Product Price Quantity Total  
DTBF-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DTBF-XCN – Sun Hydraulics FLeX Series 2-way, direct-acting, solenoid-operated directional blocking poppet valve - No coil
Assembly:

DTBFXCN-AGA/S4

AGA Sun Hydraulics Ninety degree, ports 1 & 2 through Line mount manifold drawing AGA – Sun Hydraulics Ninety degree, ports 1 & 2 through Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

DTBFXCN-AGA/S4

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-B6C/Y4

B6C Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing B6C – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBDDXXN-B6C/Y4

RDFA3-AN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-3A RDFA3-AN – Sun Hydraulics Non-adjustable direct-acting relief valve - N – Buna-N
Assembly:

RDFA3AN-ZCC/T5

ZCC Sun Hydraulics Flange mount through port Line mount manifold drawing ZCC – Sun Hydraulics Flange mount through port Line mount manifold - /T5 – 65-45-12 Ductile Iron, Metric, Buna-N, Electroless Nickel
Assembly:

RDFA3AN-ZCC/T5

DOHR-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-23A DOHR-XHN – Sun Hydraulics Normally open, balanced poppet, logic element - vent-to-close - N – Buna-N
Assembly:

DOHRXHN-P4N/Y5

P4N Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing P4N – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

DOHRXHN-P4N/Y5

CXHA-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-16A CXHA-XCN – Sun Hydraulics Free flow nose to side check valve - Standard Material/Coating
Assembly:

CXHAXCN-ZBL/Y5

ZBL Sun Hydraulics Sandwich mount through port Line mount manifold drawing ZBL – Sun Hydraulics Sandwich mount through port Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CXHAXCN-ZBL/Y5

DFCB-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-13A DFCB-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 - No coil
Assembly:

DFCBXCN-WMZ

WMZ Sun Hydraulics Danfoss OMT: Shuttle between A and B, S port external Motor mount manifold drawing WMZ – Sun Hydraulics Danfoss OMT: Shuttle between A and B, S port external Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFCBXCN-WMZ

CBIH-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIH-LJN – Sun Hydraulics 10:1 pilot ratio, standard capacity counterbalance valve - /LH – Mild Steel, Zinc-Nickel
Assembly:

CBIHLJN/LH-BKL

BKL Sun Hydraulics ISO 07: On A, port 3 to B Sandwich manifold drawing BKL – Sun Hydraulics ISO 07: On A, port 3 to B Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBIHLJN/LH-BKL

CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-YTB/Y

YTB Sun Hydraulics Eaton/Char-Lynn 2000: Cross pilot Motor mount manifold drawing YTB – Sun Hydraulics Eaton/Char-Lynn 2000: Cross pilot Motor mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CBDDLJN-YTB/Y

DFBG-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-162A DFBG-XCN – Sun Hydraulics FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1 - No coil
Assembly:

DFBGXCN-ABS/Y

ABS Sun Hydraulics ISO 03 - 30mm: Out of T Sandwich manifold drawing ABS – Sun Hydraulics ISO 03 - 30mm: Out of T Sandwich manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

DFBGXCN-ABS/Y

CNAC-XCN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-162A CNAC-XCN – Sun Hydraulics Fixed-orifice, non-pressure compensated, flow control valve with reverse flow check - Standard Material/Coating
Assembly:

CNACXCN-ABA/W

ABA Sun Hydraulics ISO 02: P to T Sandwich manifold drawing ABA – Sun Hydraulics ISO 02: P to T Sandwich manifold - /W – 65-45-12 Ductile Iron, Metric, Viton, Dewatering Oil
Assembly:

CNACXCN-ABA/W

CBGB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGB-LHN – Sun Hydraulics 1.5:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGBLHN-HNY

HNY Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing HNY – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBGBLHN-HNY

DFFB-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFB-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 - No coil
Assembly:

DFFBXCN-ZEG/Y

ZEG Sun Hydraulics Direct mount Line mount manifold drawing ZEG – Sun Hydraulics Direct mount Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

DFFBXCN-ZEG/Y

CWIL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-24A CWIL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - Standard Material/Coating
Assembly:

CWILLGN-Q4E/Y3

Q4E Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4E – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CWILLGN-Q4E/Y3

C8T Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing C8T – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

DNCAZXN224-C8T/S3

W2A Sun Hydraulics Ninety degree Line mount manifold drawing W2A – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DNCAZXN224-W2A

DFFB-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFB-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 - No coil
Assembly:

DFFBXCN-ZEG/Y5

ZEG Sun Hydraulics Direct mount Line mount manifold drawing ZEG – Sun Hydraulics Direct mount Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

DFFBXCN-ZEG/Y5

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-B5K/Y

B5K Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold drawing B5K – Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold - /Y – 65-45-12 Ductile Iron, Viton, Dewatering Oil
Assembly:

CAEKLHN-B5K/Y

Back To Shop

Cart totals

Subtotal
Total

Main Menu