Product Price Quantity Total  
CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-VYW

VYW Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold drawing VYW – Sun Hydraulics Inline, Direct mount, cross pilot, 2 gasket ports Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCXNN-VYW

RDDA3-AN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RDDA3-AN – Sun Hydraulics Non-adjustable direct-acting relief valve - Standard Material/Coating
Assembly:

RDDA3AN-WVQ

WVQ Sun Hydraulics Danfoss OMP/OMR: Cross port Motor mount manifold drawing WVQ – Sun Hydraulics Danfoss OMP/OMR: Cross port Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RDDA3AN-WVQ

CBHG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHG-LJN – Sun Hydraulics 4.5:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHGLJN-W9E

W9E Sun Hydraulics Direct mount Line mount manifold drawing W9E – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBHGLJN-W9E

CBDC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCLHN-BDB/S5

BDB Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing BDB – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CBDCLHN-BDB/S5

CBDA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDALHN-BDB/S5

BDB Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing BDB – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CBDALHN-BDB/S5

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-BVL

BVL Sun Hydraulics Inline Line mount manifold drawing BVL – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDXXN-BVL

RDDA3-AN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RDDA3-AN – Sun Hydraulics Non-adjustable direct-acting relief valve - Standard Material/Coating
Assembly:

RDDA3AN-VZH

VZH Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross port Motor mount manifold drawing VZH – Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross port Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

RDDA3AN-VZH

CAGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGGLGN-BKQ

BKQ Sun Hydraulics ISO 07: On P, port 3 external Sandwich manifold drawing BKQ – Sun Hydraulics ISO 07: On P, port 3 external Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGGLGN-BKQ

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-ZWS

ZWS Sun Hydraulics Ninety degree Gasket mount manifold drawing ZWS – Sun Hydraulics Ninety degree Gasket mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDXXN-ZWS

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-E5V/S

E5V Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold drawing E5V – Sun Hydraulics Through port 2 with reverse flow check and high capacity port 3 Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CBABXNN-E5V/S

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-EFV/S

EFV Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing EFV – Sun Hydraulics Ninety degree with gauge port Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CBAAXNN-EFV/S

CACH-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACH-LGN – Sun Hydraulics 10:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CACHLGN-V2A

V2A Sun Hydraulics Direct mount Line mount manifold drawing V2A – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACHLGN-V2A

DFEJ-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-16A DFEJ-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 2-1 (740 Series) - No coil
Assembly:

DFEJXCN-ICD

ICD Sun Hydraulics Inline Line mount manifold drawing ICD – Sun Hydraulics Inline Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFEJXCN-ICD

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-BDI

BDI Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing BDI – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEGLGN-BDI

FCDB-XAN Sun Hydraulics Flow Control Valve – installation dimensions drawing, cavity T-5A FCDB-XAN – Sun Hydraulics Fixed-orifice pressure compensated flow control valve with reverse flow check - Standard Material/Coating
Assembly:

FCDBXAN-W8Z

W8Z Sun Hydraulics Direct mount Line mount manifold drawing W8Z – Sun Hydraulics Direct mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FCDBXAN-W8Z

CBDCX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDCX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDCXNN-ZWO

ZWO Sun Hydraulics Ninety degree Line mount manifold drawing ZWO – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDCXNN-ZWO

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-C5B/S

C5B Sun Hydraulics Through port 1 with gauge port, accepts standard and weatherized coils Line mount manifold drawing C5B – Sun Hydraulics Through port 1 with gauge port, accepts standard and weatherized coils Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CABKLHN-C5B/S

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-Z7D

Z7D Sun Hydraulics Direct mount, through port 2 Line mount manifold drawing Z7D – Sun Hydraulics Direct mount, through port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAEGLGN-Z7D

Back To Shop

Cart totals

Subtotal
Total

Main Menu