Product Price Quantity Total  
FMDG-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-11A FMDG-XCN – Sun Hydraulics Electro-proportional 3-way flow control valve, meter in (740 Series) - No coil
Assembly:

FMDGXCN-A2B

A2B Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2B – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FMDGXCN-A2B

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-YQZ/S

YQZ Sun Hydraulics Four port directional circuit using logic valves, NPT pilot ports Line mount manifold drawing YQZ – Sun Hydraulics Four port directional circuit using logic valves, NPT pilot ports Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CABKLHN-YQZ/S

CBFB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFBLHN-XCN

XCN Sun Hydraulics Cross port with shuttle on port 3s Line mount manifold drawing XCN – Sun Hydraulics Cross port with shuttle on port 3s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBFBLHN-XCN

CNGC-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-16A CNGC-XCN – Sun Hydraulics Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check - Standard Material/Coating
Assembly:

CNGCXCN-IAQ

IAQ Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing IAQ – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CNGCXCN-IAQ

DFEA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - No coil
Assembly:

DFEAXCN-ZFT/S4

ZFT Sun Hydraulics Sandwich mount through port Line mount manifold drawing ZFT – Sun Hydraulics Sandwich mount through port Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

DFEAXCN-ZFT/S4

CSAY-BXN Sun Hydraulics Shuttle Valve – installation dimensions drawing, cavity T-162A CSAY-BXN – Sun Hydraulics Single ball shuttle valve with signal at port 2 - Standard Material/Coating
Assembly:

CSAYBXN-AGA/S4

AGA Sun Hydraulics Ninety degree, ports 1 & 2 through Line mount manifold drawing AGA – Sun Hydraulics Ninety degree, ports 1 & 2 through Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CSAYBXN-AGA/S4

CBZA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-163A CBZA-LHN – Sun Hydraulics 3:1 pilot ratio, counterbalance valve - N – Buna-N
Assembly:

CBZALHN-J6I/S4

J6I Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing J6I – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CBZALHN-J6I/S4

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-A8V/S4

A8V Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A8V – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CBAAXNN-A8V/S4

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-A7C/Y3

A7C Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A7C – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CACALHN-A7C/Y3

RPES8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPES8-WN – Sun Hydraulics Pilot-operated, balanced poppet relief main stage with integral T-8A control cavity - Standard Material/Coating
Assembly:

RPES8WN-FHE/Y3

FHE Sun Hydraulics Cross port with make up checks Line mount manifold drawing FHE – Sun Hydraulics Cross port with make up checks Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

RPES8WN-FHE/Y3

CAIL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAILLGN-YMY

YMY Sun Hydraulics Cross pilot Line mount manifold drawing YMY – Sun Hydraulics Cross pilot Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAILLGN-YMY

Back To Shop

Cart totals

Subtotal
Total

Main Menu