Product Price Quantity Total  
CACK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACKLHN-W7X/S3

W7X Sun Hydraulics Ninety degree, panel mount Line mount manifold drawing W7X – Sun Hydraulics Ninety degree, panel mount Line mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CACKLHN-W7X/S3

CBFD-LJN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBFD-LJN – Sun Hydraulics 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBFDLJN-WEW/S3

WEW Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold drawing WEW – Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold - /S3 – 65-45-12 Ductile Iron, Buna-N, Trivalent Clear Zinc with Top Sealer
Assembly:

CBFDLJN-WEW/S3

CABK-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABK-LHN – Sun Hydraulics 1:1 pilot ratio, vented counterbalance valve - atmospherically referenced - N – Buna-N
Assembly:

CABKLHN-E2I

E2I Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing E2I – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABKLHN-E2I

CXJC-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-19A CXJC-XCN – Sun Hydraulics Free flow nose to side check valve with port 3 blocked - N – Buna-N
Assembly:

CXJCXCN-K2M

K2M Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K2M – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXJCXCN-K2M

CXGD-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-16A CXGD-XCN – Sun Hydraulics Free flow side to nose check valve - Standard Material/Coating
Assembly:

CXGDXCN-CDO/S5

CDO Sun Hydraulics ISO 08: P to T Sandwich manifold drawing CDO – Sun Hydraulics ISO 08: P to T Sandwich manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

CXGDXCN-CDO/S5

CXDA-XAN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-13A CXDA-XAN – Sun Hydraulics Free flow nose to side check valve - Standard Material/Coating
Assembly:

CXDAXAN-B9I

B9I Sun Hydraulics Bidirectional, accepts standard and weatherized coils Line mount manifold drawing B9I – Sun Hydraulics Bidirectional, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXDAXAN-B9I

CBHA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHALHN-K4E

K4E Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing K4E – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBHALHN-K4E

CXCD-XCN Sun Hydraulics Check Valve – installation dimensions drawing, cavity T-13A CXCD-XCN – Sun Hydraulics Free flow side to nose check valve - Standard Material/Coating
Assembly:

CXCDXCN-B9B

B9B Sun Hydraulics Bidirectional, accepts standard and weatherized coils Line mount manifold drawing B9B – Sun Hydraulics Bidirectional, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CXCDXCN-B9B

DMUQ-XHN Sun Hydraulics 3-way Valve – installation dimensions drawing, cavity SC-10-03 DMUQ-XHN – Sun Hydraulics 3-way, direct-acting, balanced spool, solenoid-operated directional valve, 1600 psi (110 bar) - common cavity - No coil
Assembly:

DMUQXHN-JSD

JSD Sun Hydraulics Ninety degree Line mount manifold drawing JSD – Sun Hydraulics Ninety degree Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DMUQXHN-JSD

CAGG-LGN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CAGG-LGN – Sun Hydraulics 5:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CAGGLGN-H7L

H7L Sun Hydraulics Through port 1 with reverse flow check Line mount manifold drawing H7L – Sun Hydraulics Through port 1 with reverse flow check Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CAGGLGN-H7L

CBDDX-XN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDDX-XN – Sun Hydraulics Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDDXXN-BDA

BDA Sun Hydraulics Port 3 connected to port 2 Line mount manifold drawing BDA – Sun Hydraulics Port 3 connected to port 2 Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDDXXN-BDA

CABN-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABN-LHN – Sun Hydraulics 7:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CABNLHN-E2T/S

E2T Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold drawing E2T – Sun Hydraulics Ninety degree with reverse flow check - reducing Line mount manifold - /S – 65-45-12 Ductile Iron, Buna-N, Dewatering Oil
Assembly:

CABNLHN-E2T/S