Product Price Quantity Total  
DFFA-XCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-18A DFFA-XCN – Sun Hydraulics 2-way, 2-stage, solenoid-operated directional poppet valve - flow 1-2 - 211 – DIN 43650-Form A, 115 VAC
Assembly:

DFFAXCN211-LA7

LA7 Sun Hydraulics Ninety degree with gauge port Line mount manifold drawing LA7 – Sun Hydraulics Ninety degree with gauge port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

DFFAXCN211-LA7

CBAAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBAAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBAAXNN-ZTS

ZTS Sun Hydraulics Nipple mount Line mount manifold drawing ZTS – Sun Hydraulics Nipple mount Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBAAXNN-ZTS

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-BNV

BNV Sun Hydraulics Cushion lock with shuttle Line mount manifold drawing BNV – Sun Hydraulics Cushion lock with shuttle Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-BNV

CBDAX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDAX-NN – Sun Hydraulics Fixed setting, 3:1 pilot ratio, restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDAXNN-XBB

XBB Sun Hydraulics Cross port with shuttle on port 3s Line mount manifold drawing XBB – Sun Hydraulics Cross port with shuttle on port 3s Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDAXNN-XBB

DAAH-BCN Sun Hydraulics 2-way Valve – installation dimensions drawing, cavity T-8A DAAH-BCN – Sun Hydraulics 2-way, hydraulically operated, spool directional valve - pilot capacity - Standard Material/Coating
Assembly:

DAAHBCN-WFN/S5

WFN Sun Hydraulics Ninety degree Line mount manifold drawing WFN – Sun Hydraulics Ninety degree Line mount manifold - /S5 – 65-45-12 Ductile Iron, Buna-N, Electroless Nickel
Assembly:

DAAHBCN-WFN/S5

CACA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CACA-LHN – Sun Hydraulics 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced - Standard Material/Coating
Assembly:

CACALHN-E8I

E8I Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold drawing E8I – Sun Hydraulics 2 cylinder sequence, with reverse checks Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CACALHN-E8I

CBABX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CBABX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBABXNN-C6K

C6K Sun Hydraulics Ninety degree with high capacity port 3, gauge port, accepts standard and weatherized coils Line mount manifold drawing C6K – Sun Hydraulics Ninety degree with high capacity port 3, gauge port, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBABXNN-C6K

CBGA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-17A CBGA-LHN – Sun Hydraulics 3:1 pilot ratio, standard capacity counterbalance valve - Standard Material/Coating
Assembly:

CBGALHN-WED

WED Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold drawing WED – Sun Hydraulics Danfoss OMP/OMR: Priority flow control on P, bypass to T Motor mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBGALHN-WED

CBHA-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-19A CBHA-LHN – Sun Hydraulics 3:1 pilot ratio, restrictive counterbalance valve - N – Buna-N
Assembly:

CBHALHN-VFT

VFT Sun Hydraulics Sandwich mount through port Line mount manifold drawing VFT – Sun Hydraulics Sandwich mount through port Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBHALHN-VFT

CBDBX-NN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-2A CBDBX-NN – Sun Hydraulics Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valve - Standard Material/Coating
Assembly:

CBDBXNN-B6D

B6D Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold drawing B6D – Sun Hydraulics Ninety degree with reverse flow check - sequence Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CBDBXNN-B6D

CABN-LHN Sun Hydraulics Counterbalance Valve – installation dimensions drawing, cavity T-11A CABN-LHN – Sun Hydraulics 7:1 pilot ratio, vented counterbalance - valve atmospherically referenced - Standard Material/Coating
Assembly:

CABNLHN-C3C

C3C Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold drawing C3C – Sun Hydraulics Ninety degree, accepts standard and weatherized coils Line mount manifold - 6061-T651 Aluminum, Buna-N
Assembly:

CABNLHN-C3C

Back To Shop

Cart totals

Subtotal
Total

Main Menu