Product Price Quantity Total  
CBIG-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBIG-LJN – Sun Hydraulics 4.5:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBIGLJN-KC6/S4

KC6 Sun Hydraulics Ninety degree Line mount manifold drawing KC6 – Sun Hydraulics Ninety degree Line mount manifold - /S4 – 65-45-12 Ductile Iron, Buna-N, Chem. Black
Assembly:

CBIGLJN-KC6/S4

CBAA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAA-LHN – Sun Hydraulics 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAALHN-EIK/S3

EIK Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold drawing EIK – Sun Hydraulics 2 cylinder sequence, direct acting Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBAALHN-EIK/S3

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-EEU/S3

EEU Sun Hydraulics Port 3 connected to port 1 Line mount manifold drawing EEU – Sun Hydraulics Port 3 connected to port 1 Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBAAXNN-EEU/S3

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-B4V/S3

B4V Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing B4V – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDAXNN-B4V/S3

RPEC8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPEC8-WN – Sun Hydraulics Pilot-operated, balanced piston relief main stage with integral T-8A control cavity - N – Buna-N
Assembly:

RPEC8WN-FNB/Y3

FNB Sun Hydraulics Ninety degree with reverse flow check Line mount manifold drawing FNB – Sun Hydraulics Ninety degree with reverse flow check Line mount manifold - /Y3 – 65-45-12 Ductile Iron, Viton, Trivalent Clear Zinc with Top Sealer
Assembly:

RPEC8WN-FNB/Y3

CXGD-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-16A CXGD-XCN – Sun Hydraulics Free flow side to nose check valve - Standard Material/Coating
Assembly:

CXGDXCN-IE4

IE4 Sun Hydraulics Through port with gauge port Line mount manifold drawing IE4 – Sun Hydraulics Through port with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXGDXCN-IE4

RPES8-WN Sun Hydraulics Relief Valve – installation dimensions drawing, cavity T-10A RPES8-WN – Sun Hydraulics Pilot-operated, balanced poppet relief main stage with integral T-8A control cavity - Standard Material/Coating
Assembly:

RPES8WN-ZDC/Z

ZDC Sun Hydraulics Flange mount through port Line mount manifold drawing ZDC – Sun Hydraulics Flange mount through port Line mount manifold - /Z – 6061-T651 Aluminum, Metric, Viton
Assembly:

RPES8WN-ZDC/Z

CBDD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDLJN-VVX

VVX Sun Hydraulics 3 cylinder sequence, direct acting Line mount manifold drawing VVX – Sun Hydraulics 3 cylinder sequence, direct acting Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDLJN-VVX

CBFC-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFC-LHN – Sun Hydraulics 3:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFCLHN-H2D/S5

H2D Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing H2D – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CBFCLHN-H2D/S5

DKFD-EHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-2A DKFD-EHN – Sun Hydraulics Normally closed, balanced poppet, logic element - vent-to-open - N – Buna-N
Assembly:

DKFDEHN-3BC

3BC Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing 3BC – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DKFDEHN-3BC

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-B3K/S3

B3K Sun Hydraulics Through port 2 with reverse flow check Line mount manifold drawing B3K – Sun Hydraulics Through port 2 with reverse flow check Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBDBXNN-B3K/S3

DOFR-XHN Sun Hydraulics Logic Element Valve – installation dimensions drawing, cavity T-22A DOFR-XHN – Sun Hydraulics Normally open, balanced poppet, logic element - vent-to-close - N – Buna-N
Assembly:

DOFRXHN-N4B

N4B Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing N4B – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DOFRXHN-N4B

NQEB-XAN Sun Hydraulics Air bleed and start-up Valve – installation dimensions drawing, cavity T-3A NQEB-XAN – Sun Hydraulics Air bleed and start-up valve - Standard Material/Coating
Assembly:

NQEBXAN-CAK

CAK Sun Hydraulics Ninety degree Line mount manifold drawing CAK – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

NQEBXAN-CAK

DCFC-XCN Sun Hydraulics 4-way Valve – installation dimensions drawing, cavity T-64A DCFC-XCN – Sun Hydraulics 4-way, 3-position, pilot-to-shift directional valve - Standard Material/Coating
Assembly:

DCFCXCN-QPE

QPE Sun Hydraulics Ninety degree Line mount manifold drawing QPE – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DCFCXCN-QPE

CABN-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABN-LHN – Sun Hydraulics 7:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CABNLHN-A2I

A2I Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold drawing A2I – Sun Hydraulics Ninety degree with reverse flow check, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABNLHN-A2I

CACG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACGLGN-U8E/S3

U8E Sun Hydraulics Danfoss OMS: Cross pilot with shuttle Motor mount manifold drawing U8E – Sun Hydraulics Danfoss OMS: Cross pilot with shuttle Motor mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CACGLGN-U8E/S3

Back To Shop