Product Price Quantity Total  
CAGK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAGKLHN-H6E

H6E Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing H6E – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGKLHN-H6E

FKHA-XCN Sun Hydraulics Throttle Valve – installation dimensions drawing, cavity T-24A FKHA-XCN – Sun Hydraulics 2-way, pilot-shifted, proportional throttle - Standard Material/Coating
Assembly:

FKHAXCN-Q4L

Q4L Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4L – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FKHAXCN-Q4L

RGFA-LCN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RGFA-LCN – Sun Hydraulics Low-pressure-range, direct-acting relief valve - Standard Material/Coating
Assembly:

RGFALCN-CAE/S4

CAE Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing CAE – Sun Hydraulics Ninety degree with gauge port Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

RGFALCN-CAE/S4

CABG-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABG-LHN – Sun Hydraulics 4.5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CABGLHN-EQB/Y3

EQB Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold drawing EQB – Sun Hydraulics Cushion lock with make up checks and shuttle Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CABGLHN-EQB/Y3

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-VYV/Y4

VYV Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold drawing VYV – Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBDAXNN-VYV/Y4

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-A7B/Y3

A7B Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A7B – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CACALHN-A7B/Y3

XSCC-XXN Sun Hydraulics Cavity Plug Valve – hydraulic schematic symbol XSCC-XXN – Sun Hydraulics All ports blocked cavity plug - N – Buna-N
Assembly:

XSCCXXN-NPK/S4

NPK Sun Hydraulics Ninety degree Line mount manifold drawing NPK – Sun Hydraulics Ninety degree Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

XSCCXXN-NPK/S4

CAGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGALHN-BKC/W3

BKC Sun Hydraulics ISO 07: On A, port 3 external Sandwich manifold drawing BKC – Sun Hydraulics ISO 07: On A, port 3 external Sandwich manifold - /W3 – 65-45-12 Ductile Iron, Metric, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CAGALHN-BKC/W3

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-B8J

B8J Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold drawing B8J – Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDXXN-B8J

DFFI-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFI-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 (740 Series) - No coil
Assembly:

DFFIXCN-LA6/T

LA6 Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing LA6 – Sun Hydraulics Ninety degree with gauge port Line mount manifold - /T – 65-45-12 Ductile Iron, Metric, Buna-N, Dewatering Oil
Assembly:

DFFIXCN-LA6/T

CAEL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAELLGN-ZNB/S5

ZNB Sun Hydraulics Direct mount Line mount manifold drawing ZNB – Sun Hydraulics Direct mount Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CAELLGN-ZNB/S5

CAGK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAGKLHN-YRN/S3

YRN Sun Hydraulics Four port directional circuit using logic valves, SAE pilot ports Line mount manifold drawing YRN – Sun Hydraulics Four port directional circuit using logic valves, SAE pilot ports Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CAGKLHN-YRN/S3

NFAB-KXN Sun Hydraulics Needle Valve – installation dimensions drawing, cavity T-8A NFAB-KXN – Sun Hydraulics Fully adjustable needle valve - pilot capacity - N – Buna-N
Assembly:

NFABKXN-U5T/T5

U5T Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing U5T – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - /T5 – 65-45-12 Ductile Iron, Metric, Buna-N, Electroless Nickel
Assembly:

NFABKXN-U5T/T5

RPGC-LAN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RPGC-LAN – Sun Hydraulics Pilot-operated, balanced piston relief valve - Standard Material/Coating
Assembly:

RPGCLAN-ZKE/Y4

ZKE Sun Hydraulics Flange mount through port Line mount manifold drawing ZKE – Sun Hydraulics Flange mount through port Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

RPGCLAN-ZKE/Y4

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-E6V/S5

E6V Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing E6V – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CABKLHN-E6V/S5

CBIL-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIL-LJN – Sun Hydraulics 2.3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBILLJN-KGR/Y

KGR Sun Hydraulics Ninety degree with shuttle Line mount manifold drawing KGR – Sun Hydraulics Ninety degree with shuttle Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CBILLJN-KGR/Y

DFBG-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DFBG-XCN – Sun Hydraulics FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1 - No coil
Assembly:

DFBGXCN-AET

AET Sun Hydraulics Through port 1 with gauge port Line mount manifold drawing AET – Sun Hydraulics Through port 1 with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFBGXCN-AET

DFFA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - No coil
Assembly:

DFFAXCN-ZEG/T5

ZEG Sun Hydraulics Direct mount Line mount manifold drawing ZEG – Sun Hydraulics Direct mount Line mount manifold - /T5 – 65-45-12 Ductile Iron, Metric, Buna-N, Electroless Nickel
Assembly:

DFFAXCN-ZEG/T5

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-E6V/S5

E6V Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing E6V – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CBAAXNN-E6V/S5

Back To Shop

Cart totals

Subtotal
Total

Main Menu