Product Price Quantity Total  
CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-VWZ/W

VWZ Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross pilot with shuttle Motor mount manifold drawing VWZ – Sun Hydraulics Eaton/Char-Lynn 4000/6000: Cross pilot with shuttle Motor mount manifold - /W – 65-45-12 Ductile Iron, Metric, Viton, Dewatering Oil
Assembly:

CBDBXNN-VWZ/W

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-ZTN/Y5

ZTN Sun Hydraulics Direct mount, cross pilot Gasket mount manifold drawing ZTN – Sun Hydraulics Direct mount, cross pilot Gasket mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CBABXNN-ZTN/Y5

CAEG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAEGLGN-BBE/T4

BBE Sun Hydraulics ISO 05: B to T, port 3 external Sandwich manifold drawing BBE – Sun Hydraulics ISO 05: B to T, port 3 external Sandwich manifold - /T4 – 65-45-12 Ductile Iron, Metric, Buna-N, Chem. Black
Assembly:

CAEGLGN-BBE/T4

CACH-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACH-LGN – Sun Hydraulics 10:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CACHLGN-EPJ/Y5

EPJ Sun Hydraulics Cushion lock with make up checks Line mount manifold drawing EPJ – Sun Hydraulics Cushion lock with make up checks Line mount manifold - /Y5 – 65-45-12 Ductile Iron, Viton, Electroless Nickel
Assembly:

CACHLGN-EPJ/Y5

LOHOZ-DN Sun Hydraulics Position Indication Valve – installation dimensions drawing, cavity T-17A LOHOZ-DN – Sun Hydraulics Pilot-to-close, spring-biased open, unbalanced poppet logic element with position switch - V – Viton
Assembly:

LOHOZDV-BK6

BK6 Sun Hydraulics ISO 07: Sequence out of A with reverse flow check Sandwich manifold drawing BK6 – Sun Hydraulics ISO 07: Sequence out of A with reverse flow check Sandwich manifold - 6061-T651 Aluminum, Buna-N
Assembly:

LOHOZDV-BK6

CAEK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CAEK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CAEKLHN-B7W/S4

B7W Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing B7W – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CAEKLHN-B7W/S4

CBFD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFDLJN-H4D/Y3

H4D Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing H4D – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CBFDLJN-H4D/Y3

CAIL-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CAIL-LGN – Sun Hydraulics 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAILLGN-K66/S3

K66 Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing K66 – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CAILLGN-K66/S3

FKIA-XCN Sun Hydraulics Throttle Valve – installation dimensions drawing, cavity T-24A FKIA-XCN – Sun Hydraulics 2-way, pilot-shifted, proportional throttle, high capacity - /AP – Stainless Steel, Passivated
Assembly:

FKIAXCN/AP-Q4R

Q4R Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing Q4R – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

FKIAXCN/AP-Q4R

CACH-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACH-LGN – Sun Hydraulics 10:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CACHLGN-EMC/Y3

EMC Sun Hydraulics Cushion lock Line mount manifold drawing EMC – Sun Hydraulics Cushion lock Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

CACHLGN-EMC/Y3

CBFB-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFB-LHN – Sun Hydraulics 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFBLHN-WED/Y4

WED Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold drawing WED – Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold - /Y4 – 65-45-12 Ductile Iron, Viton, Chem. Black
Assembly:

CBFBLHN-WED/Y4

Back To Shop

Cart totals

Subtotal
Total

Main Menu