-VAN/S3

VAN Sun Hydraulics Cross pilot with independent port 4s Line mount manifold drawing VAN – Sun Hydraulics Cross pilot with independent port 4s Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CWGGLGN-VAN/S3

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-WFA/S3

WFA Sun Hydraulics Direct mount, cross pilot Line mount manifold drawing WFA – Sun Hydraulics Direct mount, cross pilot Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CAGALHN-WFA/S3

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-C5K/S4

C5K Sun Hydraulics Through port 1 with gauge port, accepts standard and weatherized coils Line mount manifold drawing C5K – Sun Hydraulics Through port 1 with gauge port, accepts standard and weatherized coils Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CBAAXNN-C5K/S4

CWGK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-23A CWGK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWGKLHN-VAD/S3

VAD Sun Hydraulics Cross pilot with independent port 4s Line mount manifold drawing VAD – Sun Hydraulics Cross pilot with independent port 4s Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CWGKLHN-VAD/S3

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-WZU

WZU Sun Hydraulics Danfoss OMP/OMR: Cross pilot with shuttle Motor mount manifold drawing WZU – Sun Hydraulics Danfoss OMP/OMR: Cross pilot with shuttle Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAAXNN-WZU